• Title/Summary/Keyword: diesel generator

Search Result 315, Processing Time 0.026 seconds

Torsional Vibration Analysis in Large Two-Stroke Diesel Engines for Stationary Power Plants. (발전용 대형 2행정 디젤 엔진의 비틈진동 해석)

  • Park, Jong-Po;Park, Hui-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2529-2534
    • /
    • 2000
  • Torsional vibration analysis in a large two -stroke low speed diesel engine and generator system for stationary power plants is performed to verify that the vibration characteristics of shafting system meet design requirements. Our own developed S/W is employed for the analysis, whose results are evaluated comparing with measurements. Vibration analysis results of the system are presented according to the change of loading(unload, 100%load, 110% load) and operating(mis-firing, uneven firing) conditions of the stationary power plants.

Study on Remote Monitoring System for manned island electrification in Korea (하화도 태양광발전시스템의 원격측정 시스템 연구)

  • Lee, Man-Geun;Jung, Myung-Woong;Kim, Bu-Ho
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.7-14
    • /
    • 1996
  • Korean goverment is promoting "the Rural Electrification Project" to replace the diesel generators with PV power supply. The PV-diesel hybrid system are proven more cost effective than that of the existing, especially in the. case of small islands(less than 70 households). In this paper, we intend to introduce the Hahwado island PV system assisted with diesel generator and remote monitoring systems as observator. The purpose of this observator is to have minimum maintenance, to improve economical effciency and system reliability by checking the system periodically at certain time interval, and to make diagnosis of its operating situations. The remote monitoring system was designed to communicate between the central and local site through exclusive telephone line on real-time base, using Window '95 version.

  • PDF

A STUDY ON THE SPEED CONTROL OF A LOW SPEED-LONG STROKE MARINE DIESEL ENGINE (저속 장행정 박용디젤기관의 속도제어에 관한 연구)

  • 유영호;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.53-61
    • /
    • 1988
  • Speed of a diesel engine is usually controlled by the hydraulic governor which uses the centrifugal force of rotating fly balls for sensing the error speed. But for a recently developed high efficient, low speed and long stroke 2 cycle marine diesel engine, this governor doesn't work well enough because of too much changes of toraring force during one revolution of engine and too long uncontrollable time due to small numbers of cylinder. For improvement of jiggling phenomena and unstability various studies are being carried out, but they are not enough for a steep load change in a small ship's generator plant or at rough sea condition in a propulsion engine. In this paper, authors propose a new method to control a fuel before the change of angular velocity due to load change by feedforward the change of load, and find that the proposed method shows quite a good control performance in comparision to the customary PID control method by simulation using a digital computer for the various load change.

  • PDF

MODELING AND PI CONTROL OF DIESEL APU FOR SERIES HYBRID ELECTRIC VEHICLES

  • HE B.;OUYANG M.;LU L.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.91-99
    • /
    • 2006
  • The diesel Auxiliary Power Unit (APU) for vehicle applications is a complex nonlinear system. For the purpose of this paper presents a dynamic average model of the whole system in an entirely physical way, which accounts for the non-ideal behavior of the diode rectifier, the nonlinear phenomena of generator-rectifier set in an elegant way, and also the dynamics of the dc load and diesel engine. Simulation results show the accuracy of the model. Based on the average model, a simple PI control scheme is proposed for the multivariable system, which includes the steps of model linearization, separate PI controller design with robust tuning rules, stability verification of the overall system by considering it as an uncertain one. Finally it is tested on a detailed switching model and good performances are shown for both set-point following and disturbance rejection.

Operation Algorithm of Hybrid Power System for Power Supply in a Remote Island (낙도 전력공급을 위한 복합발전시스템의 운전제어 알고리즘)

  • Kim, E.S.;Kim, S.K.;Lee, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.293-295
    • /
    • 2001
  • In this paper, a control algorithm of a stand-alone type photovoltaic/wind/diesel hybrid power system for operation in a remote island, is proposed in detail. Power controllers are used to combine two different power outputs of photovoltaic and wind-power generations into DC output, which is converted into AC power to meet load while charging the storage battery for later use. In the event that the whole power load cannot be met by photovoltaic and wind power only, power stored in the battery cell is supplied and if even this power run out, diesel generator will be applied. Certain portion of diesel power is used to cover the load and the other to charge the battery.

  • PDF

Assessment of the Influence on Harmonic Torque in Diesel Generating System by using EMTP (EMTP를 이용한 디젤발전시스템 Harmonic Torque의 계통영향 평가)

  • Kim, Soo-Nam;Jung, Moon-Goo;Baek, Byung-San;Kim, Ik-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.125-127
    • /
    • 2003
  • This paper presents method of the assessment on the Influence of harmonic torque in diesel generating system by using EMTP(Electromagnetic Transient Program). The objectives is to analysis the influence on power oscillation and voltage fluctuation due to the periodically varying torque developed by the new diesel generator to be installed in existing power system.

  • PDF

Investigation on Replacement Criteria for Aged Diesel Driven Power Generation Facility by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 노후 디젤발전설비 교체기준 고찰)

  • Park, Myungsoo;Song, Gee Wook;Seo, Sang Il;Won, Dong Ju
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • The diesel driven power generation facility provides most of electricity of island region where is isolated from the main land power supply system. It is possible to extend the life of diesel driven power generation facility by periodic maintenance. However, the long-term use of diesel driven power generation facility increases the operating cost due to aging hardware and reduced plant efficiency. In other words, on-time replacement of aging diesel driven power generation facility reduces plant operation cost. The purpose of this study presents major indicators to represent the characteristics of the diesel generator and conducts sensitivity analysis using Monte Carlo analysis. In addition, status core which indicates quantitatively the state of the diesel driven power generation facility is defined and prepare the replacement criteria based on the state score.