• Title/Summary/Keyword: copper particles

Search Result 261, Processing Time 0.03 seconds

Effect of Colloidal Silica and Pre-Coating of Cathode on Copper Electrodeposited Film (구리 전착층에 미치는 콜로이달실리카 및 음극 Pre-Coating의 영향)

  • Lee, Sang-Baek;Yun, Jeong-Mo;Park, Hyeong-Ho;Bae, In-Seong;Kim, Byeong-Il
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.569-574
    • /
    • 2001
  • The crystal structure, surface morphology and preferred orientation of the copper electrodeposit were investigated by the using sulfate bath with $SiO_2$suspensions and the cathode substrate Au sputtered. As by the addition of colloidal silica in copper electrolytic bath and Au pre-coating on substrate, the crystal particles of deposits was fined-down, made uniform and the account of particles were increased. Hardness of copper electrodeposits with colloidal silica increased about 15% in comparison with that of pure copper deposit film and (111), (200) and (311) plane of X-ray diffraction patterns were almost swept away, so preferred orientation of the copper deposits changed from (111) to (110) plane by codeposit $SiO_2$ and precoating the substrate.

  • PDF

Effect of Metals on Tobacco Mosaic Virus Infection (담배모자이크 바이러스 감염성에 대한 금속의 영향)

  • Choi, C.W
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.23-26
    • /
    • 1998
  • The efficacy of various concentration of divalent copper and zinc ions was evaluated separately for the infectivity of tobacco mosaic virus. Infectivity of TMV was more enhanced by addition of zinc, while it was decreased by addition of copper. The number of local lesions were more produced on tobacco leaves inoculated with inoculum sap containing zinc than those inoculated with sap only. The effect of copper inhibited the infectivity of TMV is dependent on copper concentration. TMV particles treated with various concentration of zinc and copper, respectively, analyzed by electrophoresis, and appeared to be altered in electrophoretic behavior. When TMV was exposed to zinc concentration at more than 200mM, the viral particles were completely degraded, and at 40-20 mM they were barely detectable, but at 2 mM they were quite stable. When TMV was exposed at less than concentration of 20 mM of copper were degraded.

  • PDF

Effect of the compacting additives on the Discharge Characteristics of the Negative Electrode for Ni-MH Battery (니켈-수소저장합금전지 음극의 방전특성에 미치는 성형첨가제의 영향)

  • Jung, Jae-Han;Lee, Han-Ho;Kim, Dong-Myung;Lee, Kee-Young;Lee, Jai-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.65-73
    • /
    • 1995
  • Negative electrode was prepared by mixing $Ti_{0.7}Zr_{0.3}Cr_{0.3}Mn_{0.3}V_{0.6}Ni_{0.8}$ alloy powder with copper or nickel powder and pressing in the air. The cycled electrodes were analyzed with SEM, potentiostat and electrochemical impedance spectroscopy. It was found that the Cu-compacted electrode showed better low temperature dischargeability and higher rate capability than Ni-compacted electrode. From SEM analysis of the cycled electrode compacted with copper powder, it was observed that the surface of MH particles was covered with copper grains and whisker precipitated from electrolyte after dissolution during cell test. It is found that the improved electrode characteristics are attributed to the copper layer on MH particles deposited by dissolution and precipitation(DP) process.

  • PDF

Preparation of Cu-Ag Powder having Core-Shell Structure by Electroless Plating Method (무전해 도금법을 이용한 코어 셸 구조의 Cu-Ag분말 제조)

  • Kim, Jong-Wan;Lee, Huk-Hee;Won, Chang-Whan
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.1
    • /
    • pp.47-52
    • /
    • 2009
  • Cu-Ag powder having Core-Shell structure was prepared from by electroless plating method using agents such as $AgNO_3$, $NH_{4}OH$, Hydroquinone. Ag coated copper powders were analyzed using scanning electron microscopy(SEM) and energy dispersive X-ray spectrometer(EDX). The silver coating layer of copper powder was affected from various reaction conditions such as molar ratio of $NH_{4}OH$, $AgNO_3$, and pulp density. Free silver was generated below 0.1M or 0.3M and above of $NH_{4}OH$ mole ratio. Silver coating layer thickened as addition of $AgNO_3$. When the pulp density reached 12% with 0.2M $NH_{4}OH$, and 0.15M $AgNO_3$ at $4^{\circ}C$, silver was homogeneously distributed around the copper particles and free silver particles were not generated.

