• Title/Summary/Keyword: differential structure sensor

Search Result 40, Processing Time 0.03 seconds

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

Fabrication of Single Capacitive type Differential pressure sensor for Differential Flow meter (차압식 유량계를 실장을 위한 Single Capacitive Type Differential 압력 센서 개발)

  • Shin, Kyu-Sik;Song, Sangwoo;Lee, Kyungil;Lee, Daesung;Jung, Jae Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • In this paper, we have developed a differential pressure flow sensor designed as a single capacitive type. And the sensor was fabricated using a MEMS process. Differential pressure flow sensors are the most commonly used sensors for industrial applications. The sensing diaphragm and bonding joint of the MEMS pressure sensor are easily broken at high pressure. In this paper, we proposed a structure in which the diaphragm of the sensor was not broken at a pressure exceeding the proof pressure, and the differential pressure sensor was designed and manufactured accordingly. The operating characteristics of the sensor were evaluated at a pressure three times higher than the sensor operating pressure (0-3 bar). The developed sensor was $3.0{\times}3.0mm$ and measured with a LCR meter (HP 4284a) at a pressure between 0 and 3 bar. It showed 3.67 pF at 0 bar and 5.13 pF at 3 bar. The sensor operating pressure (0-3 bar) developed a pressure sensor with hysteresis of 0.37%.

Development of a Stewart Platform-based 6-axis Force Sensor for Robot Fingers

  • Luo, Minghua;Shimizu, Etsuro;Feifei, Zhang;Ito, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1814-1819
    • /
    • 2005
  • This paper describes the development of a Stewart platform-based robot force sensor with distinctive structure of ball joints. The number of ball joints is only a half of the similar style sensors, so it is possible to reduce size and weight of the sensor. The structure of ball joint is described and discussed. Furthermore, we use strain gauges, but not liner voltage differential transformers, as sensing elements, in order to reduce size and weight of the sensor. It is also proposed that beams are replaced with pipes as sensing elements of the sensor. The ball joints and sensing elements with pipes can effectively reduce the error of the sensor. A geometric analysis model is also proposed. The external force and its moment can be measured with this model. Moreover, the performance of this sensor was tested. The test results conducted to evaluate the sensing capability of the sensor is reported and discussed.

  • PDF

MISFET type H2 sensor using pd-black catalytic metal gate for high performance (Pd-black 촉매금속 이용한 고성능 MISFET 형 수소센서)

  • Kang, Ki-Ho;Cho, Yong-Soo;Han, Sang-Do;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.90-96
    • /
    • 2006
  • We have fabricated the Pd-blck/NiCr gate MISFET-type $H_2$ sensor to detect the hydrogen in atmosphere. A differential pair-type structure was used to minimize the intrinsic voltage drift of the MISFET. The Pd-black film was deposited in the argon environment by thermal evaporation. In order to eliminate the blister formation in the surface of the hydrogen sensing gate metal, Pd-black/NiCr double metal layer was deposited on the gate insulator. The scanning electron microscopy and the auger electron spectroscopy was used to analyze their surface morphology and basic structure. The Pd-black/NiCr gate MISFET has been shown high sensitivity and stability more than Pd-planar/NiCr gate MISFET.

Development of a Pressure Measurement System with the Parallel Structure (병렬구조의 압력측정 시스템 개발)

  • Yun, Eui-Jung;Kim, Jwa-Yeon;Lee, Kang-Won;Lee, Seok-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.328-333
    • /
    • 2006
  • In this paper, we developed a pressure measurement apparatus with the parallel structure to improve the measurement efficiency of pressure sensors by reducing the measurement time of pressure. The developed system has two parallel positions for loading Silicon pressure sensor and has a dual valve structure. The semiconductor pressure sensors prepared by Copal Electronics were used to confirm the performance of the developed measurement system. Two stage differential amplifier circuit was employed to amplify the weak output signal and the amplified output signal was improved utilizing a low-pass filter. New apparatus shows the measurement time of pressure two times shorter than that of conventional one with the serial structure, while both structures show the similar linear output versus pressure characteristics.

Eddy Current Sensor Development for Offshore Pipeline NDT Inspection (해양파이프라인 비파괴검사를 위한 와전류 센서 개발)

  • Lee, Seul-Gi;Song, Sung-Jin
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.199-206
    • /
    • 2015
  • Regular high-strength carbon steel is currently the most commonly used pipe material for onshore and offshore pipelines. The corrosion of offshore pipelines is a major problem as they age. The collapse of these structures as a result of corrosion may have a heavy cost is lives and assets. Therefore, their monitoring and screening is a high priority for maintenance, which may ensure the integrity and safety of a structure. Monitoring risers and subsea pipelines effectively can be accomplished using eddy current inspection to detect the average remaining wall thickness of corroded low-alloy carbon steel pipelines through corrosion scaling, paint, coating, and concrete. A test specimen for simulating the offshore pipeline is prepared as a standard specimen for an analysis and experiment with differential bobbin eddy current sensors. Using encircling coils, the signals for the defect in the simulated specimen are analyzed and evaluated in experiments. Differential bobbin eddy current sensors can diagnose the defects in a specimen, and experiments have been carried out using the developed bobbin eddy current sensor. As a result, the most optimum coil parameters were selected for designing differential bobbin eddy current sensors.

