• Title/Summary/Keyword: device control

Search Result 5,526, Processing Time 0.036 seconds

The Trend Analysis of Propulsion System for Railway Vehicle Using Patent Analysis (특허분석을 통한 철도차량용 추진제어장치 기술 분석)

  • Han, Young-Jae;Lee, Su-Gil;Park, Chan-Kyoung;Kim, Young-Guk;Bae, Chang-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.131-138
    • /
    • 2018
  • In this study, we investigated the trend of technological development in major countries related to the propulsion equipment of railway vehicles. The propulsion system is the main equipment of electric vehicles. A lot of time and investment are required in order to ensure the development of technology. Therefore, developed countries have maximized their effort to develop technologies with safety, reliability, and convenience of maintenance. They have also done their utmost to prevent technology transfer to other countries after the development of new technologies. For example, Toshiba of Japan developed a new 3,300V/1,500 A class IGBT power device, but was reluctant to export it to foreign countries in order to protect this technology. In this study, we analyzed the patents applied for related to propulsion control systems and presented the direction of development during the technical development of these systems. The patent analysis of the core technologies was conducted using the Thomson Innovation DB. We examined the number of patents applied for by country, year and major applicant. As a result of the analysis, it was found that the proportion of patent applications per country was in the order of China, 48%, Europe 16.6%, and the United States 14.9%. The patent situation of the top 10 principal applicants revealed that (the top three were?) ABB 14%, GE 13%, and CRRC 12%. At the same time, we also conducted a qualitative analysis of the level of technical development by evaluating such factors as the influence index, quotation, market securing power and citation. Based on the result of the patent analysis, we presented the direction of technical development of the propulsion control equipment of railway vehicles. Based on the analysis results, it was found that domestic applicants considerably reduced their efforts to protect their patents from foreign companies. Nowadays, most of the electric motors used in Korea are induction motors. In advanced countries, permanent magnet electric motors are employed in new railway lines. Therefore, intensive investment is needed in new developments.

Effect of machining precision of single ceramic restorations on the marginal and internal fit (단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향)

  • Son, Keunbada;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks and to evaluate the correlation. Materials and methods: Single restorations were designed using a CAD software program. The crown designed model file was extracted from the CAD software program. Three types of lithium disilicate blocks (Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA) were milled using a milling machine. For the fabrication of the crown scanned model file, the intaglio surface of the restoration was digitized using a contact scanner. Then, using the three-dimensional inspection software (Geomagic control X; 3D Systems), the process of the overlap of the crown designed model and the scanned model and 3-dimensional analysis was conducted. In addition, the marginal and internal fit of the crowns was evaluated by a silicone replication method. The difference among three types of single ceramic crown was analyzed using a Kruskal-Wallis H test, and Spearman correlation analysis was performed to analyze the correlation between machining precision and fitness (α=.05). Results: There was a significant difference in the machining precision and the marginal and internal fit according to the type of ceramic block (P<.001). In addition, the machining precision and the marginal and internal fit were positively correlated (P<.001). Conclusion: The marginal fit of crowns fabricated according to the types of ceramic blocks was within the clinically acceptable range (< 120 ㎛), so it can be regarded as appropriate machining precision applicable to all clinical as aspects in terms of the marginal fit.

A 12b 200KHz 0.52mA $0.47mm^2$ Algorithmic A/D Converter for MEMS Applications (마이크로 전자 기계 시스템 응용을 위한 12비트 200KHz 0.52mA $0.47mm^2$ 알고리즈믹 A/D 변환기)

  • Kim, Young-Ju;Chae, Hee-Sung;Koo, Yong-Seo;Lim, Shin-Il;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.48-57
    • /
    • 2006
  • This work describes a 12b 200KHz 0.52mA $0.47mm^2$ algorithmic ADC for sensor applications such as motor controls, 3-phase power controls, and CMOS image sensors simultaneously requiring ultra-low power and small size. The proposed ADC is based on the conventional algorithmic architecture with recycling techniques to optimize sampling rate, resolution, chip area, and power consumption. The input SHA with eight input channels for high integration employs a folded-cascode architecture to achieve a required DC gain and a sufficient phase margin. A signal insensitive 3-D fully symmetrical layout with critical signal lines shielded reduces the capacitor and device mismatch of the MDAC. The improved switched bias power-reduction techniques reduce the power consumption of analog amplifiers. Current and voltage references are integrated on the chip with optional off-chip voltage references for low glitch noise. The employed down-sampling clock signal selects the sampling rate of 200KS/s or 10KS/s with a reduced power depending on applications. The prototype ADC in a 0.18um n-well 1P6M CMOS technology demonstrates the measured DNL and INL within 0.76LSB and 2.47LSB. The ADC shows a maximum SNDR and SFDR of 55dB and 70dB at all sampling frequencies up to 200KS/s, respectively. The active die area is $0.47mm^2$ and the chip consumes 0.94mW at 200KS/s and 0.63mW at 10KS/s at a 1.8V supply.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

