• Title/Summary/Keyword: disk-type

Search Result 927, Processing Time 0.026 seconds

Optimizing Garbage Collection Overhead of Host-level Flash Translation Layer for Journaling Filesystems

  • Son, Sehee;Ahn, Sungyong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.27-35
    • /
    • 2021
  • NAND flash memory-based SSD needs an internal software, Flash Translation Layer(FTL) to provide traditional block device interface to the host because of its physical constraints, such as erase-before-write and large erase block. However, because useful host-side information cannot be delivered to FTL through the narrow block device interface, SSDs suffer from a variety of problems such as increasing garbage collection overhead, large tail-latency, and unpredictable I/O latency. Otherwise, the new type of SSD, open-channel SSD exposes the internal structure of SSD to the host so that underlying NAND flash memory can be managed directly by the host-level FTL. Especially, I/O data classification by using host-side information can achieve the reduction of garbage collection overhead. In this paper, we propose a new scheme to reduce garbage collection overhead of open-channel SSD by separating the journal from other file data for the journaling filesystem. Because journal has different lifespan with other file data, the Write Amplification Factor (WAF) caused by garbage collection can be reduced. The proposed scheme is implemented by modifying the host-level FTL of Linux and evaluated with both Fio and Filebench. According to the experiment results, the proposed scheme improves I/O performance by 46%~50% while reducing the WAF of open-channel SSDs by more than 33% compared to the previous one.

Toxin Genes and Antimicrobial Resistance of Clostridium perfringens Strains Isolated from Commercial Jeotgals (시판 젓갈에서 분리한 Clostridium perfringens의 독소 유전자 및 항균제 내성 분석)

  • Shin-Hye Lee;Kwon-Sam Park
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.6
    • /
    • pp.826-832
    • /
    • 2023
  • Clostridium perfringens causes diarrhea and other diseases in humans and animals. We investigated the prevalence, toxin gene profiles, and antimicrobial resistance of C. perfringens isolated from commercial jeotgal sample. C. perfringens was isolated from 11 of 22 commercial jeotgals. All C. perfringens strains were positive for the alpha toxin gene, but not for the beta, epsilon, iota, CPE or NetB toxin genes; therefore, all strains were identified as type A C. perfringens. However, the beta2 toxin gene was identified in 54.5% of isolates. Disk diffusion susceptibility tests showed that most isolates were resistant to kanamycin (90.9%), nalidixic acid (72.7%), oxacillin (54.5%), erythromycin (27.3%), ciprofloxacin (9.1%) and clindamycin (9.1%). However, all strains were susceptible to 14 other antimicrobial including amoxicillin, ampicillin, and chloramphenicol. The average minimum inhibitory concentrations against C. perfringens of clindamycin, kanamycin, and nalidixic acid were 128.0, 128.0, and 54.0 ㎍/mL, respectively. These results provide new insight into the necessity for sanitation of commercial jeotgal, and provide evidence to help reduce the risk of contamination with antimicrobial-resistant bacteria.

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

Sanitizing Agent Effect and Antibiotic Resistance of Salmonella spp. Isolated from Raw Chicken Carcasses in Food Service (집단급식용 생계육에서 분리된 Salmonella의 항생체 내성과 위생 처리제의 영향)

  • Kang, Ji-Hyun;Lee, Young-Duck;Jung, Ki-Chang;Park, Jong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.582-588
    • /
    • 2001
  • To control the growth of Salmonella on raw chicken supplied in food service, they were isolated and analysed for their physiological characteristics. Total viable microbe counts under the skin of the chicken amounted to 10% of numbers on their skin. Fifty one of Salmonella were isolated and identified from 75 chicken carcass samples. About 70% of the isolates showed resistance to more than four antibiotics, which indicated very high resistance among the strains ever reported in Korea. Lactic acid and trisodium phosphate(TSP) as sanitizing agent were applied to the Salmonella spp. isolates by agar diffusion method. The resistance by isolates to those sanitizing agents was compared with type strains of S. typhimurium ATCC 14028, S. typhimurium ATCC 12023, S. heidelberg and S. enteritidis. The isolates showed similar or less resistance to the type strains as for the lactic acid. However, as for trisodium phosphate known recently as a good sanitizer, 50% of the isolates showed more resistant compared with the type strains. Also, the treatment time and regeneration medium affected significantly the resistance of the isolates, which indicates that more careful test might be needed for TSP's practical application to raw chicken. Therefore, From the results, it is suggested that antibiotic treatment during breeding broiler and contamination after slaughtering should be minimized along with careful use of sanitizing agent in order to ensure more safe raw chicken supply.

