• Title/Summary/Keyword: correlation consistency

Search Result 577, Processing Time 0.031 seconds

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

A Study of Bleaching Phenomenon of Otter (Lutra lutra) Spraints in Relation to Weather Conditions and Characteristics of Sprainting Sites (기상조건과 배설지 특성에 따른 수달(Lutra lutra) 분변의 표백현상에 관한 연구)

  • Noh, Eun-Young;Han, Sung-Yong;Yoo, Jeong-Chil
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • The bleaching phenomenon of otter spraints is indicates that the age of spraints (fresh or old spraints). As previous studies on the old otter faeces (spraint) have focused only on the external changes of spraints, it has been difficult to explain the difference of the decomposition rates among old spraints. We hypothesized that the micrometeorology difference caused by various characteristics of sprainting sites such as porosity and consistency of soil could affect the extent of the decomposition rate, the solar bleaching phenomenon of spraints used as a measure of the patterns of old spraints. Sprainting sites were classified into four types (Clay, Sand, Rock and Concrete spot) and each type was divided into two groups according to the sunlight condition (Sunny site and Shady site) to measure the effect of solar radiation. Micrometeorology of the sites were evaluated by measuring temperatures and humidities of the sites during the whole season. The variations in micrometeorology of the sunny sites according to the sprainting site types were examined with correlation analyses between the factors of micrometeorology. The analyses on the bleaching phenomenon of the spraints by micrometeorology showed that the highest rate of bleaching was found at the 'Rock spot' and 'Concrete spot' of the sunny site and especially in summer, the highest rate of bleaching ($63.4{\pm}7.6%$) was found at the 'Clay spot' of the sunny sites. The lowest rate of bleaching was found at the 'Sand spot' of the sunny sites. The above findings show that the difference in bleaching rates among sprainting sites was due to the seasonal or sunny condition. In addition, we found that the differences in thermal conductivity among sprainting site characteristics have resulted in different sprainting site temperature which have affected the rate of bleaching of spraints. In conclusion, this study suggests that studies of otters on their population size and home ranges using spraints as an indirect sign, should consider the effects of sprainting site characteristics and weather conditions.

Nitrogen Efficiency and its Relation to Various Physiological Characteristics among Rice Varieties (수도품종간(水稻品種間) 질소효율(窒素効率) 및 수종(數種) 생리적특성(生理的特性)과의 관계(關係))

  • Park, Hoon;Mok, Sung Kyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.8 no.2
    • /
    • pp.105-111
    • /
    • 1975
  • Nitrogen efficiency for grain yield(E) and its relation to grain yield(Y), harvesting index(HI), percent translocation of nitrogen from straw to grain(T), nitrogen uptake amount(N), concentration in grain (GN%) or straw (SN%) and total dry matter yield (TY) among rice varieties (Oryza sativa, old and new varieties) were investigated at four nitrogen nutritional status (high and low fertilizer levels in high and low fertility fields) by simple correlation analysis. Relation between any two of above parameters or total dry matter yield (TY) and nitrogen efficiency for total dry matter yield (TE) was also investigated. 1. E is significantly and positively correlated with T, Y, HI but negatively with SN%, N, GN% and in negative trend with TY. 2. T is significantly and positively with GN% or Y, but negatively with SN%. 3. TE is significantly and positively correlated with TY but negatively with N. 4. The order of E among varieties showed consistency among different nitrogen nutritional environments. 5. From the above facts it was concluded that high yielding varieties have high nitrogen efficiency due to high percent translocation of nitrogen from straw to grain, subsequent low nitrogen concentration in straw and that translocated nitrogen in grain is greatly diluted with photosynthates. 6. Reported physiological characteristics of newly bred high yielding IR lines are well accordance with their high nitrogen efficiency and rice breeding was a selection on the basis of nitrogen efficiency. 7. It is postulated that high nitrogen efficiency varieties for yields have high nitrogen efficiency for root growth in early stage so that uptake more efficient soil nitrogen in later growth stage.

  • PDF

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Characteristics of Vertical Ozone Distributions in the Pohang Area, Korea (포항지역 오존의 수직분포 특성)

