Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Diagnostic Significance of Radionuclide Venography - A Comparison with X-ray Contrast Venography - (방사성동위원소정맥촬영술(放射性同位元素靜脈撮影術)의 진단적(診斷的) 의의(意義) - X-선정맥조영술(線靜脈造影術)과의 비교(比較) 연구(硏究) -)

  • Bae, S.H.;Park, J.H.;Han, M.C.;Cho, B.Y.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.19-25
    • /
    • 1981
  • Radionuclide venographies were performed in 138 limbs of 58 patients and X-ray contrast venographies were performed in 23 paitents of them. Positive radionuclide venography findings were area of decreased sponding to the region of thrombosis, abnormal collateral flows below the lesion. The success rate of radionulide venography was 89% and the overall concordance between radionuclide venography and X-ray contrast venography was 91%. Radionuclide venography is simple and easy to perform and less invasive than X-ray contrast venography. These results indicate that radionuclide venography is the most ideal screening test for the detection of venous thrombosis in patient with signs & symptoms of deep vein thrombosis.

  • PDF

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

A Study on the Architectural Planning of the X-ray Unit in General Hospital (종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Application of X-ray Computer Tomography (CT) in Cattle Production

  • Hollo, G.;Szucs, E.;Tozser, J.;Hollo, I.;Repa, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.12
    • /
    • pp.1901-1908
    • /
    • 2007
  • The aim of this series of experiments was to examine the opportunity for application of X-ray computer tomography (CT) in cattle production. Firstly, tissue composition of M. longissimus dorsi (LD) cuts between the $11-13^{th}$ ribs (in Exp 1. between the $9-11^{th}$ ribs), was determined by CT and correlated with tissue composition of intact half carcasses prior to dissection and tissue separation. Altogether, 207 animals of different breeds and genders were used in the study. In Exp. 2 and 3, samples were taken from LD cuts, dissected and chemical composition of muscle homogenates was analysed by conventional procedures. Correlation coefficients were calculated among slaughter records, tissues in whole carcasses and tissue composition of rib samples. Results indicated that tissue composition of rib samples determined by CT closely correlated with tissue composition results by dissection of whole carcasses. The findings revealed that figures obtained by CT correlate well with the dissection results of entire carcasses (meat, bone, fat). Close three-way coefficients of correlation (r = 0.80-0.97) were calculated among rib eye area, volume of cut, pixel-sum of adipose tissue determined by CT and intramuscular fat or adipose tissue in entire carcasses. Estimation of tissue composition of carcasses using equations including only CT-data as independent variables proved to be less reliable in prediction of lean meat and bone in carcass ($R^2 = 0.51-0.86$) than for fat (($R^2 = 0.83-0.89$). However, when cold half carcass weight was also included in the equation, the coefficient of determination exceeded $R^2 = 0.90$. In Exp. 3 tissue composition of rib samples by CT were compared to the results of EUROP carcass classification. Findings revealed that CT analysis has higher predictive value in estimation of actual tissue composition of cattle carcasses than EUROP carcass classification.

Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea (국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석)

  • Kang, Kyoung-Mook;Suh, Tae-Young;Kim, Yong-Sang;Yun, Seon-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2020
  • The various types of radiation-generator devices have been used in animal hospitals, and the safety for radiation workers is becoming important in Korea. This study investigated and analyzed the radiation safety management for diagnostic radiation-generator devices and radiation workers of animal hospital. The number of radiation-generator devices and radiation workers of animal hospital increased from 2,138 to 2,972 and from 2,644 and 5,733 for six years. The number of general X-ray, CT, C-arm, portable and dental X-ray in 2019 were 2,204, 58, 67, 770, and 14. The number of veterinarian, veterinary nurse, veterinary assistant, and others in 2019 were 4,236, 1,080, 404, and 13. The average exposure dose of radiation workers in 2018 were 0.21mSv in surface dose, 0.18mSv in depth doses. This study is expected to be the basic data for the safety management of radiation-generating devices and radiation workers in animal hospital.

전파정류 방식을 사용한 의료용 X선 장치의 성능평가

  • Kim, Yeong-Pyo;Kim, Tae-Gon;Lee, Ho-Sik;Cheon, Min-U;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.248-248
    • /
    • 2009
  • Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. But, X-ray radiation could be exposed to patient and it is very harmful to the patient. In order to reduce being bombed, the many research and development is now advanced. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

Non Dosimetry Measurements Use for Patients Safety : NDD-M (환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M)

  • Gil, Jong-Won;Seon, Jong-Ryoul;Song, Wol-Su
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type (37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치)

  • 김학성;유동욱;임근희;완충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.