References
- Otto K: Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 35:310-317 (2008) https://doi.org/10.1118/1.2818738
- Xing L, Thorndyke B, Schreibmann E, Yang Y, Li TF, Kim GY, Luxton G, Koong A: Overview of image-guided radiation therapy. Med Dosim. 31:91-112 (2006) https://doi.org/10.1016/j.meddos.2005.12.004
- Yoon SM, Lim YS, Park MJ, et al: Stereotactic body radiation therapy as an alternative treatment for small hepatocellular carcinoma. PLoS One. 8:e79854 (2013) https://doi.org/10.1371/journal.pone.0079854
- Kantz S, Sohn M, Troeller A et al: Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments. RadiatOncol. 10:184 (2015)
- Yu CX1, Li XA, Ma L, et al: Clinical implementation of intensity- modulated arc therapy. Int J RadiatOncolBiol Phys. 53:453-63 (2002)
- Huq MS, Das IJ, Steinberg T, Galvin JM: A dosimetric comparison of various multileaf collimators. Phys Med Biol. 47:N159-70 (2002) https://doi.org/10.1088/0031-9155/47/12/401
- Williams MJ, Metcalfe P: Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system. Phys Med Biol. 51:N65-78 (2006) https://doi.org/10.1088/0031-9155/51/4/N03
- Mohan R, Jayesh K, Joshi RC, et al: Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams. J Med Phys. 33:114-8 (2008) https://doi.org/10.4103/0971-6203.42757
- Wu QJ, Wang Z, Kirkpatrick JP, et al: Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions. RadiatOncol. 21:4 (2009)
- Hong CS, Ju SG, Kim M, et al: Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer. Med Phys. 41:021712 (2014) https://doi.org/10.1118/1.4860155
- Sharma DS, Dongre PM, Mhatre V, Heigrujam M: Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT. J ApplClin Med Phys. 12:3475 (2011)
- LoSasso T, Chui CS, Ling CC: Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys. 25:1919-27 (1999)
- Wijesooriya K, Bartee C, Siebers JV, et al: Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: implications for 4D radiotherapy. Med Phys. 32:932-41 (2005) https://doi.org/10.1118/1.1876581
- Shang Q, Qi P, Ferjani S, Xia P: Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodes. Med Phys. 40:061701 (2013) https://doi.org/10.1118/1.4803499
- Kumaraswamy LK, Schmitt JD, Bailey DW, et al: Spatial variation of dosimetric leaf gap and its impact on dose delivery. Med Phys. 41:111711 (2014) https://doi.org/10.1118/1.4897572
- Kielar KN, Mok E, Hsu A, Wang L, Luxton G: Verification of dosimetric accuracy on the TrueBeamSTx: rounded leaf effect of the high definition MLC. Med Phys. 39:6360-71 (2012) https://doi.org/10.1118/1.4752444
- Yao W, Farr JB: Determining the optimal dosimetric leaf gap setting for rounded leaf-end multileaf collimator systems by simple test fields. J ApplClin Med Phys. 16(4):5321 (2015)
- Lee JW, Choi KS, Hong S, et al: Effects of static dosimetric leaf gap on MLC-based small-beam dose distribution for intensity- modulated radiosurgery. J Appl Clin Med Phys. 8:2397 (2007)
- Mei X, Nygren I, Villarreal-Barajas JE: On the use of the MLC dosimetric leaf gap as a quality control tool for accurate dynamic IMRT delivery. Med Phys. 38:2246-55 (2011) https://doi.org/10.1118/1.3567148
- Szpala S, Cao F, Kohli K: On using the dosimetric leaf gap to model the rounded leaf ends in VMAT/RapidArc plans. J ApplClin Med Phys. 15:4484 (2014)
- Wasbo E, Valen H: Dosimetric discrepancies caused by differing MLC parameters for dynamic IMRT. Phys Med Biol. 53(2):405-15 (2008) https://doi.org/10.1088/0031-9155/53/2/008
Cited by
- Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations vol.27, pp.3, 2016, https://doi.org/10.14316/pmp.2016.27.3.111