• Title/Summary/Keyword: discharge gate

Search Result 163, Processing Time 0.023 seconds

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs (PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구)

  • 염정덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.6
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

An Improvement of the Gas Discharge Structure of the AMD Gate PDP (AND Gate PDP의 기체방전구조 개선)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.42-47
    • /
    • 2004
  • This research has improved the problem of discharge AND gate PDP proposed before. The polarity of the DC discharge which composes AND gate is reversely designed and the cross talk problem to the adjacent scanning electrode has been improved. The AND gate proposed before operated by using non-linearity of the discharge by the space charge. In this research, new discharge NOT logic in which it was used that an applied voltage changed with the discharge circuit was added to AND gate. AND gate came to operate more stably. A selective address was able to be discharged with four horizontal scanning electrodes from the experiment result. The operation margin of the AND gate discharge obtained 34V and of the address discharge obtained 70V.

A Study on the New Discharge Logic Device for the Plasma Display Panels (플라즈마 디스플레이 패널을 위한 새로운 방전 논리소자에 관한 연구)

  • 염정덕;정영철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2002
  • The plasma display panel with the electrode structure of new discharge AND gate was proposed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8${\mu}\textrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore it is possible to app1y to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

Discharge Coeficient Analysis according to Flow Condition for Radial Gate Type (Radial Gate 형식의 배수갑문 흐름조건별 유량계수 검토)

  • Park, Yeong-Wook;Hwang, Bo-Yeon;Song, Hyun-Gu
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.306-312
    • /
    • 2005
  • Gates for the purpose of drainage are classified following the types of structure as: Radial Gate, Sluice Gate, Rolling Gate, Drum Gate. In many cases of the reclamation project the sluice type of gates are applied. Different from this general trend, however the radial type of gate was adopted in the Saemangeum project. In this case the discharge coefficients which are used for the sluice type of gate was applied. To estimate the correct amount of discharge which will be evacuated through the gates, therefore the proper discharge coefficients should be estimated before the operation of the gates. The discharge coefficients were estimated through the physical hydraulic modeling, and we got the results as: $0.72{\sim}0.84$ for the submerged condition on the both sides of upstream and downstream, $0.62{\sim}0.83$ for the free surface condition on the downtream side only, and $1.04{\sim}1.12$ for the free surface condition on the both sides of upstream and downstream. The discharge coefficients obtained from the experiments are greater than those of the sluice gates in the design criteria. From the results of the study we may expect that in the Saemangeum project the radial gates could evacuate larger amount of discharge than the originally designed discharge, so that we may sure that the Saemangeum gates have enough capability to control the evacuation of water not only in the usual period but also in the flooding season.

  • PDF

Discharge Characteristics of Logic Gate for Discharge Logic Gate Plasma Display Panel (방전 논리게이트 플라즈마 디스플레이 패널의 논리게이트 방전특성)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.9-15
    • /
    • 2005
  • In this research the discharge characteristics of logic gate of the discharge logic gate plasma display panel with the NOT-AND logic function newly designed was analyzed. As for this discharge logic gate a logical output is induced by controlling the voltage between the electrodes using the discharge path. From the experimental result the discharge characteristics of logic gate is influenced by the interrelation of the voltages appling two vertical electrodes. To in the application possibility to large screen PDP, the discharge characteristics by the line resistance of the electrode was evaluated In result it has been inferred that the influence which the drop of voltage by the line resistance of two vertical electrodes exerts on the discharge of the logic gate is minute. Through the experiment, the optimized values of the pulse voltages and the current limitation resistances of each electrode which composed the discharge logic gate were obtained and maximum operation margin of 49[V] was obtained.

A Study on the Characteristics of Floating Discharge in the AND Gate PDP (AND Gate PDP의 Floating 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.22-27
    • /
    • 2004
  • The gas discharge AND gate which have been newly proposed is applied to three electrode surface discharge AC PDP. The address discharge characteristics by the DC-AC floating discharge by which Y electrode is made floating electrode is analyzed The address discharge can be begun by using the floating discharge from the experiment result Moreover, the display discharge can be sustained. The DC priming discharge that the floating discharge is matched to timing is generated in a supplementary electrode. As a result, space charge is supplied enough to the space of the floating discharge and the data voltage is lowered up to l00(V). Driving method to use this DC-AC floating discharge is able to obtain the address operation margin of l00(V).

A Numerical Simulations on the Flow over Ogee Spillway with Tainter Gate (테인터수문이 설치된 월류형 여수로에서의 흐름에 대한 수치모의)

  • Kim, Dae-Geun;Park, Jae-Hyun;Lee, Jae-Hyung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.675-685
    • /
    • 2004
  • In this study, overflow behaviors through a partially open tainter gate mounted on a standard ogee spillway were investigated by using the FLOW-3D. The results indicated that the discharge coefficient is in the range of 0.685 to 0.723. A relation of gate-controlled discharge to free discharge was proposed and a reasonable correlation between the free and controlled discharge was obtained. Pressures on the spillway crest and the gate were also investigated. As the gate opening rate decreases with a fixed gate opening height and the gate opening height increases at a fixed gate opening rate, negative pressures on the spillway crest and the dimensionless maximum pressures on the gate increase.

Estimation for Changing of Hydraulic States Caused by Gate Expansion in Asan Bay (아산만 배수갑문 확장사업에 따른 아산만 해역의 수리특성 변화 검토)

  • Park, Byong-Jun;Song, Hyun-Ku;Song, Tae-Kwan;Jang, Eun-Chul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.337-340
    • /
    • 2008
  • The gate expansion was planed to increase discharge capacity of gate structure at sea dike in Asan Bay. So it was estimated for changing of hydraulic states in Pyeongteak Harbor Zone caused by gate expansion, by 2D and 3D CFD Module. In result, influence of gate expansion was less than tidal current and discharge ratio between old gate and new gate was 4:6.

  • PDF