• 제목/요약/키워드: digital calibration

검색결과 377건 처리시간 0.033초

Adaptive Digital Background Gain Mismatch Calibration for Multi-lane High-speed Serial Links

  • Lim, Hyun-Wook;Kong, Bai-Sun;Jun, Young-Hyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권1호
    • /
    • pp.96-100
    • /
    • 2015
  • Adaptive background gain calibration loop for multi-lane serial links is proposed. In order to detect and cancel gain mismatches between lanes, a single digital loop using a ${\sum}{\Delta}$ ADC is employed, which provides a real-time adaptation of gain variations and is shared among all lanes to reduce power and area. Evaluation result showed that gain mismatches between lanes were well calibrated and tracked, resulting in timing budget at $10^{-6}$ BER increased from 0.261 UI to 0.363 UI with stable loop convergence.

디지털 빔 형성을 위한 배열 안테나 오차 보정 (Antenna Array Calibration for Digital Beamforming)

  • 최희영;박형근;김영수
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.501-505
    • /
    • 2003
  • There are many antenna array errors. They will distort the array beam pattern and result in an increased sidelobe level. A calibration technique is proposed for correcting the antenna array errors such as mutual coupling and unequal feeder characteristics. These are modeled as a matrix representing the interaction between the radiating elements. The matrix is estimated from the measured array response vectors. The antenna array errors are corrected by modifying the beamforming weight vector. It is verified by the electromagnetic simulation and experiment that the proposed technique reduces the sidelobe level and increases the antenna gain.

  • PDF

디지털 빔 형성을 위한 배열 안테나 오차 보정 (Antenna Array Calibration for Digital Beamforming)

  • 최희영;박형근;김영수;방승찬
    • 한국전자파학회논문지
    • /
    • 제15권2호
    • /
    • pp.199-205
    • /
    • 2004
  • 배열 안테나는 많은 오차 요인을 포함하고 있는데 그로 인하여 빔 패턴의 부엽 레벨이 증가하고 안테나 이득이 감소하게 된다. 본 논문에서는 배열 안테나 오차 중 소자간 상호 커플링과 급전부의 불균일한 전달 함수 오차를 제거하는 알고리즘을 제시하였다. 이러한 오차들은 방사 소자간 상호 연동을 나타내는 행렬로 모델링하였고 이 행렬은 특정 각도들에서 측정한 배열 응답 벡터로부터 추정하였다. 배열 안테나 오차는 추정된 오차 보정 행렬을 이용하여 빔 가중치를 미리 왜곡함으로써 보정하였다. 전파 시뮬레이션과 실험을 통하여 제시된 보정 알고리즘이 부엽 레벨을 감소시키고 안테나 이득을 증가하는 것을 확인하였다.

근거리 사진측량을 위한 CCD 사진기 검정에 관한 연구 (A Study on the CCD Camera Calibration for Close-Range Photogrammetry)

  • 유복모;이석군;최송욱;김기홍
    • 대한공간정보학회지
    • /
    • 제5권1호
    • /
    • pp.159-165
    • /
    • 1997
  • CCD 사진기는 수치영상을 별도의 처리과정 없이 실시간으로 얻을 수 있기 때문에 그 효용성이 날로 증대되고 있다. 본 연구에서는 CCD 사진기의 검정을 위해서 직접선형변환식과 방사 및 편심 왜곡을 검정하기 위한 검정식을 결합한 모형식을 구성하고 3차원 실험모형을 이용해서 검정계수들을 구하였다. CCD 사진기에 의한 수치영상을 상관계수를 이용하여 정합하고 대상물의 3차원 위치를 구함으로써 근거리 사진측량에서의 CCD 사진기 활용 가능성을 확인하였다.