  • Kim, Ji-Young;Youn, Yong-Hoon;Song, Ki-Bum;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.3
    • /
    • pp.287-301
    • /
    • 2000
  • In order to investigate the factors and processes affecting the vertical distributions of ozone, we analyzed the ozone profile data measured using ozonesonde from 1995 to 1997 at Pohang city, Korea. In the course of our study, we analyzed temporal and spatial distribution characteristics of ozone at four different heights: surface (100m), troposphere (10km), lower stratosphere (20km), and middle stratosphere (30km). Despite its proximity to a local, but major, industrial complex known as Pohang Iron and Steel Co. (POSCO), the concentrations of surface ozone in the study area were comparable to those typically observed from rural and/or unpolluted area. In addition, the findings of relative enhancement of ozone at this height, especially between spring and summer may be accounted for by the prevalence of photochemical reactions during that period of year. The temporal distribution patterns for both 10 and 20km heights were quite compatible despite large differences in their altitudes with such consistency as spring maxima and summer minima. Explanations for these phenomena may be sought by the mixed effects of various processes including: ozone transport across two heights, photochemical reaction, the formation of inversion layer, and so on. However, the temporal distribution pattern for the middle stratosphere (30km) was rather comparable to that of the surface. We also evaluated total ozone concentration of the study area using Brewer spectrophotometer. The total ozone concentration data were compared with those derived by combining the data representing stratospheric layers via Umkehr method. The results of correlation analysis showed that total ozone is negatively correlated with cloud cover but not with such parameter as UV-B. Based on our study, we conclude that areal characteristics of Pohang which represents a typical coastal area may be quite important in explaining the distribution patterns of ozone not only from surface but also from upper atmosphere.

  • PDF

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Development of the Korean Form of Zung's Self-Rating Anxiety Scale (한국형 자가평가 불안척도의 개발)

  • Lee, Jung-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.279-294
    • /
    • 1996
  • This study was carried out to develop a Korean language version of Zung's self-rating anxiety scale(SAS) from august, 1994 to September, 1996. The subjects consisted of 205 normal control subjects from the general population group, and 97 subjects with anxiety disorders. These 97 subjects were chosen from a group by the structured clinical interview for DSM-IV of in patients and out patients. Both normal control subjects and anxiety disorder subjects were drawn utilizing a cluster of sampling methods. In order to analyze the data on anxiety scores, Pearson's product moment correlation coefficient method was carried out, as well as reliability, factor analysis and discriminant function analysis, utilizing the SPSS/PC+ program. The results obtained were as follows: The mean average of the total anxiety scores were 32.36 + 6.35 for the normal control subjects and 50.53 + 7.67 for anxiety disorder subjects. Test-retest reliability(coefficient r=0.98, p < 0.001), and internal consistency(coefficient r=0.96, p < 0.001) were satisfactory. Factor analysis using oblique technique rotation yielded four factors. The normal control subjects scored higher concerning the symptoms such as sweating, restlessness, apprehension, insomnia and dyspnea, and lower for faintness, mental disintegration, paresthesia, dizziness and tremor. On the other hand, for the anxiety disorders, apprehension, restlessness, sweating, dyspnea and insomnia scored higher, and lower for faintness, paresthesia, nightmare, dizziness and tremor.

  • PDF

The Reliability and Validity Studies of the Korean Version of the Perceived Stress Scale (한글판 스트레스 자각척도의 신뢰도와 타당도 연구)

  • Lee, Jongha;Shin, Cheolmin;Ko, Young-Hoon;Lim, JaeHyung;Joe, Sook-Haeng;Kim, SeungHyun;Jung, In-Kwa;Han, Changsu
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2012
  • Objectives : Perceived stress scale is a self-report inventory to estimate the degree of individual perceived stress in daily life. The aim of this study was to introduce this scale and test the reliability and validity of the Korean version of PSS. Methods : The total of 154 female hospital workers were included in this study. The survey questionnaires were conducted for demographic information. All participants were required to complete PSS, Hamilton Anxiety scale and Beck Depression Inventory. Reliability and validity studies were conducted and internal consistency was examined. Results : The mean score of the PSS reported in this sample was $20.69{\pm}4.56$. The overall Cronbach's alpha was 0.819, and the test-retest reliability coefficient was 0.66. PSS had a significant positive correlation with the HAM-A(r=0.49, p<0.01), and the BDI(r=0.55, p<0.01). Factor analysis yielded 2 factors with eigenvalues of 3.924 and 2.608, accounting for 65 percent of variance. Factor 1 represented "stress" and factor 2 represented "control of stress". Conclusions : This study indicates that the PSS is appropriate for estimating the perceived stress levels. These results support the use of PSS in large sections of the population in Korea.

  • PDF

Development and Validation of Inventory of the Anger-inducing Automatic Thoughts for Elementary School Children (아동용 분노유발 자동적 사고 검사의 개발과 타당화)