HISTOLOGICAL CHANGES IN THE ELONGATED BONE AFFECTED BY OSTEODISTRACTION OF THE MANDIBLE IN THE DOG (성견 하악골 절단 후 기계적 골 견인에 의해 형성된 골 신장부에 대한 시기별 조직학적 변화)

  • Baek, Sun-Ho;Ahn, Byoung-Keun;Park, Young-Ju;Park, Hee-Geon;Park, Jun-Woo;Rhee, Gun-Joo;Lee, Yong-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.404-416
    • /
    • 2001
  • Purpose : Traditionally, the treatement of choice has been a bone grafting procedure to increase the length of bone in case of actual length discrepancy. But, bone grafting procedure has many disadvantages, for example, graft resorption, donor site morbidity, and so on. So, many trials have been performed to avert the use of autogenous bone graft via introducing new materials or methods. And, one of those trials has been realized by the development of a technique inducing bone lengthening by osteotomy (or corticotomy) and slow gradual distraction of the osteotomized segments. This new technique of bone lengthening dates back to the early 20th century. But, the majority of information concerning the biology of new bone formation during bone lengthening and technical details of the procedure were produced by extensive clinical and experimental studies performed by Ilizarov, a Russian surgeon. According to Ilizarov, with adequate blood supply, preservation of periosteum, rigid fixation of the osteotomized segments, and proper rate and rhythm of distraction, intramembranous bone rapidly develops within the distraction gap in the limb lengthening procedure. In the limb lengthening, many orthopedic surgeons try to observe the biologic and clinical principles recommended by Ilizarov. In the oral and maxillofacial region, however, not a few studies must be performed to apply this surgical technique in the clinical cases. Besides, the mechanism of bone formation in the distraction gap is not clear, yet. The purpose of this experiment was to scrutinize serially the histological changes in the elongated bone affected by osteodistraction of the mandibular body in an adult canine model. In addition, it was performed to confirm the presence of specific region(s) which was important in the bone formation in the gap through the observation of the expression pattern of osteocalcin and osteonectin with the immunohistochemical examination. Materials and Methods : The experimental and control specimens were obtained from seven adult male mongrel dogs weighing over 20kg. The distractors were custom-made linear extraoral devices and bicortical fixation screws were 2.3mm in diameter, 50mm in total length, 15mm in screw length. The distractors were devised to produce a linear gap of 0.75mm between two bony segments every $360^{\circ}$ turn of the rotation rod of the device. The mandibular body of the right side of each animal was corticotomized perpendicular to the occlusal plane and then two bony segments were separated completely by careful manipulation of the segments with bone forceps. The left side of each animal was left intact. This side was served as control. At sixth day after osteotomy and fixation of the segments were performed, distraction of the segments was commenced with a rate of 1.1mm/day and a rhythm of two/day for ensuing 7 days. The animals were euthanized at the 16th. 29th, and 44th day after the osteotomy. The bony specimens were decalcified, embedded in paraffin, sectioned $5{\mu}m$ thick and stained with H&E. The prepared specimens were examined under the light microscope. And, immunohistochemical examinations using anti-osteocalcin antibody (OC1, Biodesign, USA) and anti-osteonectin antibody (Haematologic Technologies Inc., Essex, VT) to locate the expressions of osteocalcin and osteonectin, respectively, were performed. Results : 1. New bone was observed already at the 16th. day after osteotomy. This suggests that new bone formation in osteodistraction was commenced at an early stage of the regenerative process. But, radiologically and microscopically, bony union was not completed in the distraction gap at the 44th. day after osteotomy. Therefore, rigid fixation must be maintained between the bony fragments till the complete bony union is confirmed clinically rather than one month or so after the completion of distraction.

  • PDF

A Study on Intuitive IoT Interface System using 3D Depth Camera (3D 깊이 카메라를 활용한 직관적인 사물인터넷 인터페이스 시스템에 관한 연구)

