• Title/Summary/Keyword: dental

Search Result 24,265, Processing Time 0.055 seconds

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Structural equation modeling for association between patient satisfaction and quality of life after implant surgery (임플란트 만족도와 삶의 질 간의 관련성에 대한 구조방정식모델 분석)

  • Chung, Sun-Young;Cho, Jin-Hyun;Lee, Kyu-Bok;Choi, Youn-Hee;Song, Keun-Bae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.291-299
    • /
    • 2011
  • Purpose: This study was designed to measure patient satisfaction and oral health-related quality of life and to assess an association between patients' satisfaction and oral health-related quality of life after implant surgery by using structural equation modeling. Materials and methods: A total of 257 participants who visited 6 dental clinics located in Daegu city for the purpose of implant treatment participated in this study. Six months after completion of implant surgery, the patients' satisfaction and oral health-related quality of life were surveyed. The effect of factors associated with patients' satisfaction such as functions and aesthetics, maintenance and cost on oral health-related quality of life after implant surgery was analyzed using AMOS 4.0. Results: Oral health-related quality of life was improved in all dimensions of OHIP-14 after implant surgery. Functions and aesthetics as well as maintenance had a significant effect on oral health-related quality of life (P<.05), while cost was not a critical factor influencing oral health-related quality of life. Conclusion: High satisfaction with functional aspects and maintenance aspects significantly affected good quality of life. The result of this study supported the fact that education and management for patients after implant therapy were positively related to good quality of life based on a theoretical model.

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

AN INVESTIGATION OF TRAUMATIC DENTAL INJURIES IN CHILDREN (소아의 치아와 지지조직 외상에 관한 분석)

  • Baik, Byeong-Ju;Yang, Yeon-Mi;Yang, Cheol-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.600-612
    • /
    • 2001
  • The purpose of this study is concerned with an investigation of the actual condition of traumatic injuries of teeth and supporting structures in children to set up possible criteria for prevention and treatment of injured teeth. The materials consisted of the clinical records of 431 traumatically injured teeth of 212 children, accumulated during two years from the first of April in 1998 to the end of March in 2000, supplied from the Dept. of Pediatric Dentistry, Chonbuk National University Hospital. The incidence of injuries in boys was extremely high for permanent teeth, twice as high as in girls. Accidents to primary teeth were most common from 1 to 2 years of age and to permanent teeth were most from 8 to 9 years of age. The most common cause of trauma was a fall for both primary and permanent teeth, followed by collision. The anterior teeth in maxilla was most frequently affected by trauma in both the primary and permanent teeth. The most common type of trauma were loosening for the primary teeth, followed by luxation types which included the intrusion, displacement and extrusion and complete avulsion types. For the permanent teeth, the most common type of trauma were tooth fracture. The most common trauma of soft tissue was laceration of upper lip, lower lip and gingiva of maxilla Concerning treatment at the first visit, primary teeth with only loosening and concussion were not usually treated. Permanent teeth were often treated by crown restorations for crown fractures and by endodontic procedures for pulpal exposure. Though we could elucidate actual condition of traumatic injuries of teeth in children, we should make a follow-up survey to ensure the prognosis of injured teeth and establish the most desirable criteria for traumatized teeth in children.

  • PDF

A STUDY ON THE ENAMEL EROSION BY FERMENTED MILKS (수종 유산균 발효유의 법랑질 침식효과에 대한 연구)

  • Sim, Jeung-Ho;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.555-563
    • /
    • 2004
  • The pH of beverages is known to be low and have, therefore, been implicated in the increasing incidence of erosion. Erosion is believed to be the predominant cause of teeth wear in children and young adults, although there will always be a contribution from attrition and abrasion. The aim of the present study was to evaluate the effect of yogurt on the progression of erosive demineralization in human enamel using demineralization model in vitro. In 4 yogurts, available on the market, pH, buffering capacity and the concentrations of calcium, phosphate and fluoride were determined. The buffering effect was determined by titration with NaOH. 50 milliliters of each drink was then titrated with 1M sodium hydroxide, added in 0.5 milliliters increments, until the pH reached about 7. Human deciduous enamel(n=40) samples were divided into four groups and exposed to 80ml of the yogurt for 30,60, 90 and 120min. Enamel surface microhardness(VHN) was examined before and after each exposure. 1. The average PH of fermented milk was 3.77 and this pH value was acidic enough to cause tooth erosion. 2. All of the fermented milks were found to be erosive(p<0.05) 3. The teeth exposed to the fermented milk all showed erosion like lesions and microhardness measurements showed that enamel surface hardness decreased proportionately with increased time of immersion in all tooth specimen groups. 4. After immersion for 30 and 60 minutes, reduction rate of microhardness values was not significantly different between the groups(p>0.05). However, after 90 and 120 minutes, reduction rate of each group was significantly different(p<0.05).

