• Title/Summary/Keyword: discharge resistance

Search Result 498, Processing Time 0.028 seconds

Chemical resistance of Non-Sintered Cement Mortar using Inorganic Industrial Wastes as activator (무기계 산업폐기물을 자극제로 이용한 비소성 시멘트 모르타르의 내화학성)

  • Mun Kyoung Ju;Lee Chol Woong;Park Won Chun;Soh Yang Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.607-610
    • /
    • 2005
  • If cement can be manufactured with industrial byproducts such as granulated blast furnace slag(GBFS), phosphogypsum(PG), and waste lime(WL) instead of clinker as its counterproposal, there would be many advantages, including maximum use of these industrial byproducts for high value-added resources, conservation of natural resources and energy by omitting the use of clinker, minimized environmental pollution problems caused by $CO_2$ discharge, and reduction of the production cost. This research investigates the chemical resistance of NSC mortar added PG and WL to GBFS as sulfate and alkali activators. The result of experiment of chemical resistance, showed that NSC is very excellent in acid resistance and seawater resistanc. Such a reasons are that the hydrate like CSH gel and ettringite formed dense pore structure of NSC matrix.

  • PDF

Resistance Factors and Relationships for Measurements in Fluvial Rivers (충적하천 실측자료의 저항계수와 관계식)

  • Lee, Jong-Seok;Julien, Pierre Y.
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.445-452
    • /
    • 2012
  • This study is used to analyze the distribution of resistance factors and the relationships of flow resistance with the field measurements which consist of the total 2,604 rivers for 1,865 bed material in natural channels and 739 vegetation in vegetated channels. Resistance factor relationships and distribution range of Manning roughness coefficients and Darcy-Weisbach friction coefficients by the regression analysis are derived from the power law form as a function of flow discharge and friction slope with bed materials and vegetations in natural and vegetated rivers, respectively.

Effects of Particle Size of $Al(OH)_3$ on the Electrical Properties of Silicone Rubber ($Al(OH)_3$의 입자크기에 따른 실리콘 고무의 전기적 특성 연구)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Na, Moon-Kyong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1936-1938
    • /
    • 2005
  • $Al(OH)_3$ is added to the silicone rubber for improvement of its resistance against surface discharge. In this paper, four kinds of $Al(OH)_3$ were added to the SIR during compounding. SIR was deteriorated by a corona treatment. Hydrophobicity recovery rate after corona treatment and arc resistance of SIR were investigated. Hydrophobicity recovery rate of SIR was evaluated by the measurement of contact angle. Arc resistance was evaluated by measuring weight loss of SIR after arc resistance test.

  • PDF

Durability of Cation Exchange Membrane Containing Psf (polysulfone) in the All-vanadium Redox Flow Battery (Psf (polysulfone) 함유 양이온교환막의 바나듐 레독스-흐름 전지에서의 내구성)

  • Kim, Joeng-Geun;Kim, Jae-Chul;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The cation exchange membrane using TPA (tungstophosphoric acid) and the block co-polymer of polysulfone and polyphenylenesulfidesulfone was prepared for a separator of all-vanadium redox flow battery. The membrane resistance of the prepared cation exchange membrane in 1mol/L $H_2SO_4$ aqueous solution was measured. The membrane resistance of the prepared Psf-PPSS and Psf-TPA-PPSS cation exchange membrane was about $0.94{\Omega}{\cdot}cm^2$. Electrochemical property of all-vanadium redox flow battery using the prepared cation exchange membrane was measured. The measured charge-discharge cell resistance of V-RFB at 4 A decreased in the order; Nafion117 < Psf-TPA-PPSS < Psf-PPSS. The durability of membrane was earried out by soaking it in $VO_2{^+}$ solution and evaluated by measuring the charge-discharge cell resistance of V-RFB with an increase of soaking time. The prepared Psf-PPSS cation exchange membrane had high durability and Psf-TPA-PPSS cation exchange membrane had almost same durability compared with Nafion117.

Characteristics and Antimicrobial Resistance Patterns of Staphylococcus aureus Isolated from Horse (국내 말에서 분리된 Staphylococcus aureus의 특성 및 약제 내성 양상)

  • Choi, Seong-Kyoon;Cho, Gil-Jae
    • Journal of Life Science
    • /
    • v.18 no.1
    • /
    • pp.69-74
    • /
    • 2008
  • This study carried out to investigate the antimicrobial resistance and biochemical characteristics of Staphylococcus aureus (S. aureus) isolated from reproductive and respiratory tract in Thoroughbred horse. The specimens were collected from equine vaginal mucosa and upper respiratory tract from March to December 2006 using a culture swab in Korea. S. aureus suspected colonies on blood agar plates were selected and identified as standard biochemical tests and PCR (Applied Biosystems, USA). Antimicrobial resistance test of S. aureus isolates was performed with 30 antimicrobial agents (BBL, USA) by using the agar disk diffusion method. S. aureus isolates were isolated 58 (39.2%) strains of 148 samples: wound 64.7% (11/17), genital discharge 37.0% (37/100) and nasal discharge 32.2% (10/31). Almost isolates showed high resistance to spectinomycin, sulfonamides, erythromycin, tetracyelin, ciprofloxacin and penicillin. These results may provide the basic information to establish strategies for treatment and prevention of reproductive and respiratory disease in Thoroughbred horses in Korea.

