• Title/Summary/Keyword: drainage method

Search Result 892, Processing Time 0.029 seconds

A Study on Real-Time Operation Method of Urban Drainage System using Data-Driven Estimation (실시간 자료지향형 예측을 활용한 내배수 시설 운영기법 연구)

  • Son, Ahlong;Kim, Byunghyun;Han, Kunyeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.949-963
    • /
    • 2017
  • This study present an efficient way of operating drainage pump station as part of nonstructural measures for reducing urban flood damage. The water level in the drainage pump station was forecast using Neuro-Fuzzy and then operation rule of the drainage pump station was determined applying the genetic algorithm method based on the predicted inner water level. In order to reflect the topographical characteristics of the drainage area when constructing the Neuro-Fuzzy model, the model considering spatial parameters was developed. Also, the model was applied a penalty type of genetic algorithm so as to prevent repeated stops and operations while lowering my highest water level. The applicability of the development model for the five drainage pump stations in the Mapo drainage area was verified. It is considered to be able to effectively manage urban drainage facilities in the development of these operating rules.

A Study on Hardening Zone by Vacuum Consolidation Drainage Method (진공압밀 배수공법에 의한 Hardening Zone에 대한 연구)

  • Chung, Youn-In;Kim, Hee-Joong;Chang, Chun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.197-205
    • /
    • 2004
  • The relationships were studied between the range of hardening zone and the intensity of vacuum pressure in case of applying vacuum consolidation drainage method for soil improvement. A testing apparatus was made to measure the range of hardening zone varying the water content and the intensity of vacuum pressure for 3 different the highly compressible dredged clays(Gwangyang, Busan and Mokpo). In case of applying high vacuum pressure, the hardening zone is not spreaded as compared to low vacuum pressure because of the clogging of drainage and developed hardening zone near the drainage.

An Analysis of Irrigation and Drainage Characteristics at Large-Sized Paddy Fields Using a Two-Dimensional Numerical Model (2차원 유한체적 수치모형을 이용한 대구획 논의 용배수 특성해석(관개배수 \circled2))

  • 박종민;박승우;강문성;강민구
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.162-168
    • /
    • 2000
  • A two-dimensional numerical model based on a finite volume method was formulated to solve the shallow water equations and applied for evaluating irrigation and drainage characteristics at large-sized paddy fields. Manning roughness coefficient was calibrated using the observed inundating depths at drainage tests and used for validating the model with the results from irrigation and drainage test. The simulated results were in good agreement with the observed inundating depths.

  • PDF

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

The Estimation of Horizontal Coefficient of Consolidation Using Velocity Method (Velocity Method를 이용한 수평압밀계수 산정에 관한 연구)

  • 김지용;천홍래;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.475-480
    • /
    • 2000
  • This study was to present the method for estimating the horizontal coefficient of consolidation by using velocity method which was based on the Barren's equation. Horizontal drainage consolidation tests, including a radial drainage consolidation test, a cylindrical consolidation test, and a large soil box test, were performed to examine its validity. Using the velocity method, horizontal coefficient of consolidation was calculated and compared with lost method, √t method, Magnan & Deroy's method, Bergado's method.

  • PDF

Application Time of Irrigation Management by Drainage Level Sensor in Tomato Perlite Bag Culture (토마토 펄라이트 자루재배시 배액전극제어법 적용시점 구명)

  • Kim, Sung-Eun;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The experiment was implemented to introduce the drainage electrode irrigation system as early as possible after transplanting in order to save the nutrient solution in a convenient way. Drainage electrode irrigation method was introduced 15, 19 or 22 days after transplanting after irrigation was firstly controlled by time clock. Time clock method was also treated as a control plot. Drainage electrode method could be adopted from 15 days after transplanting, 15 days earlier than the present introducing time. The growth and yield was better in treatments with drainage electrode method. Water and fertilizer use efficiency were the highest in the treatment of 15 days, the lowest in time clock treatment.

Evaluation of DEM-based Channel Network Delineation Methods on Watershed Drainage System (DEM을 이용한 수로망 산정 기법에 따른 유역의 배수구조 평가)

  • Lee, Gi Ha;Yoon, Eui Hyeok;Kim, Joo Cheol;Jung, Kwan Sue
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1B
    • /
    • pp.1-11
    • /
    • 2011
  • Channel network delineation from DEM (Digital Elevation Model) is a fundamental pre-process for hydrologic model application since it determines the drainage system in a watershed. This study aims to propose an effective and efficient channel network delineation process and assess the effects of DEM-based channel networks on the watershed drainage system. For these objectives, we applied two methods to generate the channel networks of the Jinan-cheon catchment with $18.28km^2$ from the 20 m resolution DEM: a widely-used area-threshold method and a slope-area threshold method based on the relationship between contributing areas and local slopes. The results showed that the area-threshold method led to unreliable drainage system, which did not satisfy geomorphological laws with respect to drainage density and source area representation whereas the slope-area threshold method provided acceptable results under the geomorphological laws. Our suggestions in this study can give valuable pre-processing information in DEM-based hydrologic modeling.

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(2) Rapid Potential-Controlled Rectifier (직류전기철도 전식대책 실증실험(2) 속응형 정전위 정류기)

  • Ha, Yoon-Cheol;Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.217-219
    • /
    • 2007
  • With the wide spread of direct current(DC) electric railroads in Korea, the stray current or leakage currents from negative return rails become a pending problem to the safety of nearby underground Infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). This method, however, inherently possesses some drawbacks such as an increase of total leakage torrents from rails, expansion of interference zone, etc. In order to resolve these drawbacks, we developed a rapid potential-controled rectifier and applied to a depot area where stray current inference is very severe. The effect of this method was analyzed from the field tell data and we suggest this method can be an excellent alternative to the drainage-bond-based mitigation methods.

  • PDF

A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

An Experiment for the Lay out Method of Mole Drains and the Effect of Desalinization in Reclaimed Tidelands. (간척지에서 두더지 암반설치법과 제감효과에 관한 연구)

  • 정두호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.4
    • /
    • pp.1803-1809
    • /
    • 1969
  • The newly designed mole drainage plower which is attached to tractor is tested for work capacity comparing with the pulling by man animal and winch. Besides. the effect of desalinization by the mole drainage in reclaimed tideland was observed. The results as obtained in this experiment are as follows: 1. The mole drainage plower of tractor attachment has higher work capacity by 3 to 5 times than that of winch 2. The suitable soil moisture content to carry out the layout of mole drains is from 21 to 25 percent. 3. The new design mole drainage plower requires th lowest cost as comparing with the other methods. 4. Carrying out the mole drainage in reclaimed tideland it is effective in desalinization from 2 to 3 times than the only use of irrigation water. 5. The reasonable depth and interval of mole drains may be 60cm and 3m respectively. 6. The desalinization by the mole drainage increases the yield of rice from 40 to 45 percent in reclaimed tideland.

  • PDF