  • Park, Jongsub;Hong, June Seok;Kim, Wooju
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.2
    • /
    • pp.137-152
    • /
    • 2017
  • The decline in the price of IT devices and the development of the Internet have created a new field called Internet of Things (IoT). IoT, which creates new services by connecting all the objects that are in everyday life to the Internet, is pioneering new forms of business that have not been seen before in combination with Big Data. The prospect of IoT can be said to be unlimited in its utilization. In addition, studies of standardization organizations for smooth connection of these IoT devices are also active. However, there is a part of this study that we overlook. In order to control IoT equipment or acquire information, it is necessary to separately develop interworking issues (IP address, Wi-Fi, Bluetooth, NFC, etc.) and related application software or apps. In order to solve these problems, existing research methods have been conducted on augmented reality using GPS or markers. However, there is a disadvantage in that a separate marker is required and the marker is recognized only in the vicinity. In addition, in the case of a study using a GPS address using a 2D-based camera, it was difficult to implement an active interface because the distance to the target device could not be recognized. In this study, we use 3D Depth recognition camera to be installed on smartphone and calculate the space coordinates automatically by linking the distance measurement and the sensor information of the mobile phone without a separate marker. Coordination inquiry finds equipment of IoT and enables information acquisition and control of corresponding IoT equipment. Therefore, from the user's point of view, it is possible to reduce the burden on the problem of interworking of the IoT equipment and the installation of the app. Furthermore, if this technology is used in the field of public services and smart glasses, it will reduce duplication of investment in software development and increase in public services.

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Effect of the Flavonoid Luteolin for Dextran Sodium Sulfate-induced Colitis in NF-${\kappa}B^{EGFP}$ Transgenic Mice (Dextran Sodium Sulfate 유발 장염 모델에서 루테올린의 치료효과)

  • Jang, Byung-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.26-35
    • /
    • 2006
  • Background: Luteolin, a flavone found in various Chinese herbal medicines is known to possess anti-inflammatory properties through its ability to inhibit various proinflammatory signaling pathways including NF-${\kappa}B$ and p38 MAPK. In this study, we investigated the potential therapeutic effect of luteolin on dextran sodium sulfate (DSS)-induced colitis. Materials and Methods: We used a transgenic mouse model expressing the enhanced green fluorescent protein (EGFP) under the transcriptional control of NF-${\kappa}B$ $cis$-elements. C57BL/6 NF-${\kappa}B^{EGFP}$ mice received 2.5% DSS in their drinking water for six days in combination with daily luteolin administration (1mg/kg body weight, 0.1ml vol, intragastric) or vehicle. NF-${\kappa}B$ activity was assessed macroscopically with a Charge-Coupled Device (CCD) camera and microscopically by confocal analysis. Results: A significant increase in the Disease Activity Index (DAI), histological score (p<0.05), IL-12 p40 secretion in colonic stripe culture (p<0.05) and EGFP expression was observed in luteolin and/or DSS-treated mice compared to water-treated mice. Interestingly, a trend toward a worse colitis (DAI, IL-12p40) was observed in luteolin-treated mice compared to non-treated DSS-exposed mice. In addition, EGFP expression (NF-${\kappa}B$ activity) strongly increased in the luteolin-treated mice compared to control mice. Confocal microscopy showed that EGFP positive cells were primarily lamina propria immune cells. Conclusions: These results suggest that luteolin is not a therapeutic alternative for intestinal inflammatory disorders derived for primary defects in barrier function. Thus, therapeutic intervention targeting these signaling pathways should be viewed with caution.

  • PDF

Effect of Physical Control Technology on Aspergillus ochraceus Reduction (물리적 제어기술이 Aspergillus ochraceus 저감화에 미치는 영향)

  • Lee, Eun-Seon;Kim, Jong-Hui;Kim, Bu-Min;Oh, Mi-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.5
    • /
    • pp.447-453
    • /
    • 2021
  • In this study, the effectiveness of physical control technology, a combined light sterilization (LED, UV) and hot water treatment in reducing Aspergillus ochraceus for food production environment was investigated. In brief, 1 mL aliquot of A. ochraceus spore suspension (107-8 spore/mL) was inoculated onto stainless steel chips, which was then dried at 37℃, and each was subjected to different physical treatment. Treatments were performed for 0.5, 1, 2, 5, 8, and 11 hours to reduce the strains using a light-emitting diode, but no significant difference was confirmed among the treatments. However, a significant reduction was observed on the chips treated with UV-C exposure and hot water immersion. After being treated solely with 360 kJ/m2 of UV-C on stainless steel chip, the fungi were significantly reduced to 1.27 log CFU/cm2. Concerning the hot water treatment, the initial inoculum amount of 6.49 log CFU/cm2 was entirely killed by immersion in 83℃ water for 5 minutes. Maintaining a high temperature for 5 minutes at the site is difficult. Thus, considering economic feasibility and usability, we attempted to confirm the appropriate A. ochraceus reduction conditions by combining a relatively low temperature of 60℃ and UV rays. With the combined treatments, even in lukewarm water, A. ochraceus decreased significantly through the increases in the immersion time and the amount of UV-C irradiation, and the yield was below the detection limit. Based on these results, if work tools are immersed in 60℃ lukewarm water for 3 minutes and then placed in a UV sterilization device for more than 10 minutes, the possibility of A. ochraceus cross-contamination during work is expected to be reduced.