• 제목/요약/키워드: criteria for measurement

검색결과 913건 처리시간 0.025초

A Review of Media Argumentation: Roles of Background Knowledge in Critical Reading

  • Lee, Jong-Hee
    • 영어어문교육
    • /
    • 제15권4호
    • /
    • pp.157-175
    • /
    • 2009
  • This paper offers a critical review of a newspaper argument regarding the problems of high school education assessment for university entrance examination system in the United Kingdom. The media account raises three sets of questioning to hold that the nation's long-standing A-levels have failed and is no longer viable as a high-stakes test. However, it is found that the writer's argumentations involving misleading conceptions can be deconstructed because of invalid reasoning and unreliable evidence. So, it is proposed that a reasonable solution to replace the discredited A-level exams should be to adopt an eclectic approach for assessing candidates' multiple capabilities; performance, potentiality and critical thinking skills. These criteria for component-oriented assessments are designed to measure their high school academic achievements and intellectual capacity for tertiary education; in the process of such measurement, critical-logical reasoning abilities for sound judgment and problem-solving tasks should be incorporated with the basic precondition that each university possesses its own discretion for the determination of adequate proportions to reflect each of the assessment outcomes. It is, therefore, expected that this critical review will inspire the readers to understand aspects of assessment as an educational field and to confirm how seriously they may be misguided by a distorted media argumentation without substantive background knowledge.

  • PDF

히트파이프를 이용한 축열식 냉.난방 시스템에 관한 연구 (A Study of Storage Type Cooling and Heating System by Heat Pipe)

  • 김성실;함성철;이양호;최병윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2006
  • The heat pump system is attractive alternatives to conventional heating and cooling systems owing to their higher energy utilization efficiency. The thermal loads of commercial and institutional buildings are generally cooling-dominated. In this study have been developed ice storage type heat pump system for cooling and heating by heat pipe. This system was practiced performance test on evaluation criteria for heat storage systems. Accomplished the actual proof examination and looked into the performance of the system. In this study, measurement and analysis of ice storage type heat pump system for cooling and heating by heat pipe. The heat pump unit COP appears 3.05 for cooling and 4.20 for heating. As a result, the method to energy saving and to using a substitute energy actively that is heat pump cooling & heating system is expected by heat pipe. Thermal storage capacity appears $19.5RTH/m^3$ for cooling.

  • PDF

부하지속곡선을 이용한 중랑천의 유량 조건별 수질특성 평가 (Assessment of the Water Quality of Jungnang Stream by Flow Conditions Using Load Duration Curve)

  • 최경완;신경용;이형진;전상호
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.438-447
    • /
    • 2012
  • Objective: The objective of this study was to suggest a method through which load duration curve was used to assess the achievement of water quality targets in accordance with the criteria for pollutant load depending on flow rate variation. Methods: The stage-discharge curve and flow duration curve of Jungnang Stream were deduced. Using water quality targets and measurement of the stream, the flow duration curve was also drawn. Based on these, the feasibility of achievement of water quality targets in respect to flow rate was assessed. Results: In terms of the load duration curve of the stream, it was observed that excess of criteria for concentrations of $BOD_5$, $COD_{Mn}$ and SS frequently occurred. On the other hand, when the flow rate was low, the concentrations of T-N and T-P exceeded the criteria. Conclusions: Through the load duration curve, the overall water quality of Jungnang Stream was understood. When the flow rate is high, management of point source of $BOD_5$, $COD_{Mn}$ and SS is needed to achieve water quality targets for Jungnang Stream. On the other hand, when the flow rate is low, the management of non-point source T-N and T-P is necessary to attain the water quality goal.