Effect of Added Supercritical CO2 on the Characteristics of Copper Electroless Plating on PET Film Substrate (PET 필름기재의 구리 무전해도금에 있어서 초임계 CO2 유체가 도금 특성에 미치는 영향)

  • Lee, Hee-Dai;Kim, Moon-Sun;Kim, Chul kyung
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.384-390
    • /
    • 2007
  • In this study, electroless plating of copper was performed on PET film by using the blend of supercritical $CO_2$ and plating solution. The optimum volumetric ratio of supercritical fluid and plating solution was found to be 1:9 and dispersion property was poor at $CO_2$ vol% langer than 10%. Electroless plating of copper was best at $25^{\circ}C$ and 15 MPa. Role of added supercritical $CO_2$ is not to increase solubility but to disperse and maintain Cu-particles as the 1st particles.

Surface Modification of Silica Spheres for Copper Removal

  • Kim, Byoung-Ju;Park, Eun-Hye;Kang, Kwang-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.5
    • /
    • pp.317-320
    • /
    • 2016
  • Efficient copper removal from water was achieved by using surface modified silica spheres with 3-mercaptopropyltrimethoxysilane (MPTMS) using base catalyst. The surface modification of silica spheres was performed by hydrolysis and condensation reactions of the MPTMS. The characteristic infrared absorption peaks at 2929, 1454, and 1343 cm−1 represent the −CH2 stretching vibration, asymmetric deformation, and deformation, respectively. The absorption peaks at 2580 and 693 cm−1 corresponding the −SH stretching vibration and the C-S stretching vibration indicate the incorporation of MPTMS to the surface of silica spheres. Field emission scanning electron microscope (FESEM) image of the surface modified silica sphere (SMSS) shows nano-particles of MPTMS on the surface of silica spheres. High concentration of copper solution (1000 ppm) was used to test the copper removal efficiency and uptake capacity. The FESEM image of SMSS treated with the copper solution shows large number of copper lumps on the surface of SMSS. The copper concentration drastically decreased with increasing the amount of SMSS. The residual copper concentrations were analyzed using inductively coupled plasma mass spectrometer. The copper removal efficiency and uptake capacity with 1000 ppm of copper solution were 99.99 % and 125 mg/g, respectively.

A STUDY ON THE FRACTURE OF DENTAL AMALGAM (치과용 아말감의 파절에 관한 연구)

  • Huh, Hyeon-Do;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.9 no.1
    • /
    • pp.101-106
    • /
    • 1983
  • It was the purpose of this study to investigate the fracture mode of dental amalgam by observing the crack propagation, and to relate this to the microstructure of the amalgam. Caulk 20th Century Regular, Caulk Spherical, Dispersalloy, and Tytin amalgam alloys were used for this study. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (Capmaster, S.S. White), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12 mm in height and was pressed by the Instron Universal Testing Machine at the speed of 1mm/min with 120Kg. The specimen removed from the mold was stored in the room temperature for a week. This specimen was polished with the emery papers from #100 to #200 and finally on the polishing cloth with 0.06${\mu}Al_2O_3$ powder suspended in water. The specimen was placed on the Instron testing machine in the method similar to the diametral tensile test and loaded at the crosshead speed of 0.05mm/min. The load was stopped short of fracture. The cracks on the polished surface of specimen was examined with scanning electron microscope (JSM-35) and analyzed by EPMA (Electron probe microanalyzer). The following results were obtained. 1. In low copper lathe-cut amalgam, the crack went through the voids and ${\gamma}_2$ phase, through the ${\gamma}_1$ phase around the ${\gamma}$ particles. 2. In low copper spherical amalgam, it was observed that the crack passed through the ${\gamma}_2$ and ${\gamma}_1$ phase, and through the boundary between the ${\gamma}_1$ and ${\gamma}$ phase. 3. In high copper dispersant (Dispersalloy) amalgam, the crack was found to propagate at the interface between the ${\gamma}_1$ matrix and reaction ring around the dispersant (Ag-Cu) particles, and to pass through the Ag-Sn particles. 4. In high copper single composition (Tytin) amalgam, the crack went through the ${\gamma}_1$ matrix between ${\eta}$ crystals, and through the unreacted alloy particle (core).

