• 제목/요약/키워드: denture base resin

검색결과 178건 처리시간 0.019초

Thermocycling이 Cobalt-Chromium 합금과 의치상 레진의 결합강도에 미치는 영향 (THE EFFECTS OF THERMOCYCLING ON THE BOND STRENGTH BETWEEN COBALT-CHROMIUM ALLOY AND DENTURE BASE RESIN)

  • 이수연;방몽숙
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.38-49
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of thermocycling on the shear bond strength of Co-Cr alloy to denture base resin. PMMA denture base resin such as heat-cured $Vertex-RS^{(R)}$, self-cured $Vertex-SC^{(R)}$ and 4-META denture base resin such as heat-cured $Meta-Dent^{(R)}$, self-cured $Meta-Fast^{(R)}$ was bonded to Co-Cr alloy. Samples were divided into 3 groups : no thermocycling group as control, thermocycling between $5^{\circ}C\;and\;55^{\circ}C$ with 15 second dwell time as group 1, thermocycling with 1 minute dwell time as group 2. The shear bond strength was measured and the interface between metal and resin was observed by SEM. The results were as follows. 1. The shear bond strength decreased significantly according to thermocycling and dwell time(P<0.001). 2. The bond strength of Co-Cr alloy and 4-META denture base resin was significantly higher than that of Co-Cr alloy and PMMA denture base resin(P<0.001) 3. In SEM, there was no gap in control group, but there was much and large gap in group 1, 2. The longer dwell times, the lower bond strength. PMMA denture base resin had more gap than 4-META denture base resin in the interface. These results revealed that thermocycling decreased the bond strength between Co-Cr alloy and denture base resin and dwell time of thermocycling changed the effect of thermocycling. The results suggested that oral temperature change affect the bond strength of prosthesis.

  • PDF

키토산을 첨가한 의치상 재료의 세균 부착에 관한 연구 (ADHERENCE OF ORAL BACTERIA ON CHITOSAN-ADDED DENTURE BASE MATERIALS IN VITRO)

  • 정승환;방몽숙;박하옥
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.525-535
    • /
    • 2002
  • The purposes of this study were to evaluate the adherence of bacteria on various denture base resin materials and effects of chitosan, added to denture base materials on bacterial adherence. PMMA denture base resin such as heat-cured Vertex-RS, self-cured Vertex-SC and 4-META denture base resin such as heat-cured Meta-Dent, self-cured Meta-Fast were used in this study Samples were divided into two groups the denture base resin with chitosan, without chitosan Streptococcus mutans and Lactobacillus casei were used in this study. The surface of samples was observed by SEM. When chitosan was added to M17 and MRS broth, viable cell count of bacteria was reduced. Viable cell count of Streptococcus mutans on the samples decreased as follows : Meta-Dent, Vertex-SC, Meta-Fast, Vertex-RS. Viable cell count of Lactobacillus casei on the samples decreased as follows: Vertex-RS, Meta-Dent, Meta-Fast, Vertex-SC. The resin with chitosan showed lower adherence of bacteria than without chitosan. The images of SEM showed that the surface of the resin with chitosan was rougher than that of without chitosan. These results showed that the denture base resin materials with chitosan have rougher surface than without chitosan, but less bacteria adhered on them.

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구 (A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials)

  • 조성윤;송영균
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.232-243
    • /
    • 2021
  • 목적: 다양한 3D 프린팅 의치상 레진과 여러 가지 의치 첨상 재료 간의 전단결합강도를 평가하여 기존의 열중합 의치상 레진과의 전단결합강도를 비교 평가하고자 하였다. 연구 재료 및 방법: 열중합레진(Vertex RS)과 3D프린팅 의치상 레진 두종(DENTCA Denture base II, NextDentTM Base)을 사용하였다. 의치 첨상 재료로는 성분이 다른 총 4종(Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit)을 사용하여 12개의 군으로 분류하였다. ISO/TS 11405규격에 따라 접착을 시행하였다. 전단결합강도를 측정하였고, 이후 입체현미경과 주사전자현미경을 이용하여 접착 계면을 관찰하고 파절편의 분석을 통하여 파절 양상을 조사하였다. 결과: 3D 프린팅 의치상 레진 군에서 의치 첨상 재료와의 전단결합강도가 열중합레진 군에 비해 유의하게 낮은 전단결합강도 결과를 나타내었다(P < 0.05). Polymethyl methacrylate계열의 첨상재료의 경우, 의치상종류와 관계없이 높은 전단결합강도를 보였다. 파절 양상은 대부분의 군에서 접착성 파절이 나타났고 일부 군에서 응집성 파절과 혼합성 파절 양상이 나타났다. 결론: Polymethyl methacrylate를 주성분으로 하는 의치 첨상 재료가 실험에 사용된 모든 의치상 레진에서 다른 의치 첨상 재료와 비교하여 높은 전단 결합강도 값을 나타내었지만, 직접법으로 의치 첨상을 시행할 경우 단량체로 Isobutyl methacrylate 성분의 의치 첨상재료를 사용하는 것이 전단결합강도면에서 유리할 것으로 사료된다.