공공 정보통신기술(ICT)사업의 투자 평가기준이 사업성공에 미치는 영향 (Effect of Investment Evaluation Criteria of Public ICT Projects on Business Success)

  • 김용걸;이상연;채명신
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권4호
    • /
    • pp.157-169
    • /
    • 2021
  • 공공 정보통신기술(ICT)사업의 투자 평가 체계를 세우는 것은 궁극적으로 정부 재정이 투자되는 공공 ICT사업의 성공률을 높이고 사업의 활성화를 꾀함으로써 국가 경제 성장 기반 구축 및 글로벌 ICT산업 경쟁력을 제고 하는 것이다. 본 연구에서는 기존 평가 체계에 따라 수립된 공공 ICT사업 투자 평가 요인이 실제 사업 성공에 미치는 영향을 실증적으로 검증하고, 향후 투자 평가 요인에 대한 방향을 제시하고자 하였다. 선행 연구를 통해 공익성, 경제성, 기술성, 정책성 및 예산효율성 등 다섯 개의 평가 요인을 도출하였고, 이를 실제 사업에 직접 참여했던 전문가들의 설문을 통해 이러한 평가 기준이 실제 사업 성공에 미치는 영향을 검증하였다. 또한 ICT사업의 투자 평가 요인과 사업성공 사이에서 정부의 지원제도에 대한 조절 작용 여부도 확인하였다. 측정 도구의 신뢰도 및 타당도, 구조 모형 분석, 경로 분석 등을 실증분석하고, 기존 ICT 투자 평가 요인의 유의성을 검증하였다.

아동용 성취동기 척도 개발에 관한 연구 (A study on the development of the children′s motivation of achievement Scale)

  • 박성옥;기현주;신귀순
    • 영재교육연구
    • /
    • 제14권1호
    • /
    • pp.1-27
    • /
    • 2004
  • 본 연구는 국가의 경제발전은 물론 대인관계와 사회적응에 매우 중요한 역할을 하는 성취동기 중 아동의 성취동기를 측정할 수 있는 척도를 개발하고자 하였다. 서울시내 초등학교 2곳에 재학중인 5,6학년 아동 586명을 대상으로 설문지 조사를 실시하였다. 예비 연구를 통하여 구성된 81개 문항의 척도를 문항 변별도 측면에서 양호한 수준 $x^2$의 유의도 p<.01과 .25이상 V계수의 68개 문항을 추출하였다. 68개 문항을 요인 분석하여 고유치 1이상, 요인부하량 .30이상인 49개 문항을 추출한 후 회귀분석을 적용한 결과 설명력의 증가분이 3%미만인 13개 문항을 척도 구성에서 제외시켜 총 36개 문항으로 아동의 성취동기 최종 측정 척도가 개발되었다. 척도의 신뢰도는 문항 내적일치도 지수인 Cronbach의 $\alpha$계수로 산출하였는데, .85로 만족할 만한 수준으로 나타나 개발된 척도가 우리나라 아동의 성취동기를 측정하기 위한 유용한 도구로 검증되었다.

교량구조물의 헬스모니터 링을 위한 진동계측 (Instrumentation and Structural Health Monitoring of Bridges)

  • 김두기;김종인;김두훈
    • 한국소음진동공학회논문집
    • /
    • 제11권5호
    • /
    • pp.108-122
    • /
    • 2001
  • As bridge design is advancing toward the performance-based design. it becomes increasingly important to monitor and re-evaluate the long-term structural performance of bridges. Such information is essential in developing performance criteria for design. In this research. sensor systems for long-term structural performance monitoring have been installed on two highway bridges. Pre1iminary vibration measurement and data analysis have been performed on these instrumented bridges. On one bridge, ambient vibration data have been collected. based on which natural frequencies and mode shapes have been extracted using various methods and compared with those obtained by the preliminary finite element analysis. On the other bridge, braking and bumping vibration tests have been carried out using a water truck In addition to ambient vibration tests. Natural frequencies and mode shapes have been derived and the results by the breaking and bumping vibration tests have been compared. For the development of a three dimensional baseline finite element model, the new methodology using a neural network is proposed. The proposed one have been verified and applied to develop the baseline model of the bridge.