Infrared Light Absorbance: a New Method for Temperature Compensation in Nondispersive Infrared CO2 Gas Sensor

  • Yi, Seung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.303-311
    • /
    • 2020
  • Nondispersive infrared CO2 gas sensor was developed after the simulation of optical cavity structure and assembling the optical components: IR source, concave reflectors, Fresnel lens, a hollow disk, and IR detectors. By placing a hollow disk in front of reference IR detector, the output voltages are almost constant value, near to 70.2 mV. The absorbance of IR light, Fa, shows the second order of polynomial according to ambient temperatures at 1,500 ppm. The differential output voltages and the absorbance of IR light give a higher accuracy in estimations of CO2 concentrations with less than ± 1.5 % errors. After implementing the parameters that are dependent upon the ambient temperatures in microcontroller unit (MCU), the measured CO2 concentrations show high accuracies (less than ± 1.0 %) from 281 K to 308 K and the time constant of developed sensor is about 58 sec at 301 K. Even though the estimation errors are relatively high at low concentration, the developed sensor is competitive to the commercial product with a high accuracy and the stability.

Development and Evaluation of Non-Hydrous Skin Analogue Liquid Crystal using Thermo-Sensitivity Smart Sensor

  • Yoo, Kwang-Ho;Hong, Jae-Hwa;Eun, So-Hee;Jeong, Tae-Hwa;Jeong, Kwan-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.367-374
    • /
    • 2014
  • In this study, skin permeation enhancement was confirmed by designing it to have a structure and composition similarity to the intercellular lipids that improve miscibility with skin by cross-linked lipids poloxamer. The cross-linked lipids poloxamer was synthesized and analyzed by 1H NMR that structure dose had conjugated pluronic with ceramide3. Active component is released by modification of liquid crystal structure because PPO part, large-scale molecule block of pluronic, has hydrophobic nature at skin temperature of $35^{\circ}C$. Conjugated pluronic with ceramide3 was synthesized using Pluronic F127 and p-NPC (4-nitrophenyl chloroformate) at room temperature yielded 89%. Pluronic(Ceramide 3-conjugated Pluronic) was synthesized by reaction of p-NP-Pluronic with Ceramide3 and DMAP. The yield was 51%. This cross-linked lipids poloxamer was blended and dissolved at isotropic state with skin surface lipids, phospholipid, ceramide, cholesterol and anhydrous additive solvent. Next step was preceded by ${\alpha}$-Transition at low temperature for making the structure of Meso-Phase Lamella, and non-hydrous skin analogue liquid crystal using thermo-sensitivity smart sensor, lamellar liquid crystal structure through aging time. For confirmation of conjugation thermo-sensitivity smart sensor and non-hydrous skin analogue liquid crystal, structural observation and stability test were performed using XRD(Xray Diffraction), DSC(Differential Scanning Calorimetry), PM (Polarized Microscope) And C-SEM (Cryo-Scanning Electron Microscope). Thermo-sensitivity observation by Franz cell revealed that synthesized smart sensor shown skin permeation effect over 75% than normal liquid crystal. Furthermore, normal non-hydrous skin analogue liquid crystal that not applied smart sensor shown similar results below $35^{\circ}C$ of skin temperature, but its effects has increased more than 30% above $35^{\circ}C$.

A Scientific Approach for Improving Sensitivity and Selectivity of Miniature, Solid-state, Potentiometric Carbon Monoxide Gas Sensors by Differential Electrode Equilibria Mechanism (전극평형전위차 가스 센싱 메커니즘을 적용한 일산화탄소 소형 전위차센서의 특성 향상에 관한 연구)

  • Park, Jun-Young;Kim, Ji-Hyun;Park, Ka-Young;Wachsman, Eric D.
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.1
    • /
    • pp.92-96
    • /
    • 2010
  • Based on the differential electrode equilibria approach, potentiometric YSZ sensors with semiconducting oxide electrodes for CO detection are developed. To improve the selectivity, sensitivity and response-time of the sensor, our strategy includes (a) selection of an oxide with a semiconducting response to CO, (b) addition of other semiconducting materials, (c) addition of a catalyst (Pd), (d) utilization of combined p- and n-type electrodes in one sensor configuration, and (e) optimization of operating temperatures. Excellent sensing performance is obtained by a novel device structure incorporating $La_2CuO_4$ electrodes on one side and $TiO_2$-based electrodes on opposite substrate faces with Pt contacts. The resulting response produces additive effects for the individual $La_2CuO_4$ and $TiO_2$-based electrodes voltages, thereby realizing an even higher CO sensitivity. The device also is highly selective to CO versus NO with minor sensitivity for NO concentration, compared to a notably large CO sensitivity.

An Optimal Algorithm for the Sensor Location Problem to Cover Sensor Networks

  • Kim Hee-Seon;Park Sung-Soo
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.17-24
    • /
    • 2006
  • We consider the sensor location problem (SLP) on a given sensor field. We present the sensor field as grid of points. There are several types of sensors which have different detection ranges and costs. If a sensor is placed in some point, the points inside of its detection range can be covered. The coverage ratio decreases with distance. The problem we consider in this thesis is called multiple-type differential coverage sensor location problem (MDSLP). MDSLP is more realistic than SLP. The coverage quantities of points are different with their distance form sensor location in MDSLP. The objective of MDSLP is to minimize total sensor costs while covering every sensor field. This problem is known as NP-hard. We propose a new integer programming formulation of the problem. In comparison with the previous models, the new model has a smaller number of constraints and variables. This problem has symmetric structure in its solutions. This group is used for pruning in the branch-and-bound tree. We solved this problem by branch-and-cut(B&C) approach. We tested our algorithm on about 60 instances with varying sizes.

  • PDF