  • PDF

디지털 빔 형성을 위한 부배열 채널 보정 및 성능 분석 (Subarray Channel Calibration and Performance Analysis for Digital Beam-Forming)

  • 장성훈;안창수;김동환;김선주
    • 한국전자파학회논문지
    • /
    • 제25권2호
    • /
    • pp.235-244
    • /
    • 2014
  • 항공기 능동 위상 배열(AESA) 레이더에 적용할 수 있는 레이더 안테나 부배열 채널 구성 및 보정에 대한 내용을 기술하였다. 설계된 부배열 채널 구조의 성능시험을 위하여 디지털 빔 형성이 가능한 12개 부배열 채널을 갖는 AESA 레이더 시연기(demonstrator)를 설계하고 제작하였다. 제작한 부배열 채널에서는 채널 간 크기 및 위상 오차가 필수적으로 발생하게 된다. 본 논문에서는 부배열 채널 간 발생하는 오차를 보정하는 방법을 제안하였다. 오차 보정후 채널의 신호 레벨과 모노펄스 기울기를 측정하여 보정된 효과를 확인하였다. 채널 보정 후 부배열 채널로 형성된 디지털 모노펄스 채널을 검증하기 위하여 별도로 구성된 아날로그 모노펄스 채널과 성능을 비교하였다. AESA 레이더 시연기의 성능 확인을 위하여 지상에서 원전계(far field) 시험을 수행하였다. 표적 모의 장치를 이용하여 단일 표적을 생성하고, 동일한 파형 및 탐색 조건하에서 탐지 및 추적시험을 수행하였다. 설계된 12개 부배열 채널 신호로 구성한 디지털 모노펄스 채널의 표적 탐지 추적 성능이 기존 아날로그 모노펄스 채널의 성능과 유사함을 확인하였다. 또한, 부엽으로 입사하는 재머 신호에 대하여 부배열 채널에서 적응 빔 형성(adaptive beam-forming) 기능이 효과적으로 동작함을 확인하였다.

아날로그-디지털 전달함수 평균화기법 기반의 Cyclic ADC의 디지털 보정 기법 (Digital Calibration Technique for Cyclic ADC based on Digital-Domain Averaging of A/D Transfer Functions)

  • 엄지용
    • 전자공학회논문지
    • /
    • 제54권6호
    • /
    • pp.30-39
    • /
    • 2017
  • 본 논문은 디지털영역에서의 평균화 기법을 이용한 cyclic ADC의 디지털 보정기법을 제안한다. 제안하는 보정기법은 1.5비트 MDAC의 커패시터 부정합으로 인해 발생하는 ADC의 비선형성을 보정한다. 부정합을 지니는 커패시터로 이루어진 1.5비트 MDAC은 이상적인 1.5비트 MDAC의 레지듀 플롯(residue plot)에 대해 대칭적인 레지듀 플롯을 지닌다. 커패시터 부정합을 지니는 1.5비트 MDAC의 고유한 레지듀 플롯은 대칭적인 아날로그-디지털 전달함수로 반영된다. 이상적인 아날로그-디지털 전달함수에 대해 대칭적인 두 아날로그-디지털 전달함수를 평균화함으로써, 비선형성이 보정된 아날로그-디지털 전달함수를 얻을 수 있다. 해당 아날로그-디지털 전달함수 평균화의 구현을 위해, 본 논문의 12비트 cyclic ADC는 1.5비트 MDAC의 동작 모드를 2개로 정의한다. 해당 cyclic ADC는 MDAC을 첫 번째 동작모드로 동작시킴으로써, 비선형성을 지니는 12.5비트 출력 코드를 획득한다. 샘플링 된 동일한 입력 아날로그 전압에 대해, MDAC을 두 번째 동작모드로 동작시킴으로써, cyclic ADC는 비선형성을 지니는 또 다른 12.5비트 출력 코드를 획득한다. 각 MDAC의 동작모드에 의해 발생하는 아날로그-디지털 전달함수는 이상적인 아날로그-디지털 전달함수에 대해 대칭적이기 때문에, 앞서 획득한 두 개의 비선형성을 지니는 12.5비트를 평균화함으로써, 비선형성이 보정된 최종 12비트 출력 코드를 획득할 수 있다. 제안하는 디지털 보정기법과 12비트 cyclic ADC는 $0.18-{\mu}m$ CMOS 공정을 이용하여 full-custom 형식으로 구현되었다. 측정된 SNDR(ENOB)와 SFDR은 각각 65.3dB(10.6비트 ENOB)와 71.7dB이다. 측정된 INL과 DNL은 각각 -0.30/+0.33LSB와 -0.63/+0.56LSB이다.

