• 제목/요약/키워드: core loss

검색결과 1,001건 처리시간 0.037초

전기자동차용 3kW급 LDC를 위한 통합형 플라나변압기 설계 (Integrated Planar Transformer Design of 3 kW LDC for Electric Vehicles)

  • 라마단;석채영;김상진;최세완;유병우;박상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.157-159
    • /
    • 2020
  • This paper presents an optimal planar transformer design of a 3-kW Low voltage DC-DC Converter (LDC) with 3.68 kW/L power density for electric vehicle (xEV) application. The transformer is optimized based on the trade-off between footprint and loss using the proposed figure-of-merit (FOM) based optimization. In order to achieve ZVS under entire load range, an external leakage inductance is added and implemented using the proposed magnetic integration technique. A comparison between non-integrated and integrated magnetic core using finite element analysis (FEA) is presented. The result shows that the integrated core can reduce the core loss up to 35 % and core boxed volume up to 15 % compared to the non-integrated core. Experimental results are also provided to validate the proposed magnetic integration technique.

  • PDF

고에너지효율 연자성 복합 분말 소재의 연구개발 동향 (Research Trend of Soft Magnetic Composite Materials with High Energy Efficiency)

  • 김휘준
    • 한국자기학회지
    • /
    • 제21권2호
    • /
    • pp.77-82
    • /
    • 2011
  • 우리 삶의 질을 좌우하는 전자기 기기의 고기능화, 자동화, 소형화 추이에 따라 사용량이 급격히 증가하고 있는 연자성 소재로서 가장 널리 사용되고 있는 전기강판과 에너지 고효율화라는 시대의 요구에 따라 새롭게 부상되고 있는 연자성 복합 분말 소재에 대해 각 연자성 소재 분야에서 철손 제어 인자 및 이들 인자들의 제어 방안에 대해 문헌을 고찰했다. 전기강판에서는 히스테리시스 손실을 낮추기 위해 정련공정을 통해 자구이동을 방해하는 결함을 제거하고 결정립의 크기를 최적화하고 있으며, 와전류 손실의 감소를 위해 합금첨가원소를 통해 비저항을 높이고 판재의 두께를 박판화하고 있다. 이와 동시에 코팅을 통해 자구의 이동이 용이하도록 응력의 방향 및 크기를 제어하며, 압연기술과 열처리 기술을 통해 집합조직을 최적화하여 고투자율 및 저철손을 동시에 충족시켜 나가고 있다. 연자성 복합 분말 소재의 경우, 분말 표면의 복합화를 통해 철계 조성, 코팅, 윤활재 및 바인더, 성형 및 열처리 조건 등에 복합적으로 의존하는 연자성 코어의 최종 자기특성을 제어하고 있다. 온간 및 다단 성형과 같은 새로운 성형공정, 2단 소둔/자성 열처리와 같은 소둔 조건, 나노결정질, 비정질 및 벌크 비정질 등과 같은 새로운 조성, 적절한 코팅층의 변수들을 최적화할 경우, 연자성 복합 소재의 자성특성은 향상될 것으로 기대된다.

소구경 코어에 의한 콘크리트 압축강도 추정에 미치는 실험인자의 영향에 관한 연구 (A Study on the Influencing Factors on the Estimation of Compressive Strength by Small Size Core)

  • 한민철;김기정;백병훈;한천구;송성진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.361-364
    • /
    • 2002
  • This paper discusses the influencing factors such as coring position, height to diameter ratio of core specimen(h/d) and coring torque on the strength estimation of concrete by small site coring method in order to verify the validities of small size core method. According to results, as for the influence of drilling position, when core specimens are obtained from the place parallel to placing direction, compressive strength of core specimens are higher than those perpendicular to placing direction. This is due to the loss of the area of core specimen perpendicular to plating direction by bleeding. And in case of $\phi$ 24mm core specimen, when vertical drilling against placing direction is taken. compressive strength of core specimen obtained at the bottom of the structure is higher than that at the top of the structure. As for the influence of height to depth ratio, as h/d ratio increases compressive strength shows to be decreased. As for the influences of rotation speed of drilling machine, as its speed goes up, compressive strength decreases, regardless of core diameter.

  • PDF

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.49-54
    • /
    • 2002
  • HANARO, 30 MW of research reactor, was installed at the depth of 13m in an open pool. The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the cote. The rest, $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to prevent the radiated gas from being lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection, and increased the radiation lovel on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2 m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated at a higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated by Visual Basic Program. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss increased. And it was verified that the radiation level above was reduced mote safely by increasing the capacity of heater.

