• Title/Summary/Keyword: differential pressure

Search Result 752, Processing Time 0.037 seconds

Study on the Assessment of the Criteria on a Door Closer for the Optimum Design of the Access Door of a Smoke Control Zone (제연구역 출입문의 최적 설계를 위한 도어클로저의 기준 산정에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.66-71
    • /
    • 2013
  • The purpose of this study is to assess the criteria on a floor hinge and door closer for the optimum design of the access door of a smoke control room. The door opening force due to differential pressure is 60.75 N, 40.5 N, 32.91 N and 12.66 N when the differential pressure is 60 Pa, 40 Pa, 32.5 Pa and 12.5 Pa, respectively. The door opening force of the floor hinge and door closer to which the criteria of KS F 2806 are applied is 27.5 N, 40 N, 75 N, 100 N and 125 N for the Nos. 1, 2, 3, 4 and 5 class floor hinges and door closers, respectively. This study compared the differential pressure and opening force limits of floor hinges and door closers with the values specified in NFSC 501A and found that they exceeded the criteria specified in NFSC 501A. Therefore, it is necessary to reflect the differential pressure and smoke control wind speeds as well as the opening forces specified in NFSC 501A on the design of floor hinges and door closers. The installation conditions of floor hinges and door closers of access doors differ depending on the type and name of a smoke control damper. This study found that Nos. 1, 2 and 3 floor hinges and door closers could be installed for access doors with low differential pressure and that Nos. 1 and 2 floor hinges and door closers could be installed for access doors with normal differential pressure.

Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke (모터구동 게이트밸브의 열림행정시 차압 작용에 의한 부하율 연구)

  • Kim, Bum-Nyun;Hong, Sung-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.35-41
    • /
    • 2007
  • The rate of loading in motor operated valve(MOV) can be defined as a variation of correlation between the actuator torque and the thrust upon the variation of operating load. This paper contains the analysis of characteristic and the validity of loading rate in the opening stroke of gate type motor operated valve. Also, this paper describes the evaluation result of loading rate for 40 MOVs' opening stroke using newly derived methodology in this study. Author has found a result that loading rate of opening stroke gets a negative value when the differential pressure is higher than 150 psi and this value goes up depending on the amount of the differential pressure.

A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve (모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구)

  • Kim, Dae-Woong;Yoo, Seong-Yeon;Park, Sung-Keun;Lee, Do-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

A study on the hydraulic limited slip differential system by pressure generator (압력발생장치를 이용한 유압식 차동제한장치에 관한 연구)

  • Choi C.H.;Huh Y.;Kim H.I.;Seok C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.433-434
    • /
    • 2006
  • The limited slip differential(LSD) is a device which enables the driving force to be transmitted from one slipping wheel to another wheel in such case that the car is stuck in clay or snow. When the unwanted slipping occurs on one wheel, the LSD temporarily restraints the differential motion to transmit the driving force in the other wheel. So far, many types of LSD were developed such as mechanical lock type, disk clutch type, viscous coupling type, torsion type and multiple clutch type. we designed a new type of the hydraulic LSD which uses the principle of trochoid gear pump.

  • PDF

Effect of Igniter's Burning Rate on Negative Differential Pressure of Interior Ballistics (점화제 연소율이 강내탄도의 NDP에 미치는 영향)

  • Sung, Hyung-Gun;Jang, Jin-Sung;Yoo, Seung-Young;Oh, Seok-Hwan;Choi, Dong-Whan;Roh, Tae-Seong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.520-526
    • /
    • 2012
  • The appearance of the negative differential pressure(NDP), in which the shot base pressure is higher than the breech pressure, indicates that a potential damage on the gun system is increased. In order to safeguard the gun system, the igniter must be designed to minimize the NDP during the firing process. From this reason, the effect of igniter's burning rate on the NDP of the interior ballistics has been investigated through the numerical simulations. The NDP has been increased with increment of the coefficient in the burning rate of the igniter. A sudden change of the chamber pressure has been shown in case of using a singular coefficient.

  • PDF

The Intact Evaluation of High Pressure Control Valve Trim Parts (고차압 제어밸브 트림부 분석 및 개선방안 검토)

  • Jang, H.;Yoon, I.S.;Kim, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.581-584
    • /
    • 2008
  • At the inlet and outlet differential pressure and The fluid velocity over 32m/s are damaged (Plug, sheet ring, trim) About reduction trim parts of the control valve. AOV of the differential pressure 1,500psi become often the damage in the nuclear power plant. Damages of AOV studied CFD analysis and improvement program. Multi-stage trim designs which decrease a fluid kinetic energy are demanded and AOV parts are demanded case hardening and material change.

  • PDF

Hydrodynamic Behavior Analysis of Vertical-Cylindrical Liquid-Storge Tanks by Mathematically Analytic Method (수학적 해석 방법에 의한 액체저장탱크의 액동압 거동 해석)

  • Park, Jong-Ryul;Oh, Taek-Yul
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.628-635
    • /
    • 2001
  • Hydrodynamic behavior and response of vertical-cylindrical liquid-storage tank is considered. The equation of the liquid motion is shown by Laplace's differential equation with the fluid velocity potential. The solution of the Laplace's differential equation of the liquid motion is expressed with the modified Bessel functions. Only rigid tank is studied. The effective masses and heights for the tank contents are presented for engineering design model.

  • PDF

Power Generation and Control System Using Differential Pressure of District Heating Pipeline in a Substation (지역난방 사용자기계실 내 열수송관 차압을 이용한 발전 및 제어 기술)

  • Kim, Kyung Min;Park, Sung Yong;Oh, Mun Sei
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.90-96
    • /
    • 2017
  • When the hot water is supplied through the district heating (DH) pipeline, a pressure differential control valve (PDCV) protects the DH user equipment from the high pressure DH water and helps to supply DH water to long distance. It also controls the temperature and adjust the pressure in the main district heating pipeline. However, cavitation occurs in PDCV due to the use of high pressure DH water. It causes frequent failures and many problems. It also causes energy loss and complaints to both operators and users. In order to solve these problems, we will introduce the energy saving technology to replace the primary side PDCV with hydraulic turbine, convert the differential pressure into electricity, and utilize electricity as the power of the secondary side pump.

Study on the Propellant Position for the Decrease of the Differential Pressure in the Interior Ballistics of a Gun Propulsion System (강내탄도 내 차압 감소를 위한 추진제 위치 연구)

  • Jang, Jin-Sung;Sung, Hyung-Gun;Roh, Tae-Seong;Choi, Dong-Whan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.72-78
    • /
    • 2012
  • The position effect of the solid propellant in the combustion chamber on the decrease of the differential pressure has been investigated using the IBcode. Generally the metallic cartridge or CCC (combustible cartridge case) are used to load the propellant of the gun propulsion system. The position of the cartridge(propellant) is, therefore, a major factor for the interior ballistics in case the combustion chamber is larger than the cartridge. In this study, three different positions in the empty space of the chamber have been considered. As results, the case of the propellant located in the region near the base and breech has shown that the negative differential pressure and the difference between the breech pressure and the base pressure are much higher than those of the case of the propellant located in the center of the chamber. The case of the propellant in the center of the chamber is, therefore, more profitable to improve the performance of the interior ballistics.

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF