• 제목/요약/키워드: current sampling

검색결과 822건 처리시간 0.029초

최소 차원 상태 관측기를 사용한 전류 제어형 PWM 인버터에 관한 연구 (Current Controlled PWM Inverter Using Reduced-Order State Observer)

  • 김종석;이채동;박욱상;최선영;김영철;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.300-302
    • /
    • 1995
  • This paper describes a current control method for a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. For the deadbeat current controller, the system's order becomes a high order and increases computation delay time. Therefore, The delay time produces current ripple. To minimize the current ripple, a new method based on deadbeat control theory for current regulation is proposed. It is constructed by a reduced-order state observer which predicts the output current in next sampling instant.

  • PDF

노래연습장, 유흥·단란주점의 음악저작물이용 실태조사 개선안 연구 (An Improved Sample Design for Estimating the Usage of Copyrighted Music Works)

  • 이계오;정연수
    • Communications for Statistical Applications and Methods
    • /
    • 제19권3호
    • /
    • pp.315-331
    • /
    • 2012
  • 2011년 3월 오프라인 노래연습장, 유흥 단란주점 표본조사업소에서 수집한 곡목별 히팅수 로그데이터로부터 강남지부 등 총 11개 지부의 히팅수와 히팅수 표본오차를 추정하였다. 업소에서 징수한 음악저작물 사용료를 추정된 곡목별 히팅수를 기준으로 관계권리자(작곡, 작사, 편곡자 등)에게 분배하는 현행 분배방식에 따라 표본오차 규모를 금액으로 환산하여 크기를 검토하였다. 기존표본은 과소하여 히팅수 추정시 표본오차를 과다하게 발생시켰으며, 본 연구에서는 히팅수 추정오차를 줄여 음악저작권사용료 분배에 형평성을 기할 수 있는 합리적인 표본크기 개선방안을 제안하였다.

위치 기반 시스템을 위한 CMOS IR-UWB RFIC (A CMOS IR-UWB RFIC for Location Based Systems)

  • 이중무;박명철;어윤성
    • 전자공학회논문지
    • /
    • 제52권12호
    • /
    • pp.67-73
    • /
    • 2015
  • 본 논문에서는 근거리 위치 기반 시스템을 위한 3 - 5 GHz IR-UWB(impulse radio-ultra wide band) RFIC를 제안한다. 수신기의 구조는 에너지 검출 방식으로 설계되었고, 고속 sampling을 하기 위해서 4 bit ADC 와 DLL(delay locked loop) 을 이용하여 equivalent-time sampling 기술을 사용하도록 설계되었다. 송신기는 저전력의 디지털 UWB impulse generator 를 설계하였다. 설계된 IR-UWB RFIC 는 CMOS $0.18{\mu}m$ 공정을 이용하여 제작되었다. 측정된 수신기의 감도는 -85.7 dBm 이며, 송신기와 수신기는 1.8 V 전원 전압에서 각각 32 mA 와 25.5 mA 의 전류를 소모한다.

Full-color Non-hogel-based Computer-generated Hologram from Light Field without Color Aberration

  • Min, Dabin;Min, Kyosik;Park, Jae-Hyeung
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.409-420
    • /
    • 2021
  • We propose a method to synthesize a color non-hogel-based computer-generated-hologram (CGH) from light field data of a three-dimensional scene with a hologram pixel pitch shared for all color channels. The non-hogel-based CGH technique generates a continuous wavefront with arbitrary carrier wave from given light field data by interpreting the ray angle in the light field to the spatial frequency of the plane wavefront. The relation between ray angle and spatial frequency is, however, dependent on the wavelength, which leads to different spatial frequency sampling grid in the light field data, resulting in color aberrations in the hologram reconstruction. The proposed method sets a hologram pixel pitch common to all color channels such that the smallest blue diffraction angle covers the field of view of the light field. Then a spatial frequency sampling grid common to all color channels is established by interpolating the light field with the spatial frequency range of the blue wavelength and the sampling interval of the red wavelength. The common hologram pixel pitch and light field spatial frequency sampling grid ensure the synthesis of a color hologram without any color aberrations in the hologram reconstructions, or any loss of information contained in the light field. The proposed method is successfully verified using color light field data of various test or natural 3D scenes.