  • PDF

Apical foramen morphology according to the length of merged canal at the apex

  • Kim, Hee-Ho;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • Objectives: The aim of this study was to investigate the relationship between the apical foramen morphology and the length of merged canal at the apex in type II root canal system. Materials and Methods: This study included intact extracted maxillary and mandibular human premolars (n = 20) with fully formed roots without any visible signs of external resorption. The root segments were obtained by removing the crown 1 mm beneath the cementum-enamel junction (CEJ) using a rotary diamond disk. The distance between the file tip and merged point of joining two canals was defined as Lj. The roots were carefully sectioned at 1 mm from the apex by a slow-speed water-cooled diamond saw. All cross sections were examined under the microscope at ${\times}50$ magnification and photographed to estimate the shape of the apical foramen. The longest and the shortest diameter of apical foramen was measured using ImageJ program (1.44p, National Institutes of Health). Correlation coefficient was calculated to identify the link between Lj and the apical foramen shape by Pearson's correlation. Results: The average value of Lj was 3.74 mm. The average of proportion (P), estimated by dividing the longest diameter into the shortest diameter of the apical foramen, was 3.64. This study showed a significant negative correlation between P and Lj (p < 0.05). Conclusions: As Lj gets longer, the apical foramen becomes more ovally shaped. Likewise, as it gets shorter, the apical foramen becomes more flat shaped.

The Study on the Performance Characteristics due to the Degree of Superheat in $NH_3$ Refrigeration System III - The Comparison of Heat Exchanger Types -

  • Hong Suck-Ju;Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Because the usage of CFC and HCFC based refrigerants are restricted due to the depletion of ozone layer, the $NH_3$ gas, in the experiment is evaluated to the performance characteristics for the superheat control to improve the energy efficiency. The experiment is carried out about the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa through the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result, in the case of shell and tube type of heat exchanger, the COP is more efficient than other cases at the degree of superheat $1^{\circ}C$ at each condensing pressure. In the case of shell and disk type of heat exchanger, the COP is the most efficient at the degree of superheat 0.

Recycling of Safety Check Valves Contaminated with Radioactivity by Chemical Decontamination (化學除染에 의한 逆止밸브의 再使用)

  • 정종헌;최왕규;원휘준;심준보;오원진
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2001
  • Chemical decontamination techniques have been employed to reuse the high cost check valves contaminated with radioactivity and to reduce the radiation exposure during the inspection and maintenance work of safety injection system containing check valves. After chemical decontamination, an ultrasonic treatment was conducted to remove the fine solid particles retained in the crevices of check valves. The decontamination process conditions and the amount of chemical reagents were determined from the results of a pre-test, using the (list arm holder. The decontamination factors (DF), estimated from the activity in the solution, ranged from 14.5 to 18.5 corresponding to the activity removal of 93-95ft. The corrosion test data indicated that the general corrosion rate during a chemical decontamination-ultrasonic treatment process are low for type 304 S tainless steel, Inconel -600 and Stellite-6 materials $ (2.1\times10^{-2}$ $6.0\times10^{-2}$ and$ 1.7\times10^{-2}$ mil, respectively).

  • PDF

Study of the geometry of the flow path of a Pressure Reducing Valve to Suppress the Cavitations (캐비테이션 억제를 위한 감압밸브의 유로 형상에 관한 연구)

  • Park, Woo-Cheul;Kim, Il-Gyum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2015
  • This study examined the relationship between the shape of the inside of the PRV and the cavitation of the water supply system of an apartment house. In this paper, nine types of PRV with different gaps and shapes were analyzed numerically using a 3D model embedded in the commercial code, ANSYS-CFX. The lowest pressure and the maximum velocity occurred at the narrow gap, which is located at the between the stem and the disk. When the gap size was increased, the vapor volume fraction was always greater than 0, but the vapor volume fraction of the type of expansion pipe approached 0. These results indicate that the cavitation of PRV can be reduced by a shape change to the type of expansion pipe.