  • PDF

대기오염측정에 대한 정도관리의 필요성 - 1998년도 한국대기환경학회 측정분석분과회의 실험실간 비교분석사업 시행과 전개방향 (The Need for QA/QC in the Measurements of Airborne Pollutants - Conduction of and Directions towards an Interlaboratory Comparison Test in 1998 by the Measurement and Analysis Division of KOSAE)

  • 김기현;이강웅;김조천;서영화;이종해;허귀석
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.63-69
    • /
    • 1999
  • To offer a general guideline for the quantitative analysis of airborne pollutants, we designed and conducted a comprehensive QA/QC test using two different strategic approaches, namely (1) field-based comparative measurement and (2) laboratory-based comparative analysis. The former task was performed to make meaningful comparison of combined errors occurring from both sampling and analytical techniques in the measurements of such components as: (1) criteria pollutants, (2) volatile organic compounds (VOCs), and (3) particulate matters with the associated metals and ions. The latter task was also conducted to compare various types of bias arising mainly from the laboratory analytical procedures of (1) gaseous standards of VOCs and (2) of aqueous standards of metals and ions. The concentration data derived from each of these two different types of major tasks were evaluated per chemical species categorized as above. While the very details of these studies are to be reported on an individual basis according to the above classification of the project, this paper is presented to provide an overview of the whole project - its aim and direction.

  • PDF

A study for the characteristics of milli-gloss variation of unprinted coated paper and objective measurement tools for it

  • Jeon, Sung J.;Song, Yo H.;Lee, Jae S.;Shim, Gyu S.
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2000년도 춘계학술발표논문집
    • /
    • pp.118-125
    • /
    • 2000
  • Gloss uniformity on unprinted coated papers is oftenly called as 'Surface Feeling' in market and roles as a very important criteria when a customer choose a paper. However, there is few researches on this quality so far and even there isn't much knowledge on the characteristics of gloss variation, ie what it is, where it comes from etc. Therefore, there should be a pre-research on its characteristics, factors, measuring method or tools prior to the following development activities. In this paper, we obtained about a dozen of papers including foreign products and measured not only basic properties of them, but also various characteristics related to ununiformity. Our experiments went further to printing, but that area is excluded in this paper. Also, we investigated several instruments for measuring gloss variation by an objective way all over the world and tested with our own samples so that we tried to find out which one is best-correlated with visual appreciation and suggest its results as possible. We found out several things from these experiments including what is difference between good and bad gloss uniformity, the factors of gloss variation, and the results of measurement for gloss variation with instruments.

  • PDF

제주 수변공간 조명계획을 위한 공원조명 실측과 해석 (Parks' Lighting Measurement and Analysis for Lighting Plan around Waterfront in Jeju)

  • 김일환;오성보;고봉운
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.116-122
    • /
    • 2017
  • 도시의 환경조명은 야간의 도시를 빛으로 장식하고 미화해서 아름답게 하며, 시민의 안전과 치안을 향상시켜 도시의 품위를 높여 주고 있다. 공원의 조명계획을 수립할 때 공원의 기능이나 성격을 충분히 고려해서 가장 좋은 조명효과를 얻을 수 있도록 조명방식을 이용하는 것이 중요하다. 또한 도시의 야간활동 증대와 경관에 대한 중요성이 높아지는 요즘 도심하천과 해안 수변공간에 대한 경관조명은 기능적인 측면과 더불어 주체성 향상에 중요한 역할을 한다. 이 논문은 수변에 접해 있는 홍콩의 흥험 산책로를 통해 침사추이 산책로 까지 중요 지점에서 조명을 실측 하였고, 일본의 후쿠오카 나카가와 공원을 중심으로 중요 지점으로 파악되는 장소에서 조명 측정을 하였다. 그리고 제주시 함덕해수욕장 진입로 주변과 상가와 인접한 도로를 중심으로 실측하여 조명환경 특성을 비교 분석을 하였다. 분석 결과 홍콩의 경우는 8개 평가항목에서 우수하였고, 후쿠오카의 경우 5개 항목에서 양호함을 보여 보통으로 분석되었다. 그리고 제주시의 경우는 다수의 항목에서 보통과 미흡으로 평가되어 전체적으로 열악한 실정으로 판단되었다. 이를 통하여 지역 주민의 야간 활동을 고양시키고 방문자들에게 아름다운 경관을 제공할 수 있는 제주시 수변공간의 안정적인 조명계획을 제안하고자 한다.

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.