화학적 표면처리에 따른 의치상 레진과 이장재 간의 전단 결합강도 (Effects of chemical surface treatment on the shear bond Strength of denture reliners and denture base resin)

  • 최에스더;권은자
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5745-5751
    • /
    • 2013
  • 본 논문은 monomer에서 결합증진에 많은 역할을 하는 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면 처리한 것이 의치상 레진과 이장재간의 결합력에 미치는 영향에 대해 알아보고자 하였다. 의치상 레진에 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면처리 후 이장재를 주입하여 전단결합강도를 측정하였다. MMA와 TEGDMA의 농도별 표면 처리에 따른 의치상 레진과 이장재간의 전단결합강도에서는 Vertex self curing resin에서 95%, 90%, 80%, Kooliner에서는 95%, 90%에서 유의적으로 높게 나타났다(P<0.05). 또한, silane coupling agent 5%로 표면 처리한 그룹이 Vertex self curing resin과 Kooliner 모두에서 전단결합강도가 유의적으로 높게 나타났다(P<0.05). 따라서 적절한 화학적 표면 처리는 의치상 레진과 이장재간의 결합력 증가에 영향을 미치리라 사료된다.

의치용 인공치아와 의치상용 레진간의 결합강도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE BOND STRENGTH OF DENTURE TEETH BONDED TO DENTURE BASE MATERIALS)

  • 이주희;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.464-474
    • /
    • 1996
  • A principal advantage of a plastic tooth over a porcelain tooth should be its ability to bond to the denture base material. But plastic teeth could craze and wear easily, so more abrasion resistant plastic denture teeth have been developed. To resist abrasion, the degree of cross-linking was increased, but bonding to denture base meterial became more difficult. The purpose of this study was to evaluate the bond strength of plastic teeth and abrasion resistant teeth bonded to heat-curing, self-curing and light-curing denture base material. Denture tooth molds were chosen that had a>8mm diameter. The denture teeth was bonded to three denture base materials and then machined to the same dimensions. Three denture base materials were used as control groups. Prior to tensile testing, the specimens were thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ for 1000cycles. Tensile testing was performed on an Instron Universal testing mechine. Experimental group ; plastic teeth(Justi Imperial)+heat-curing resin(Lucitone 199) plastic teeth(Justi Imperial)+light-curing resin(Triad) plastic teeth(Justi Imperial)+self-curing resin(Vertex SC) abrasion resistant teeth(IPN)+heat-curing resin(Lucitone 199) abrasion resistant teeth(IPN)+light-curing resin(Triad) abrasion resistant teeth(IPN)+self-curing resin(Vertex SC) Control group ; heat-curing resin(Lucitone 199) light-curing resin (Triad) self-curing resin(Vertex SC). The results were as follows : 1. The denture teeth bonded to heat-curing resin showed the cohesive failure and those bonded to the other resins showed adhesive failure. 2. Tensile bond strength of the plastic teeth bonded to self-curing resin was not significantly greater than bonded to light-curing resin(p>0.05). 3. Tensile bond strength of the abrasion resistant teeth bonded to self-curing resin was not significantly greater than bonded to light-curing resin(p>0.05). 4. Tensile bond strength of the plastic teeth to self-curing resin was not significantly different from that of the abrasion-resistant teeth(p>0.05). 5. Tensile bond strength of the plastic teeth to light-curing resin was significantly greater than that of the abrasion resistant teeth(p<0.01).

  • PDF

실버 설파다이아진이 첨가된 의치상용 레진의 Candida albicans에 대한 항균평가 및 물성 평가 (Evaluation of the physical properties and antibacterial effects on Candida albicans of denture base resin containing silver sulfadiazine)

  • 최유리;강민경
    • 한국치위생학회지
    • /
    • 제23권6호
    • /
    • pp.459-466
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the physical properties and antibacterial activity of denture base resin with added silver sulfadiazine. Methods: Specimens were made from self-curing denture base resin and silver sulfadiazine as an inorganic antibacterial agent. For physical evaluation of the specimens, surface roughness, surface hardness, and contact angle were measured. Bacterial growth was assessed by optical densityat 600 nm (OD600) and colony forming units (CFU) measurements to confirm antibacterial activity. Results: There was no significant difference in surface roughness, surface hardness, and contact angle in the experimental group containing silver sulfadiazine compared to the control group. In contrast, the experimental group showed a significant decrease in antibacterial activity compared to the control group in terms of OD value. Analysis of CFU confirmed a significant decrease in colonies in the experimental group compared to the control group. Conclusions: Denture base resin containing silver sulfadiazine, an inorganic antibacterial agent, exhibited enhanced antibacterial activity without physical changes. In conclusion, the use of denture base resin containing inorganic antibacterial agents may be expected in the future.

