Change of electrical properties of XLPE with electirical-tree degradation

XLPE의 전기트리 열화에 따른 전기적특성의 변화

  • Published : 1999.07.19

Abstract

In this study, we describe the change of electrical properties of XLPE with electrical-tree degradation. XLPE insulation was used as specimen which was cut off from 22.9kV XLPE insulated cable and made in a type of block. The applying voltages are 8kV, 10kV, 12kV and frequency is 60Hz Ogra needles having tip radius of 10$\mu\textrm{m}$ were inserted in blocks. PD quantity and $tan{\delta}$ and DC current were measured from inception of tree to breakdown and their characteristics were analyzed.

Keywords