A Low-Voltage High-Speed CMOS Inverter-Based Digital Differential Transmitter with Impedance Matching Control and Mismatch Calibration

  • Bae, Jun-Hyun;Park, Sang-Hune;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권1호
    • /
    • pp.14-21
    • /
    • 2009
  • A digital differential transmitter based on CMOS inverter worked up to 2.8 Gbps at the supply voltage of 1 V with a $0.18{\mu}m$ CMOS process. By calibrating the output impedance of the transmitter, the impedance matching between the transmitter output and the transmission line is achieved. The PVT variations of pre-driver are compensated by the calibration of the rising-edge delay and falling-edge delay of the pre-driver outputs. The chip fabricated with a $0.18{\mu}m$ CMOS process, which uses the standard supply voltage of 1.8 V, gives the highest data rate of 4Gbps at the supply voltage of 1.2 V. The proposed calibration schemes improve the eye opening with the voltage margin by 200% and the timing margin by 30%, at 2.8 Gbps and 1 V.

화소 전류 보상 기법을 이용한 볼로미터 형의 비냉각형 적외선 이미지 센서 (Bolometer-Type Uncooled Infrared Image Sensor Using Pixel Current Calibration Technique)

  • 김상환;최병수;이지민;오창우;신장규;박재현;이경일
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.349-353
    • /
    • 2016
  • Recently, research on bolometer-type uncooled infrared image sensor which is made for industrial applications has been increasing. In general, it is difficult to calibrate fixed pattern noise (FPN) of bolometer array. In this paper, average-current calibration algorithm is presented for reducing bolometer resistance offset. A resistor which is produced by standard CMOS process, on the average, has a deviation. We compensate for deviation of each resistor using average-current calibration algorithm. The proposed algorithm has been implemented by a chip which is consisted of a bolometer pixel array, average current generators, current-to-voltage converters (IVCs), a digital-to-analog converter (DAC), and analog-to-digital converters (ADCs). These bolometer-resistor array and readout circuit were designed and manufactured by $0.35{\mu}m$ standard CMOS process.

POST-LAUNCH RADIOMETRIC CALIBRATION OF KOMPSAT2 HIGH RESOLUTION IMAGE

  • Yoon, Jong-Suk;Lee, Kyu-Sung;Chi, Jun-Hwa;Lee, Dong-Han
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.402-405
    • /
    • 2006
  • Radiometric calibration of optical image data is necessary to convert raw digital number (DN) value of each pixel into a physically meaningful measurement (radiance). To extract rather quantitative information regarding biophysical characteristics of the earth surface materials, radiometric calibration is often essential procedure. A sensor detects the radiation of sunlight interacted atmospheric constituents. Therefore, the amount of the energy reaching at the sensor is quite different from the initial amount reflected from the surface. To achieve the target reflectance after atmospheric correct, an initial step is to convert DN value to at-sensor radiance. A linear model, the simplest radiometric model, is applied to averaged spectral radiance for this conversion. This study purposes to analyze the sensitivity of several factors affecting on radiance for carrying out absolute radiometric calibration of panchromatic images from KOMPSAT2 launched at July, 2006. MODTRAN is used to calculate radiance at sensor and reflectance of target is measured by a portable spectro-radiometer at the same time the satellite is passing the target for the radiometric calibration. As using different contents of materials composing of atmosphere, the differences of radiance are investigated. Because the spectral sensitivity of panchromatic images of KOMPSAT2 ranges from 500 to 900 nm, the materials causing scattering in visible range are mainly considered to analyze the sensitivity. According to the verified sensitivity, direct measurement can be recommenced for absolute radiometric calibration.

  • PDF