  • PDF

Nanodispersion-Strengthened Metallic Materials

  • Weissgaerber, Thomas;Sauer, Christa;Kieback, Bernd
    • Journal of Powder Materials
    • /
    • v.9 no.6
    • /
    • pp.441-448
    • /
    • 2002
  • Dispersions of non-soluble ceramic particles in a metallic matrix can enhance the strength and heat resistance of materials. With the advent of mechanical alloying it became possible to put the theoretical concept into practice by incorporating very fine particles in a flirty uniform distribution into often oxidation- and corrosion- resistant metal matrices. e.g. superalloys. The present paper will give an overview about the mechanical alloying technique as a dry, high energy ball milling process for producing composite metal powders with a fine controlled microstructure. The common way is milling of a mixture of metallic and nonmetallic powders (e.g. oxides. carbides, nitrides, borides) in a high energy ball mill. The heavy mechanical deformation during milling causes also fracture of the ceramic particles to be distributed homogeneously by further milling. The mechanisms of the process are described. To obtain a homogeneous distribution of nano-sized dispersoids in a more ductile matrix (e.g. aluminium-or copper based alloys) a reaction milling is suitable. Dispersoid can be formed in a solid state reaction by introducing materials that react with the matrix either during milling or during a subsequent heat treatment. The pre-conditions for obtaining high quality materials, which require a homogeneous distribution of small dis-persoids, are: milling behaviour of the ductile phase (Al, Cu) will be improved by the additives (e.g. graphite), homogeneous introduction of the additives into the granules is possible and the additive reacts with the matrix or an alloying element to form hard particles that are inert with respect to the matrix also at elevated temperatures. The mechanism of the in-situ formation of dispersoids is described using copper-based alloys as an example. A comparison between the in-situ formation of dispersoids (TiC) in the copper matrix and the milling of Cu-TiC mixtures is given with respect to the microstructure and properties, obtained.

Hydrothermal Synthesis of Rod-like Copper Oxide Crystals

  • Pee, Jae-Hwan;Lee, Dong-Wook;Kim, Ung-Soo;Choi, Eui-Seok
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.167-168
    • /
    • 2006
  • A hyrdrothermal synthesis has been developd to prepare rod-like crystals of copper oxide using copper nitrate trihydrate as a function of synthesis temperature, stirring speed and solution pH value. The properties of the fabricated crystals were studied using scanning electron microscopy, X-ray diffraction and particle size analysis. The morphology of the synthesized CuO was dependent on both the pH value of the solution and the morphology of the seed materials. Synthesized particles have regular morphologies and a uniform size distribution.

  • PDF

Study on Heat Transfer Characteristics according to Flowing Particles in a Cold Water Tube

  • Park, Ki-Won;Kim, Myoung-Jun;Jung, Sung-Chan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.243-251
    • /
    • 2007
  • This experiment was conducted to investigate the effect of particles on the heat transfer characteristics of fluids flowing in a cold water tube. Plastic beads with 3 different sizes were used as flowing particles with cold water. An experimental test section was composed of concentric double tubes having diameters of 25mm for the inner tube and 50mm for the outer tube. The materials for the inner and outer tubes are copper and PVC respectively. It was found that the particles enhanced the heat transfer coefficient by random and vortex motion in the fluid. Hence the heat transfer coefficients for the fluid with 2mm, 5mm and $2{\times}6mm$ particles were $7%{\sim}37%$ higher than the fluid without the particles.