합성수지 인공치와 열중합의치상 Resin의 결합시 인공치에 형성하는 유지공의 효과에 관한 연구 (The effect of retention grooves in Acrylic resin tooth denture base bond)

  • 김부섭
    • 대한치과기공학회지
    • /
    • 제9권1호
    • /
    • pp.51-55
    • /
    • 1987
  • One of the primary advantages of acrylic resin teeth is their ability to bond chemically to the denture base resins. Fracture od acrylic resin teeth from a maxillary denture, however, is not uncommon. Bonding failures have been attributed to faulty boil-out procedures that fail to eliminate all traces of wax from the ridge lap surfaces of the teeth and to contamination of the ridge lap surface by careless application of tinfoil substitute. Attempts to increase the strength of the bond between acrylic resin teeth and heat-cured denture base resin include grinding the glossy ridge lap surface (in fluid system), painting the ridgelap surface of the teeth with monomer-polymer solution, and cutting retention grooves in the ridge lap surface of the teeth. This latter method has been tested by applying a tensile force in a labial direction to the incisal part of the lingual surface of the acrylic resin teeth. A progressive shear compressive load was applied at an angle to the lingual surface of acrylic resin teeth bonded to denture base acrylic resin. No statistically singificant advantage was derived by preparing retention grooves of different shapes in the ridgelap surface of the denture teeth.

  • PDF

A COMPARATIVE STUDY ON THE DIMENSIONAL CHANGE OF THE DIFFERENT DENTURE BASES

  • Kim, Myung-Joo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.712-721
    • /
    • 2006
  • Statement of problem. Acrylic resin is most commonly used for denture bases. However, acrylic resin has week points of volumetric shrinkage during polymerization that reduces denture fit. The expandability of POSS (Polyhedral Oligomeric Silsesquioxane) containing polymer could be expected to reduce the polymerization shrinkage of denture bases and would increase the adaptability of the denture to the tissue. Purpose. The purpose of this study was to compare the dimensional stability in the conventional acrylic resin base, POSS-containing acrylic resin base, and metal bases. Materials and methods. Thirty six maxillary edentulous casts and dentures of different base were fabricated. Tooth movement and tissue contour change of denture after processing (resin curing, deflasking, decasting and finishing without polishing) and immersion in artificial saliva at $37^{\circ}C$ for 1 week and 4 weeks were measured using digital measuring microscope and threedimensional laser scanner. Results. The results were as follows: 1. The conventional resin group showed significant (p<0.01) dimensional change throughout the procedure (processing and immersion in artificial saliva). 2. After processing, the metal group and POSS resin group showed lower linear and 3-dimensional change than conventional resin group (p<0.01). 3. There was no statistically significant linear and 3-dimensional change after immersion for 1 week and 4 weeks in metal and POSS resin group. 4. In all groups, the midline and alveolar ridge crest area presented smaller 3-dimensional change compared with vestibule and posterior palatal seal area after processing and soaking in artificial saliva for 1 week and 4 weeks (p<0.01). Conclusion. In this study, a reinforced acrylic-based resin with POSS showed good dimensional stability.

레진 표면 처리제의 도포에 따른 의치상 레진과 개상용 레진의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF REBASE RESIN TO DENTURE BASE RESIN BY APPLICATION OF PRIMERS)

  • 문병준;방몽숙
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.50-63
    • /
    • 1998
  • This study investigated the effects of resin surface primers for rebase resins on the surface texture of denture base resins by the use of scanning electron microscopy. This study also evaluated the bond strength of rebase resins to denture base resin. The denture base resin in this study was Vertex RS (Dentimex Co., Ltd., Holland). The rebase resins used were Tokuso Rebase (Tokuyama Co., Ltd., Japan), Metabase (Sun Medical Co., Ltd., Japan), New True Liner(Harry J, Bosworth Co., Ill.), and Reverse (Nissin Co., Ltd., Japan). The test samples were divided into four parts: Group 1 : Treated with primer with brush. Group 2 : Immersed in the primer for 5 seconds. Group 3 : Immersed in the primer for 10 seconds. Group 4 : Immersed in the primer for 30 seconds. Control group : not treated with primer The results were as follows; 1. The bond strength of rebase resins to denture base resin is increased by application of primers. 2. Regardless of the rebase resin type, there was no significant difference among the bond strength in groups G1, G2, G3, G4. There was a significant difference with the control. (P<0.05) 3. Regardless of each group, the bond strength according to the rebase resin type was decreased in the following order: Tokuso Rebase, New Tru Liner, Reverse and then Metabase. 4. Under the scanning electron microscope, brush application produced a softening of the denture base surface. After immersion, all primers produced a spongelike structure on the denture base resin surface. The results of this study suggest that primers produce a significant effect by means of brush application, therefore it is recommended as the most convenient and logical procedure for application of the primers.

  • PDF