• Title/Summary/Keyword: depth dose

Search Result 510, Processing Time 0.026 seconds

Dosimetric Characteristics of 6 MV Modified Beams by Physical Wedges of a Siemens Linear Accelerator

  • Zabihzadeh, Mansour;Birgani, Mohammad Javad Tahmasebi;Hoseini-Ghahfarokhi, Mojtaba;Arvandi, Sholeh;Hoseini, Seyed Mohammad;Fadaei, Mahbube
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1685-1689
    • /
    • 2016
  • Physical wedges still can be used as missing tissue compensators or filters to alter the shape of isodose curves in a target volume to reach an optimal radiotherapy plan without creating a hotspot. The aim of this study was to investigate the dosimetric properties of physical wedges filters such as off-axis photon fluence, photon spectrum, output factor and half value layer. The photon beam quality of a 6 MV Primus Siemens modified by 150 and 450 physical wedges was studied with BEAMnrc Monte Carlo (MC) code. The calculated present depth dose and dose profile curves for open and wedged photon beam were in good agreement with the measurements. Increase of wedge angle increased the beam hardening and this effect was more pronounced at the heal region. Using such an accurate MC model to determine of wedge factors and implementation of it as a calculation algorithm in the future treatment planning systems is recommended.

A study on the photoreflectance of B ion implanted GaAs (B 이온을 주입시킨 GaAs의 Photoreflectance에 관한 연구)

  • 최현태;배인호
    • Electrical & Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.372-378
    • /
    • 1996
  • The phtoreflectance(PR) spectra of B ion implanted semi-insulating(SI) GaAs were studied. Ion implantation was performed by 150keV implantation energy and 1*10/aup 12/-10$^{15}$ ions/c $m^{2}$ doses. Electronic band structure was damaged by ion implantation with above 1*10$^{13}$ ions/c $m^{2}$ dose. When samples were annealed, " peak was observed at 30-40meV below band gap( $E_{g}$). It should be noted that this energy is close to the ionization energies of S $i_{As}$ , and GeAs in G $a_{As}$ which are also found as impurities in LEC GaAs, it is therefore possible that this feature is related to S $i_{As}$ , or G $e_{As}$ and B ions by implanted defect associated with them. From PR spectra of etched samples which is as-implanted by 1*10$^{14}$ and 1*10$^{15}$ ions/c $m^{2}$ dose, the depth of destroyed electronic band structure was from surface to 0.2.mu.m below surface.nic band structure was from surface to 0.2.mu.m below surface.

  • PDF

Radiotherapy Treatment Planning using Computed Tomography in Breast Cancer (유방암에서 CT planning를 이용한 치료계획)

  • 김성규;신세원;김명세
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.59-65
    • /
    • 1992
  • Carcimoma of the breast are first frequency malignancy in women in the world. third frequency in Korea. Radiation therapy in breast cancer were treated through opposed tangential fields with photon beam or electron beam. Density within the field and thickness to tumor are very importent factors determining dose distribution in radiation therapy of electron beam. Radiotherapy traetment planning using computed tomography in Breast cancer are able to ideal dose distribution. Authors concluded as following. 6MeV energy of electron beam propered below 1.5cm in chest wall's thickness or internal mammary lymphnode's depth. 9MeV energy of electron beam from 1.5cm to 2.0cm. 12 MeV energy of electron beam from 2.0cm to 2.5cm.

  • PDF

Self-Aligned $n^+$ -pPolysilicon-Silicon Junction Structure Using the Recess Oxidation (Recess 산화를 이용한 자기정렬 $n^+$ -p 폴리실리콘-실리콘 접합구조)

  • 이종호;박영준;이종덕;허창수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.6
    • /
    • pp.38-48
    • /
    • 1993
  • A recessed n-p Juction diode with the self-aligned sturcture is proposed and fabricated by using the polysilicon as an n$^{+}$ diffusion source. The diode structure can be applicable to the emitter-base formation of high performance bipolar divice and the n$^{+}$ polysilicone mitter has an important effect on the device characteristics. The considered parameters for the polysilicon formation are the deposition condition. As$^{+}$ dose for the doping of the polysilicon and the annealing condition using RTP system. The vertical depth profiles of the fabricated diode are obtained by SIMS and the electrical characteristics are analyzed in terms of the ideality factor of diode (n), contact resistance and reverse leakage current. In addition, n$^{+}$-p junction diodes are formed by using the amorphous silicon (of combination of amorphous and polysiliocn) instead of polysilicon and their characteristics are compared with those of the standard sample. The As$^{+}$ dose for the formation of good junction is about 1~2${\times}10^{16}cm^{2}$ at given RTA conditions (1100.deg. C, 10sec).