  • PDF

THE RELATIONSHIP BETWEEN THE CONGENITALLY MISSING PRIMARY LOWER ANTERIOR TEETH AND THEIR SUCCEDANEOUS PERMANENT TEETH IN KOREAN CHILDREN (한국 어린이에서 하악 유절치와 그 계승 영구치의 선천적 결손 간의 관계)

  • Kim, Hyun-Jin;Hyun, Hong-Keun;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • Many studies have shown that there is a strong relationship between the congenitally missing primary teeth and their succedaneous permanent teeth. However, especially in case of lower anterior region, we can observe the existence of permanent teeth even though their precedent primary teeth were missed at times. The purpose of this study was to reveal the relationship between the congenitally missing primary lower anterior teeth and their succedaneous permanent teeth in Korean children. Total of 14,307 children, under 6 years of age, who attended the department of pediatric dentistry, Seoul National University Dental Hospital, Seoul, Korea from January 1st 2005 to September 5th 2008 were radiologically examined using the panoramic x-ray in order to analyze the relationship between the congenitally missing primary lower anterior teeth and their succedaneous permanent teeth. The results were as follows : 1. The prevalence of congenitally missing lower anterior teeth in primary dentition was 0.24%. The odds ratio of both the primary and permanent anterior teeth being present was 7163.5 and only the permanent anterior teeth being present was 0.79. 2. The percentage of all succedaneous permanent teeth being present was 44.12% in cases of missing lower primary anteriors. The odds ratio of at least one succedaneous permanent teeth being present in cases of bilateral primary anterior teeth missing was 1.57 times more common than in cases of unilateral primary teeth missing. 3. The odds ratio of primary missing teeth being unilateral was 2.2 times higher in females. Moreover, the odds ratio of succedaneous permanent teeth being present in cases of primary teeth missing was 2.22 times higher in males.

Diagnosis and Effect of Maxillary Expansion in Pediatric Sleep-Disordered Breathing (소아 수면호흡장애의 진단과 상악확장술의 치료효과)

  • Kim, Doyoung;Baek, Kyounghee;Lee, Daewoo;Kim, Jaegon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.369-381
    • /
    • 2019
  • The aim of this study was to analyze the changes and improvements in symptoms of sleep-disordered breathing (SDB) using semi-rapid maxillary expansion (SRME) in children with narrow maxilla and SDB symptoms. Subjects were 15 patients with sleep disorder (apnea-hypopnea index, AHI ≥ 1) and narrow maxillary arch between 7 and 9 years of age. Before the SRME was applied, all subjects underwent pediatric sleep questionnaires (PSQ), lateral cephalometry, and portable sleep monitoring before expansion (T0). All subjects were treated with SRME for 2 months, followed by maintenance for the next 3 months. All subjects had undergone PSQ, lateral cephalometry, and portable sleep monitoring after expansion (T1). Adenoidal-nasopharyngeal ratio (ANR), upper airway width and hyoid bone position were measured by lateral cephalometry. The data before and after SRME were statistically analyzed with frequency analysis and Wilcoxon signed rank test. As reported by PSQ, the total PSQ scale was declined significantly from 0.45 (T0) to 0.18 (T1) (p = 0.001). Particularly, snoring, breathing, and inattention hyperactivity were significantly improved (p = 0.001). ANR significantly decreased from 0.63 (T0) to 0.51 (T1) (p = 0.003). After maxillary expansion, only palatopharyngeal airway width was significantly increased (p = 0.035). There was no statistically significant difference in position of hyoid bone after expansion (p = 0.333). From analysis of portable sleep monitoring, changes in sleep characteristics showed a statistically significant decrease in AHI and ODI, and the lowest oxygen desaturation was significantly increased after SRME (p = 0.001, 0.004, 0.023). In conclusion, early diagnosis with questionnaires and portable sleep monitoring is important. Treatment using SRME will improve breathing of children with SDB.