• Title/Summary/Keyword: dilute gas

Search Result 50, Processing Time 0.026 seconds

Analysis of Volatile Components of Sancho(Zanthoxylum schinifolium)by Solid Phase Micro Extraction (Solid Phase Micro Extraction을 이용한 산초의 휘발성 성분 분석)

  • 장희진
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.2
    • /
    • pp.119-123
    • /
    • 1999
  • Test of the optimum condition of solid phase micro extraction(SPME) was performed by use of 5 vol-atile components in dilute aqueous solution. Volatile components of Sancho(Zanthoxylum schinifolium) were isolated by SPME method and were analyzed by GC/MSD and compared with volatile compone-nts isolated by simultaneous distillation extraction (SDE) method. Total 31 components were identified by comparing gas chromatography retention time and mass spectral data. The major compounds were limonene geranyl acetate $\beta$-phellandrene phellandral mycene linalool rose oxide caproic acid and caprylic acid SPME sampling procedure was found to be a good method for qualitative analysis of the volatile components.

  • PDF

Silicon thin film and p-n junction diode made by $CO_2$ laser-induced CVD method ($CO_2$ Laser-induced CVD법에 의한 Silicon박막 및 p-n 접합 Silicon제작)

  • Choi, H.K.;Jeong, K.;Kim, U.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.662-666
    • /
    • 1989
  • Pure mono Silane(Purity: 99.99%) was used as a thin film source and [$SiH_4$ + $H_2$ (5%)] + [$PH_3$ + $H_2$(0.05%)] mixed dilute gas was used for p-n junction diode. The substrate was P-type silicon wafer (p=$3{\Omega}$ cm) with the direction (100). The crystalline qualities of deposited thin film were investigated by the X-ray diffraction, RHEED and TED patterns and the voltampere characteristics of p-n junction diode was identified by I-V curve.

  • PDF

Hydrodynamic Characteristics of the Rectangular Type Circulating Fluidized Bed (4각 순환유동층의 수력학적 특성)

  • Hyun, Sang Yeol;Rhee, Kwan Seok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.4
    • /
    • pp.232-236
    • /
    • 1997
  • A rectangular type circulating fluidized bed (CFB) with an internal nozzle and two partition walls was proposed. In this modified CFB, an internal nozzle and two slanted partition walls were additionally set in the riser. This cold mode apparatus was made of acrylic resin; the riser was 1500mm high and $1000{\times}1000mm^2$ in the cross sectional area, the internal nozzle was 200mm high and 10mm in the inner diameter, and the partition wall was 7mm thick. Glass beads of $91{\mu}m$ in the mean diameter were employed as bed materials. In the cold mode by using the proposed CFB with an internal nozzle, it was possible to change the particle hold up by changing the gas flow ratio of the nozzle to the total(Qn/Qt). It was found that the inflection point which devided the bed structure between the dense and the dilute phase in the riser varied with Qn/Qt.

  • PDF

Determination of sulfur containing organic drugs by means of thin layer chromatography and flask combustion method (Thinlayer chromatography및 oxygen combustion flask method에 의한 유기유황약품의 분리정량)

  • 백남호;김박광
    • YAKHAK HOEJI
    • /
    • v.13 no.2_3
    • /
    • pp.84-87
    • /
    • 1969
  • Microanalysis of organic sulfur compounds by means of combining thin layer chromatography and oxygen combustion flask method was attempted. The following procedure was found to be very simple and to give accurate results. The mixture of sulfa drugs was separated with T.L.C., and it was burned in a flask filled with oxygen, and the gas formed was absorbed in a dilute solution of sodium hydroxide. The solution was neuralized with hydrochloric acid and heated in a water bath. The sulfate ion formed was then treated with barium chromate solution and its absorbancy at 370 m.mu. was measured.

  • PDF

Composite Oxidizing Agents Generation Using Electrolysis of Dilute Hydrochloric Acid (묽은 산 전기분해에 의한 복합 산화제 생성)