  • PDF

Statistical Analysis Using Living Radiation Survey Data on Processed Products (가공제품에 대한 생활주변방사선 실태조사 자료를 활용한 통계분석)

  • Choi, Kyoungho;Cho, Jung Keun
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.123-128
    • /
    • 2020
  • Radiation Following the 2011 Fukushima nuclear accident in Japan, public interest and anxiety about radiation safety increased, and vague anxiety about commonly exposed living radiation was generated. The Atomic Energy Safety Commission has been conducting a survey of processed products that advertise "negative ions" and "far-infrared" emissions under the Living Radiation Safety Management Act. In this study, in-depth analysis was performed from a statistical point of view using the measurement data presented in the Nuclear Safety Committee's actual survey analysis report as secondary data. As a result, there was a statistically significant difference (p<0.005) between latex and civil affairs products. There were also statistically significant differences (p<0.05) in the results of testing whether there were significant differences in the annual exposure dose between groups after categorizing 71 civil products, including radon beds, into bed, bedding, and living and other categories. The correlation analysis results also confirm that, as is commonly known, the annual doses received from processed products are associated with radon derived from U-238 and Th-232.

A Study on High Energy Ion Implantation for Retrograde Well Formation (Retrograde Well 형성을 위한 고에너지 이온주입에 대한 연구)

  • 윤상현;곽계달
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.5
    • /
    • pp.358-364
    • /
    • 1998
  • Retrograde well is a new process for ULSI fabrication. High energy ion implantation has been used for retrograde well formation. In this paper the forming condition for retrograde well using high energy ion implantation is compared with that for conventional well. TW signals for retrograde p-,n-well($900^{\circ}C$),after annealing are similar trends to those of conventional ones($1150^{\circ}C$), however the signals for RTA have the highest value because of small thermal budget. Junction depths of retrograde well are varied from about 1.2 to $3.0\{mu}m$ as for conventional well. The peak concentrations of retrograde well, however, are about 10 times higher in values than those of conventional ones so that they can be used as any types of potential barriers or gettering sites. The critical dose for phosphorus implantation in our experiments is between $3\times10^{13} and 1\times10^{14}/cm^2$. Under the above critical dose, there are many secondary defects near projected range such as dislocation lines and dislocation loops.

  • PDF

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF

Evaluation of Dosimetric Leaf Gap (DLG) at Different Depths for Dynamic IMRT (동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석)

  • Chang, Kyung Hwan;Kwak, Jungwon;Cho, Byungchul;Jeong, Chiyoung;Bae, Jae Beom;Yoon, Sang Min;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • This study is to evaluate thedosiemtric leaf gap (DLG) at different depths for dynamic intensity-modulated radiation therapy (IMRT) in order to evaluate the absolute dose and dose distribution according to the different positions of tumors and compare the measured and planned the multileaf collimator (MLC) transmission factor (T.F.) and DLG values. We used the 6 MV and 15 MV photon beam from linear accelerator with a Millenium 120 MLC system. After the import the DICOM RT files, we measured the absolute dose at different depths (2 cm, 5 cm, 10 cm, and 15 cm) to calculate the MLC T. F. and DLG. For 6 MV photon beam, the measured both MLC T. F. and DLG were increased with the increase the measured depths. When applying to treatment planning systemas fixed transmission factor with its value measured under the reference condition at depth of 5 cm, although the difference fixed and varied transmission factor is not significant, the dosiemtric effect could be presented according to the depth that the tumor is placed. Therefore, we are planning to investigate the treatment planning system whichthe T. F. and DLG factor according to at the different depths can be applied in the patient-specific treatment plan.