Characteristics of Disc-Type V2O5 Catalyst Impregnated Ceramic Filters for NOx Removal (질소산화물 제거를 위한 디스크형 바나디아 촉매담지 세라믹필터의 특성)

  • 홍민선;문수호;이재춘;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.451-463
    • /
    • 2004
  • The performance of disk-type catalytic filters impregnated by TiO$_2$ or TiO$_2$-3Al$_2$O$_3$ㆍ 2SiO$_2$ supports and V$_2$O$_{5}$ catalyst was evaluated for selective catalytic reduction (SCR) of NO with ammonia as a reductant. XRD, FT -IR, BET and SEM were used to characterize the catalytic filters prepared in this work. Optimal V$_2$O$_{5}$ loading and reaction temperature for V$_2$O$_{5}$/TiO$_2$ catalytic filters were 3-6 wt.% and 350-40$0^{\circ}C$ at GHSV 14,300 $hr^{-1}$ in the presence of oxygen, respectively. With increasing the V$_2$O$_{5}$ loading from 0.5 to 6 wt%, NO conversion increased from 24 to 96% at 40$0^{\circ}C$ and 14.300$hr^{-1}$, and maintained at 80% over in the V$_2$O$_{5}$ loading range of 3-6 wt.% and then dropped at V$_2$O$_{5}$ loading of 7wt.% over. In comparing V$_2$O$_{5}$/ TiO$_2$ and V$_2$O$_{5}$/ TiO$_2$-3Al$_2$O$_3$ㆍ2SiO$_2$ catalytic fillers, which have same 3wt.% V$_2$O$_{5}$ loading, the V$_2$O$_{5}$/ TiO$_2$-3A1$_2$O$_3$ㆍ2SiO$_2$ catalytic filter showed higher activity than V$_2$O$_{5}$/ TiO$_2$ catalytic filter, but higher differential pressure drops owing to its low air permeability. low air permeability.

Relations between Clinical Findings and Treatment Results in Patients with Temporomandibular Disorders (측두하악장애환자의 임상양태와 치료결과와의 관계)

  • Hee-Young Oh;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.407-420
    • /
    • 1995
  • This study was performed to evaluate and compare conservative treatment results by several parameters such as age, sex, symptom duration, type and timing of joint sound, parafunctional habits, splint type, and diagnostic classification. There have been too many articles reporting long term results of conservative treatment but articles related to comparison of treatment results by patients' self-evaluation have been rarely reported. For this study 258 patients with temporomandibular disorders(TMDs) were selected and examined by routine diagnostic procedure for TMDs. The subjects were classified into 5 TMDs subgroups ad treated with conservative treatments involving splints, physical modalities, jaw exercises, and counseling. Visual analogue scale(VAS) about pain, joint sound, and mouth opening limitation was recorded respectively during treatment period. From the VAS data and treatment duration, VAS treatment index(VAS Ti) was calculated. The obtained results were as follows : 1. Pain was the most frequent main symptom in subjects with temporomandibular disorders, and main symptom for mouth opening limitation was comparatively less than for pain or sound in disk displacement with reduction group or in degenerative joint disease group. 2. Degenerative joint disease group had the most poor treatment results and highest occlusal index of Helkim's index. 3. Good prognosis for conservative treatment was observed in acute group, under 6 months than chronic group, 6months over in symptom duration, and subjects with 40 years over in age showed the most poor prognosis. 4. Subjects treated with anterior repositioning splint had better treatment results than subjects treated with centric relation splint, but statistical significance in VAS Ti and treatment duration was not observed. 5. Treatment results according to affected side, types and point of joint sound did not show consistent statistical results. 6. The result for conservative treatment was observed poor in subjects with bruxism and clenching. 7. In studying coincidence between preferred chewing and affected side, frequency of preferred chewing side, in unilateral affection, was higher in ipsilateral than in contralateral side.

  • PDF