• 제목/요약/키워드: cut tree

검색결과 219건 처리시간 0.028초

The First Case of Successful Bark Implantation of a 250-year-old Zelkova Tree Heavily Damaged by Artificial Girdling

  • Ryu, Seong Ho;Kim, Gyoung Hee;Koh, Young Jin
    • 식물병연구
    • /
    • 제24권3호
    • /
    • pp.237-241
    • /
    • 2018
  • A circular bark with a 30 cm width was artificially removed from the trunk of a 250-year-old zelkova tree (Zelkova serrata) heavily damaged by artificial girdling in Sunchang, Jeonbuk Province in March of 2005. The debarked area was cleaned approximately 10 days after artificial girdling and bark margins with 2 cm width above and below the girdled portion were cut off to promote wound callus formation. Nine pieces of fresh bark (width 8 cm, length 35 cm, thickness 0.5 cm) were then prepared from branches of neighbor zelkova trees broken by heavy snowfalls and pasted onto the girdled portion of the tree, after which a Vaseline dressing was applied to water-proof the area and rubber bars were used to hold the implants to the trunk. Two pieces of the implanted fresh barks were successfully grafted onto the girdled area and the damaged tree has been vigorously growing over 13 years. To our knowledge, this is the first case of successful bark implantation to cure a 250-year-old zelkova tree heavily damaged by artificial girdling. This bark implantation technique will be utilized for the conversation and management of heavily damaged big and old trees in the future.

로봇 운동방정식과 감도해석 (Dynamic Equations of Robots and Sensitivity Analysis)

  • 송성재;이장무
    • 한국정밀공학회지
    • /
    • 제12권6호
    • /
    • pp.105-111
    • /
    • 1995
  • The inverse dynamic equations for 5 link robot including a closed chain have been derived. The closed chain is virtually cut open, and the kinematics and dynamics of the virtual open chain robot are analyzed. The constraints are applied to the virtually cut joints by the Jacobian matrix which represents the configuration of the closed chain. The topology of tree structrued open chain robot is described by a FATHER array. The FATHER array of a link indicates the link tha tis connected in the direction of base link. Based on the inverse dynamic equations, the torque sensitivity models of the 5 link robot have been developed. The sensitivity models characterize the sensitivity of the driving torque with respect to the link parameters. All the procedures are illustrated through the 2 link robot.

  • PDF

선릉 정자각 목부재의 연륜연대 분석 (Tree-Ring Dating of Wood Elements for Jeongjagak of Seonreung, Seoul, Korea)

  • 손병화;한상효;박원규
    • 한국가구학회지
    • /
    • 제23권2호
    • /
    • pp.222-228
    • /
    • 2012
  • Seonreung is the tomb of Seong-jong (A.D. 1457~1494), the 9th king of Joseon Dynasty (1392-1910) and his second queen Jeonghyeon-wanghu (1462~1530). We obtained dendrochronological dates of Jeongjagak (ceremonial hall) of Seonreung. It was known first built in 1495 and reconstructed in October 1706, We obtained tree-ring dates of 20 wood elements (beams, pillars, truss posts, cant strips, roof boards and roof loaders). Their outermost rings were dated from 1630 to 1705. The dates of bark rings in four elements were A.D. 1705 with completed latewoods, indicating that these woods were cut some time between the autumn of 1705 and spring of 1706. The results confirmed the reconstruction date Jeongjagak of Seonreung in 1706, suggesting that there was not so long period for wood drying or storage, i.e., less than 6 months. The dates of outermost rings prior to 1705 in other elements indicated that some outer rings of these elements were removed during wood processing. Tree-ring dating proved that the present Jeongjagak of Seonreung had been well preserved for more than 300 years.

  • PDF

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.

XLPE의 전기트리 열화에 따른 전기적특성의 변화 (Change of electrical properties of XLPE with electirical-tree degradation)

  • 강동식;류희석;선종호;최선도;이호진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2136-2138
    • /
    • 1999
  • In this study, we describe the change of electrical properties of XLPE with electrical-tree degradation. XLPE insulation was used as specimen which was cut off from 22.9kV XLPE insulated cable and made in a type of block. The applying voltages are 8kV, 10kV, 12kV and frequency is 60Hz Ogra needles having tip radius of 10$\mu\textrm{m}$ were inserted in blocks. PD quantity and $tan{\delta}$ and DC current were measured from inception of tree to breakdown and their characteristics were analyzed.

  • PDF

FTA기법을 이용한 콤프레서 고장진단 (Diagnosis of Compressor Failure by Fault Tree Analysis)

  • 배용환;이석희;최진원
    • 대한기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.127-138
    • /
    • 1994
  • The application of fault tree technique to the analysis of compressor failure is considered. The techniques involve the decomposition of the system into a form of fault tree where certain basic events lead to a specified top event which signifies the total failure of the system. In this paper, fault trees are made by using fault train of screw type air compressor failure. The fault trees are used to obtain minimal cut sets from the modes of system failure and, hence the system failure rate for the top event can be calculated. The method of constructing fault trees and the subsequent estimation of reliability of the system is illustrated through compressor failure. It is proved that FTA is efficient to investigate the compressor failure modes and diagnose system.