  • Kang, Shin-Young;Park, Jong-Hun;Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.329-333
    • /
    • 2016
  • Disinfection by electrolysis would be useful for small wastewater treatment plant, combined sewer overflow, ballast water, swimming pool, and fish farming, where the transport, storage, and the use of chlorine gas is limited. This study investigated the feasibility of the electrolysis of dilute hydrochloric acid (HCl) for disinfection. The effects of HCl concentration, voltage and reaction time on the generation of oxidizing agents, HOCl, $O_3$, and $H_2O_2$, were examined in a series of batch test. The highest current efficiency was 99.3% which was found at 2.2%, 3 V, and 5 min of HCl concentration, voltage, and reaction time, respectively. Continuous electrolysis at 2.2% HCl, 3 V, and 5 min of the hydraulic retention time showed 97.4% of the current efficiency. Addition of sodium chloride up to 20 g/L linearly increased the oxidizing agents production. 92.2% of total coliforms were removed by the contact with the electrolyzed water.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control (대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구)

  • Won, Yang-Soo;Jo, Wan-Keun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.482-488
    • /
    • 2015
  • Biological treatment is promising alternative to conventional air pollution control method. Bioreactors for air pollution control have found most of their success in the treatment of dilute and high flow waste air streams containing volatile organic compounds and odor. The studies of mass transfer in biotrickling filters for air pollution control were of importance in order to control and optimize the purification process. The objectives of this study were to develop the experimental methodologies to evaluate the mass transfer coefficients of gas/liquid(trickling liquid), gas/solid(biomass) and liquid/solid in three phase biotrickling filtration. Also, this study characterized the influence factors on mass transfer such as dynamic holdup volume, gas/liquid flow rate ratio, biomass weight in reactor and recirculation rate of trickling medium for each phase of biotrickling filter.

A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident (아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • Recently, waste gas incineration is increasing due to strong environmental regulatory system in Korea. These incinerating facilities are usually connected with the top of the storage tank through pipeline and incinerate off gas with the flame. Therefore, the flame originated from these facilities is likely to move back into pipeline and might cause an explosion of the storage tank. Accordingly, the purpose of this study is to suggest the preventive measures and the way to improve the safety of these incineration systems through the cause analysis of a major industrial accident occurred in a acrylic acid manufacturing process in Korea. As a result of the study, the preventive measures are suggested as follows. (1) Air or inert gas inflow facilities should be well designed to dilute flammable gases into air or inert gas sufficiently before the blower is restarted in order to prevent the explosion (2) It is needed for the detonation-type flame arresters to be installed on the top of the storage tanks. (3) In case of using the deflagration-type flame arresters, it is necessary to install a rupture disk before the arresters, or blow off the flame outside tanks by connecting the tank top and the incinerator with hood-type pipe. (4) TDR should be installed to be restarted automatically after the momentary power failure.

Quantitative analysis of silver in chlorinated polymer (Chlorine을 함유한 고분자 물질 중 Ag의 정량분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.376-380
    • /
    • 2005
  • Quantitative analysis of silver from the thermal decomposition of chlorinated polymer contained nano silver is described. The chlorine contained in the chlorinated polymer (e.g. PVC) is liberated as hydrochloric acid gas by heating and a lot of silver produces AgCl. $HNO_3$ and $NH_4OH$ were used for dissolving the Ag and the AgCl. The silver complex was formed by $NH_4OH$. Then the complex was decomposed to silver by heating at $500^{\circ}C$ and the Ag was dissolved by dilute $HNO_3$. Recovery of silver in PVC material was 99.0%.

Eigenfunctions for Liouville Operators, Classical Collision Operators, and Collision Bracket Integrals in Kinetic Theory Made Amenable to Computer Simulations

  • Eu, Byung-Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.779-789
    • /
    • 2012
  • In the kinetic theory of dense fluids the many-particle collision bracket integral is given in terms of a classical collision operator defined in the phase space. To find an algorithm to compute the collision bracket integrals, we revisit the eigenvalue problem of the Liouville operator and re-examine the method previously reported [Chem. Phys. 1977, 20, 93]. Then we apply the notion and concept of the eigenfunctions of the Liouville operator and knowledge acquired in the study of the eigenfunctions to cast collision bracket integrals into more convenient and suitable forms for numerical simulations. One of the alternative forms is given in the form of time correlation function. This form, on a further manipulation, assumes a form reminiscent of the Chapman- Enskog collision bracket integrals, but for dense gases and liquids as well as solids. In the dilute gas limit it would give rise precisely to the Chapman-Enskog collision bracket integrals for two-particle collision. The alternative forms obtained are more readily amenable to numerical simulation methods than the collision bracket integrals expressed in terms of a classical collision operator, which requires solution of classical Lippmann-Schwinger integral equations. This way, the aforementioned kinetic theory of dense fluids is made fully accessible by numerical computation/simulation methods, and the transport coefficients thereof are made computationally as accessible as those in the linear response theory.