  • Kim, Seon-Hwa;Park, Gyoung-Mook
    • The Korean Journal of Elementary Counseling
    • /
    • v.9 no.1
    • /
    • pp.41-58
    • /
    • 2010
  • The purpose of this study was to invent anger-inducing automatic thoughts examination for elementary school children based on its investigation for Korean one. I made the anger-inducing Automatic Thoughts Questionnaire(I, II) and made an examination of the contents of the automatic thoughts with it. Based on it, with preliminary questionnaire 90, I did principal component analysis varimax rotation and then final anger-inducting automatic thoughts examination of 40 question in 2 primary factor construction was consisted. I made 300 students carry out it to know its reliability, propriety and made 100 students carry it out at 2-week intervals test-retest. I divided them in three groups as low, middle and high according to its soore regarding anger-inducting automatic thoughts, I confirmed the variation of each group in positive thoughts, self-esteem, life satisfaction, anger, the result is same as follows; First, the content of Anger-inducting Automatic thoughts for elementary school students is revealed as unreasonableness(56.4%), retailation and passive, active offense(16.3%), blame and contempt(11.9%), injured pride and refusal(9.2%), absurd(3.9%), abandonment and avoidance(2.1%), self-abasement in turn. Second, said inventory is consist of 2 notion; first(20 questions) is blame, retaliation and second(20 questions) is injustice. Inner-item consistency of total 40 question is .97, Split-half reliability is .93, Test-retest reliability is .86. Third, criterion validity is revealed fine by reviewing the correlation between existing index related to the inventory of Anger-inducting Automatic thoughts of the elementary school students. Moreover, to find out discriminant validity, I divided three classes(low, middle, high) according to the score of said thoughts. As a result, there is certain variations when I confirmed variations in groups by reviewing the self-esteem, positive way of thinking, life satisfaction, anger.

  • PDF

A Study on the Strategic Use of an IMC Planning Model for the Distribution Industry (유통업 IMC 기획모델의 전략적 활용에 관한 연구)

  • Mo, Sun-Jong;Song, In-Am
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.2
    • /
    • pp.113-145
    • /
    • 2008
  • Marketing for the distribution industry is making an ongoing progress in the changes of customers, the competitive environment, and the internal marketing environment. Integrated marketing communication activities are required for the enhancement of efficiency in the market.oriented activities. In this study, IMC is defined as "a notion that a market oriented business integrated marketing communication means, conducting and evaluating marketing activities with consistent messages in order to communicate with customers based on databases." In this study, an IMC planning model for the improvement of marketing efficiency in the distribution industry was derived from a pilot study. This model may be broken down into the following phases: IMC goals setting, situational analysis (customer analysis, competition analysis and company analysis), customer data analysis, contact management, budgeting, the establishment of an IMC strategy, the IMC mix and execution, an evaluation system, and feedback. In consideration of the characteristics of the distribution industry, this study was accompanied by a vocational study on IMC means employed by, in particular, department stores and other distributors such as: advertising, sales promotion, sales promotion advertising, direct marketing, public relations, personal selling, the Internet, mobile, visual merchandising, words of mouth. In addition, this study also covered the correlation among variables such as IMC activities of distributors, the process of forming customer's brand attitudes, brand loyalty and repurchase intention. This research would enhance the utilization of IMC. The analysis on customer's brand attitudes toward the IMC activities of distributors requires the simultaneous consideration of how they are linked to purchase as well as their attitudes toward both distributors and stores. The formation of brand loyalty and repurchase intention is related to the integration of marketing communication and the maintenance of consistency in contents, which requires integrated brand communication (IBC) strategies. IBC is a concept of using IMC means to manage the brand in a continuing and consistent manner and measuring their effect, which is a process to establish enterprise.level brand identity and maximize brand loyalty and repurchase intention by integrating IMC means. For an empirical analysis in this study, an online questionnaire survey was conducted among those department store customers from 20's to 50's who reside either in the Seoul and Gyeonggi areas and have made purchase at department stores. In this study, the research model consisted of four theoretical variables: IMC activities, IMC attitudes, brand loyalty, and repurchase intention, on which variables a pilot study was conducted. A number of hypotheses were constructed on the relations between IMC activities and IMC attitudes, between IMC attitudes and repurchase intention, and between brand loyalty and repurchase intention. The test of the hypotheses may be summarized as follows: Firstly, the test of the hypothesis concerning the relation between IMC attitudes and IMC activities - advertising, sales promotion, direct marketing, public relations, personal selling, the Web, mobile, visual merchandising, and word of mouth - indicates that advertising, sales promotion, direct marketing, public relations, personal selling, mobile, visual merchandising, and word of mouth have significant impact on IMC activities. In addition to the result similar to those of previous studies that such marketing communication means as word of mouth, advertising, personal selling and sales promotion, in particular, play very important roles, a notable finding of this study is that visual merchandising performed by department stores is shown to have very significant impact on IMC activities. On a separate note, it is also noteworthy that Internet marketing activities engaged by department stores are not shown to have significant impact on IMC attitudes. Secondly, the test of the hypothesis on the relation between IMC attitudes and brand loyalty attests that IMC attitudes for the distribution industry significantly affect brand loyalty. Thirdly, the test of the hypothesis concerning the relation between IMC attitudes and repurchase intention confirms that IMC attitudes for the distribution industry significantly affect repurchase intention. Fourthly, the test of the hypothesis concerning the relation between brand loyalty and repurchase intention indicates that brand loyalty significantly affect repurchase intention. A comprehensive view of these findings points to the conclusion that the IMC activities for the distribution industry do affect IMC attitudes, brand loyalty, and repurchase intention.

  • PDF