RBD와 FTA의 논리구조와 신뢰성 중요도의 고찰에 의한 시스템 비시간가동률 개선방안 (Improvement Strategy of System Unavailability by Review of Logical Structure and Reliability Importance of Reliability Block Diagram (RED) and Fault Tree Analysis (FTA))

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제13권3호
    • /
    • pp.45-53
    • /
    • 2011
  • The research proposes seven elimination rules of redundant gates and blocks in Fault Tree Analysis (FTA) and Reliability Block Diagram (RBD). The computational complexity of cut sets and path sets is NP-hard. In order to reduce the complexity of Minimal Cut Set (MCS) and Minimal Path Set (MPS), the paper classifies generation algorithms. Moreover, the study develops six implementation steps which reflect structural importance (SI) and reliability importance (RI) from Reliability Centered Maintenance (RCM) that a priority of using the functional logic among components is to reduce (improve) the system unavailability (or availability). The proposed steps include efficient generation of state structure function by Rare Event Enumeration (REA). Effective use of importance measures, such as SI and ill measures, is presented based on the number and the size of MCS and MPS which is generated from the reference[5] of this paper. In addition, numerical examples are presented for practitioners to obtain the comprehensive understanding of six steps that is proposed in this research.

화학공정의 사고 빈도 분석 S/W 개발 (Development of Accident Frequency Analysis S/W for Chemical Processes)

  • 서재민;신동일;고재욱
    • 한국가스학회지
    • /
    • 제3권3호
    • /
    • pp.29-33
    • /
    • 1999
  • 본 연구는 정량적 위험 평가의 기반 조성을 위해서 다양한 위험 평가 기법 중에서 이상 트리 분석(Fault Tree Analysis) 방법을 이용하여 빈도 분석 프로그램을 개발하였다. 빈도 분석 프로그램을 구축하기 위하여 계산 과정에서는 gate-by-gate 방법과 부울 대수 (Boolean algebra) 방법을 이용하였고, minimal cut set 방법을 이용하여 사고 발생 경로를 정량적으로 표현하였다 결론적으로 본 연구에서 개발한 빈도 분석 프로그램을 이용하여 사고 발생 빈도를 낮출 수 있다면 공정 전체의 안전성을 높이는데 큰 도움이 될 것이며, 기존에 사용되고 있는 외국의 S/W를 대체할 수 있을 것이라고 사료된다.

  • PDF

형태 제약과 출입구를 고려한 설비 배치 및 복도 구조 디자인 (Factory Layout and Aisle Structure Design Considering Dimension Constraints and Door Locations)

  • Chae-Bogk Kim
    • 산업경영시스템학회지
    • /
    • 제26권3호
    • /
    • pp.58-66
    • /
    • 2003
  • The cut tree approach of Montreuil and Ratliff [16] and eigenvector approach [10] are used to automatically draw a feasible facility layout with aisle structure. The department arrangement can minimize an aisle distance criterion considering door locations and dimension constraints. The aisle distance is measured by the door to door distance between departments. An eigenvector and cut tree approaches [1] are implemented based on the branch and bound technique in Kim et al. [2] in order to obtain feasible layouts. Then, the algorithm to fix the door location of each department is developed. After the door locations are determined, the factory layout is evaluated in terms of aisle distance. The aisle structure is obtained by expanding the original layout. The solution is kept until we will find better factory layout. The proposed approach based on the branch and bound technique, in theory, will provide the optimal solution. If the runs are time and/or node limited, the proposed method is a strong heuristic. The technique is made further practical by the fact that the solution is constrained such that the rectangular shape dimensions length(l) and width(w) are fixed and a perfect fit is generated if a fit is possible.

FTA를 적용한 태양광 발전 및 ESS 연계형 PCS의 안전성 평가 (Safety Assessment for PCS of Photovoltaic and Energy Storage System Applying FTA)

  • 김두현;김성철;김의식;남기공;정천기
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.14-20
    • /
    • 2019
  • This paper presents a safety assessment based approach for the safe operation for PCS(Power Conditioning System) of photovoltaic and energy storage systems, applying FTA. The approach established top events as power outage and a failure likely to cause the largest damage among the potential risks of PCS. Then the Minimal Cut Set (MCS) and the importance of basic events were analyzed for implementing risk assessment. To cope with the objects, the components and their functions of PCS were categorized. To calculate the MCS frequency based on IEEE J Photovolt 2013, IEEE Std. 493-2007 and RAC (EPRD, NPRD), the failure rate and failure mode were produced regarding the basic events. In order to analyze the top event of failure and power outage, it was assumed that failures occurred in DC breaker, AC breaker, SMPS, DC filter, Inverter, CT, PT, DSP board, HMI, AC reactor, MC and EMI filter and Fault Tree was drawn. It is expected that the MCS and the importance of basic event resulting from this study will help find and remove the causes of failure and power outage in PCS for efficient safety management.