공공측량 성과심사 자동화를 위한 결정트리 알고리즘의 적용 (Application of Decision Tree Algorithm for Automating Public Survey Performance Review)

  • 현미진;진철;박명진;최현
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.333-341
    • /
    • 2024
  • The current public survey performance review extracts samples according to the set screening ratio, and examines the extracted samples to determine the suitability or inadequacy of the survey performance. The examiner directly judges the survey performance submitted by the performer, and extracts it in consideration of various field conditions and topography for each subject. However, it is necessary to secure fairness in the examination as it is extracted with different extraction methods for each subject and the judgment of the examiner. Accordingly, in order to automate sampling for public survey performance review, the detailed sampling criteria of the reviewer were investigated to prepare a volume calculation table, and the automation of sampling using Python was studied. In addition, by reviewing items that can and cannot be automated, the application of the automated decision tree algorithm of sampling was reviewed.

히스테리시스 특성을 고려한 측정용 변류기 2차 전류 보상 알고리즘 (Compensating Algorithm for the Secondary Current of a Measurement CT Considering the Hysteresis Characteristics of the Core)

  • 강용철;정태영;장성일;김용균;소순홍
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1709-1714
    • /
    • 2007
  • This paper proposes a compensating algorithm for the secondary current of the measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the measurement CT. The exciting current can be decomposed into the magnetizing current and the core loss current. The core loss current is obtained from the measured secondary current and the core loss resistance. The core flux linkage is calculated by integrating the measured secondary current, and then inserted into the flux-magnetizing current curve to obtain the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and then added to the measured current to obtain the correct current. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the measurement CT.

2차 전압-철손 전류 곡선과 자속-자화 전류 곡선을 고려한 측정용 변류기 2차 전류 보상 알고리즘 (Compensating algorithm for the secondary current of a measurement type CT considering the secondary voltage-core loss current curve and the flux linkage-magnetizing current curve)

  • 강용철;정태영;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.65-66
    • /
    • 2008
  • This paper proposes a compensating algorithm for the secondary current of the measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. The proposed algorithm decomposes the exciting current into the magnetizing current and the core loss current and each of them is estimated. The core loss current is calculated from the secondary voltage and the secondary voltage-core loss current curve. The core flux linkage is calculated and then inserted into the flux-current curve to estimate the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and then added to the measured current to compensate the secondary current. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The test results of the real CT were also included. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the CT.

  • PDF

A simplified method to determine the chloride migration coefficient of concrete by the electric current in steady state

  • Lin, K.T.;Yang, C.C.
    • Computers and Concrete
    • /
    • 제13권1호
    • /
    • pp.117-133
    • /
    • 2014
  • This study presents a rapid method for determining the steady state migration coefficient of concrete by measuring the electric current. This study determines the steady state chloride migration coefficient using the accelerated chloride migration test (ACMT). There are two stages to obtain the chloride migration coefficient. The first stage, the steady-state condition was obtained from the initial electric current at the beginning of ACMT. The second stage, the average electrical current in the steady state condition was used to determine the steady state chloride migration coefficient. The chloride migration coefficient can be determined from the average steady state current to avoid sampling and analyzing chlorides during the ACMT.

Current Uniformity Enhancement for AMOLED Data Driver IC

  • Bae, Han-Jin;Bae, Joon-Ho;Choi, Byong-Deok;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1436-1439
    • /
    • 2005
  • A novel current-type data driver for active matrix organic light emitting diode (AMOLED) is proposed for current uniformity enhancement among its output channels. New architecture is composed of shadow DACs that precharge output stages, a single-real DAC that correct the output level to a real target current level and output stages that operate in 3 states of sampling, correcting and driving. Simulation results show that the proposed driving method and circuits improve the current uniformity among output channels of a current-type driver IC.

  • PDF

예측전류제어방식을 이용한 3상 능동전력필터에 관한 연구 (A Study on the Three-Phase Active Power Filter using Predictive Current Control Method)

  • 권병기;우명호;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.138-140
    • /
    • 1994
  • In this paper, a three-phase active power filter using voltage- source PWM converter is designed to eliminate the harmonics and compensate the reactive power in the ac side. The predictive current control method is adopted, which provides constant switching frequency and low current ripple but has inherently one sampling error between the command and the actual current. Here we propose the algorithm which corrects this delay time. The converter voltage obtained from this current control can be accomplished by the space vector modulation method at a voltage-type converter. All control sequences of active filter is executed by a DSP which is designed to calculate floating points at very hight speed. Finally, the validity of this filter using the predictive current control method is demonstrated through experimental results.

  • PDF