ZnO 피뢰기 소자의 저항분 누설전류 측정 및 분석 (A Measurement and Diagnosis for Resistive Leakage Current of ZnO Arrester Element)

  • 이복희;강성만;박진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2155-2157
    • /
    • 1999
  • This paper describes a new measurement method of resistive current and the technique of deterioration diagnosis for ZnO element. The consequence of current increasing (resistive current) with time is the eventual attainment of a state of thermal instability that may lead to arrester failure. So, it is very important to measure a leakage current of ZnO arrester installed at on-state. For the high-precision and more reliability, an iron core, which has a very high relative permeability, was used for increasing detection sensitivity, and we also used the personal computer for the data storage and program and analysis. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

불평형전류 측정에 의한 회전기 열화감시장치 (Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines)

  • 박찬용;박대원;류길수;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF

개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템 (Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques)

  • 손진근;서일동;전희종
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.

온도측정에 의한 산화아연형 피뢰기 진단 (ZnO Arrester Diagnosis by Measurement of Temperature)

  • 길경석;한주섭;송재용;서황동;문승보;박태곤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.361-364
    • /
    • 2005
  • In this paper, surface temperatures of ZnO arresters as a function of ambient temperatures and leakage currents were experimentally investigated. The variations of the leakage current was below 10 uA, which comes about $4.5\%$ of the normal leakage current. Temperature differences between the ambient and the surface of arresters were not shown until $150\%$ to the normal leakage current, and were remarkable over $200\%$. From the results, we deduced a couple of polynomials which enables the calculation of the leakage current by the measurement of surface temperature. Tests on used arresters have shown the same results as the experimental one. Also, we expect that an arrester diagnosis is possible by measuring the surface temperature of them after more studies on the effect of wind, moisture penetration, and arrester types.

전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술 (Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor)

  • 이상화;강전홍;김명수;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

변전소 고조파 측정 및 분석에 관한 연구 (A Study on Measurement and Analysis of Harmonics in Substation)

  • 한무호;박태준;이성희;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

터널내 구간별 지하수 유입량 산정방법 : 유속계의 이용 (Calcu;ation of Groundwater Inflow Rates with respect to the Subusection of Tunnel: Application of the Current Meter)

  • 조병욱
    • 자원환경지질
    • /
    • 제32권6호
    • /
    • pp.661-667
    • /
    • 1999
  • Estimation of inflow rates into subsection of a tunnel is establishing the proposed grouting part, measuring the degree of grouting, and settling the dispute over deplrtion of groundwater which may be resulted from tunneling. A current meter was used to calculate inflow rates of groundwater to each subsection of the tunnel. The study area is composed of section 1 and 2 of Imha-Youngchun waterway trnnel which has 32.976km length, with each section having 3,745m and 4,079m, respectively. The depth from groung surface to tunnel ranges from 122.45m to 358.3m. Total inflow rates of groundwater into each section measured three times by the current meter, together with bottle and eye measurement, were compared with groundwater inflow rates of each section measured by datalogger. The calcuated inflow rates of the sections by bottle and eye measurement were 8.8%∼54.7% of inflow rate (averaging 27,4%), whwewas those by the current meter were 76.9%∼110.6%(averaging 92.9%). Therfore, the current meter is regarded as useful method to calculate groundwater inflow rates into subsections of a tunnel.

  • PDF

누설전류 측정을 이용한 부재수용가의 전기안전 점검 (Electrical Safety Inspection for Empty Houses Using Leakage Current Measurement)

  • 임용배;정종욱;정진수;조성원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.260-263
    • /
    • 2006
  • The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installations for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향 (Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement)

  • 길경석;한주섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

측정 영역에 관한 제7차와 현행 교과서 및 익힘책 비교 분석: 안내 정도와 측정의 주요 학습 요소를 중심으로 (A Comparative Analysis of the 7th and the Current Mathematics Textbooks and Workbooks on the Measurement Domain: Focused on the Degree of Guidance and Key Learning Elements)

  • 방정숙;김수경;최인영
    • 한국초등수학교육학회지
    • /
    • 제16권2호
    • /
    • pp.227-252
    • /
    • 2012
  • 본 논문은 그동안 별반 연구되지 않았던 측정 영역과 관련하여, 길이와 넓이를 대상으로 안내 정도와 측정의 주요 학습 요소를 분석 기준으로 하여 제7차와 현행 교육과정 자료를 비교분석하였다. 분석 결과 교과서와 익힘책에 제시된 안내 정도와 측정의 학습요소가 비슷한 점이 많았으나, 현행 교육과정 자료에서 안내형의 비율이 줄어들고 복합형과 개방형의 비율이 늘어난 점, 그리고 측정값 계산의 비율이 줄어들고 측정추론 양감 어림, 측정단위, 측정의 구성요소에 대한 비율이 늘어난 점이 차이점으로 드러났다. 이와 같은 연구결과를 토대로 본 논문은 측정 영역의 교과서 개정과 교과서 분석에 대한 시사점을 제시한다.