Expansion Ratio and Ultimate Load of Pulse-Discharge Bulbed Anchors (펄스방전 그라운드 앵커의 확공특성 및 극한인발력에 관한 연구)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Joo, Yong-Sun;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.7
    • /
    • pp.5-10
    • /
    • 2009
  • The ground anchor is not usually used in soft clay and loose sand, because the pullout resistance of anchors can not be guaranteed. However, there is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which are also known as pulse discharge and electric-spark technologies. The pulse-discharge anchor has a bulbed (or underreamed) bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. In this study, in order to define a relation between expansion rate of the anchor diameter and ultimate load, anchor load tests were carried out in accordance with testing procedures by AASHTO (AASHTO 1990) and FHWA (Weatheb 1998). And then several anchors were exhumed to measure the diameter of the pulse discharge anchors.

Development and Applicability of Discharge Capacity Testing Apparatus Using Penetration Method (관입식 복합 통수능 시험기의 개발과 적용성)

  • Yoo, Nam Jae;Kim, Dong Gun;Park, Byung Soo;Jun, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.313-320
    • /
    • 2008
  • The discharge capacity testing apparatus using penetration method, being able to simulate in laboratory the condition of embedding plastic board drains in field, was developed to investigate consolidation characteristics of ground and to figure out discharge capacity of drains. The developed apparatus with a mandrel and penetrating device was designed to insert PBD into the ground prepared by previously applied pressure, being different from the conventional testing method that the drain was installed and the ground material was poured subsequently. Discharge capacity tests with the conventional apparatus as well as the newly developed one were performed to assess the applicability of the latter. As a result of tests, the conventional method showed delayed consolidation due to overall disturbance of ground and local deformation of drain caused by inhomogeneity of ground. Therefore discharge capacity of drain with the conventional apparatus was measured more or less larger than the expected values whereas discharge capacity with new one could be measured similar to the actual value in field.

RELEVANCE OF BAND DRAIN QUALITY TO EFFECTIVENESS OF GROUND IMPROVEMENT (밴드 드레인의 품질과 연약지반개량효과와의 관련)

  • 김상규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1995.10a
    • /
    • pp.1.3-20
    • /
    • 1995
  • The use of band drains for ground improvement has been increased throughout the world during the past 15 years. Apart from other ground improvement techniques, the quality of band drains affects greatly the well resistance of drains, discharge capacity and clogginf tests for four drains selected are carried out and quality is examined.

  • PDF

Mixed-Mode Transient Analysis of CDM ESD Phenomena (CDM ESD 현상의 혼합모드 과도해석)

  • Choe, Jin-Yeong;Song, Gwang-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.155-165
    • /
    • 2001
  • By suggesting a mixed-mode transient simulation method utilizing a 2-dimensional device simulator, we have analyzed CDM ESD Phenomena in CMOS chips, which utilize NMOS transistors as ESD protection devices. By analyzing the simulation results, the mechanisms leading to device failures in CDM discharge and the differences in discharge characteristics with different polarities of stored charges have been explained in detail. The effects of changes in interconnection resistance values on the gate-oxide failure at input buffers, which is the most serious problem in CDM discharge, have been examined. Also improvements in discharge characteristics with addition of the NMOS transistor for input-buffer protection have been examined.

  • PDF

A Study on Drainage Performance of Domestic Plastic Board Drains and Recovery of Discharge Capacity by Vacuum Effect (국내 PBD재의 배수성능과 진공효과에 의한 통수능력 향상에 관한 연구)

  • 박영목
    • Geotechnical Engineering
    • /
    • v.13 no.2
    • /
    • pp.39-54
    • /
    • 1997
  • Laboratory testings were carried out on plastic board drains (PBDs) using large scale test apparatus to evaluate the physical properties and the drainage performance. The test results reveal that the domestic products of PBDs are well compared with the foreign prod acts as far as the quality and drainage performance are concerned. It has also been confirmed that the discharge capacity decreases with time in such a way that the air bubbles are entrapped inside kinky PBDs and these air bubbles block the water flow through PBDs. It has been found that the vacuum pressure iseffectively applicable to recover the discharge capacity affected by the entrapped air bubbles.

  • PDF