HEV/EV 전기강판 및 구동모터 특성해석 (Electrical steel and traction motor performance analysis for HEV/EV)

  • 김지현;김교성;김재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.812-813
    • /
    • 2011
  • This paper presents the characteristic of newly developed electrical steel and motor performance analysis for HEV/EV. This material is developed and optimized for high frequency operation to reduce the core losses in traction motors to increase fuel efficiency. Four types of electrical steel are introduced, which are optimized for high flux density (PNHF), high frequency low core loss (PNF), high punchability (PNS) and high strength (PNT) to meet different specifications from different types of traction motors. To identify the motor performance with this material, finite element analysis was used to calculate core loss as well as Ld and Lq for efficiency map. Also structure analysis was performed to calculate stress on bridge rotor.

  • PDF

DSP를 이용한 변류기 보상 알고리즘 (CT compensating algorithm Based on a Digital Signal Processor)

  • 강용철;이병은;소순홍;황태근;이지훈;차선희;김연희;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.255-257
    • /
    • 2005
  • This paper proposes a compensating algorithm of a measurement torrent transformer (CT) using DSP. The core flux is calculated and then magnetizing current is estimated in accordance with the flux-magnetizing current curve. The core loss current is obtained with the core loss resistance and the secondary voltage. The correct secondary current is estimated by adding the exciting current to the measured secondary current. The performance of the proposed algorithm was tested using EMTP generated data. The experiment on the real CT was conducted using the prototype compensated system based on a digital signal processor. The results indicate that the algorithm can increase the accuracy of the measurement CT significantly.

  • PDF

원자력발전소의 노심냉각회복 조치에 대한 운전원 조치시간 평가 (An Evaluation of Operator's Action Time for Core Cooling Recovery Operation in Nuclear Power Plant)

  • 배연경
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.229-234
    • /
    • 2012
  • Operator's action time is evaluated from MAAP4 analysis used in conventional probabilistic safety assessment(PSA) of a nuclear power plant. MAAP4 code which was developed for severe accident analysis is too conservative to perform a realistic PSA. A best-estimate code such as RELAP5/MOD3, MARS has been used to reduce the conservatism of thermal hydraulic analysis. In this study, operator's action time of core cooling recovery operation is evaluated by using the MARS code, which its Fussell-Vessely(F-V) value was evaluated as highly important in a small break loss of coolant(SBLOCA) event and loss of component cooling water(LOCCW) event in previous PSA. The main conclusions were elicited : (1) MARS analysis provides larger time window for operator's action time than MAAP4 analysis and gives the more realistic time window in PSA (2) Sufficient operator's action time can reduce human error probability and core damage frequency in PSA.

Phase Shift Full Bridge Converter for Sever Power using a New Separated Leakage Inductor Winding (SLW) Method

  • Cho, Kyu-Min;Kim, Young-Do;Cho, In-Ho;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.517-519
    • /
    • 2008
  • A new transformer winding method is proposed in this paper. Generally, PWM ZVS topologies use a leakage inductor to achieve ZVS operation. However, the leakage inductance of the transformer is not often enough to meet ZVS condition. Therefore, an additional leakage inductor is necessary, which causes large core loss because high input voltage is applied to the additional leakage inductor during a short commutation period. In this paper, a new separated leakage inductor winding (SLW) method is proposed. With the proposed winding method, a leakage inductor and a transformer can be combined in one ferrite core. Therefore, size and core loss of the additional leakage inductor can be reduced. Experimental results demonstrate that the proposed winding method can achieve a significant efficiency improvement in a 1210.8W (12V, 100.9A) prototype converter.

  • PDF

스테인레스 제강분진을 함유한 순철 압분코아의 자기특성 (Magnetic Properties of Powdered Fe Cores Containing Stainless Steel-making Dusts)

  • 김상원
    • 한국재료학회지
    • /
    • 제15권2호
    • /
    • pp.106-111
    • /
    • 2005
  • Effects of stainless steel-making dusts and binder content on compacting $density(\rho)$ and magnetic properties were evaluated. Cores compacted with the mixture of pure Fe powders, $5wt.\%$ dusts and $0.25wt.\%$ binder showed good AC magnetic properties. For example, permeability$({\mu}a)$ and core loss(P) of the cores containing $5wt.\%$ dusts at 500 kHz were 62 and $4008\;{\mu}W/cm^3$, respectively. These properties are almost equivalent to those of competitor's products (i.e, Ancorsteel TC 80 produced by $H\ddot{o}gan\ddot{a}s$ Corp.). The powdered cores obtained from the present work are expected to apply for high-performance soft magnetic components such as normal mode choke filter and pulse transformer.

유한요소법에 의한 권철심변압기의 철손해석 (Analysis of Iron Loss in a Wound Core Type Transformer by FEM)

  • 권병일;김성영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.21-23
    • /
    • 1995
  • The analysis of the thin lamination model of the wound core type transformer by FEM requires many region division and much calculationg time, and it has difficulty in calculation by modem computer. A new method which is simulated by a solid but anisotropic block with the magnetic permeabilities in the orthogonal dimension, is selected to account for the presence of the lamination.[1] Based on this equivalent anisotropic block model, we analyze the iron loss of the wound core type transformer by FEM, and compare the simulation results with the experimental results.

  • PDF