• Title/Summary/Keyword: conventional point monitoring

Search Result 67, Processing Time 0.027 seconds

A Study on the Corrosion Inhibition Effects of Sodium Heptanoate for Carbon Steel in Aqueous Solution

  • Won, D.S.;Kho, Y.T.
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.227-232
    • /
    • 2004
  • The carboxylates as a corrosion inhibitor has been studied by many researchers because of its environmental safety and low depletion rate. However, conventional test methods of inhibitor such as weight loss measurements, linear polarization resistance and corrosion potential monitoring etc., evaluate uniform corrosion of metals. These methods are unable to evaluate crevice-related corrosions, which are encountered in most of heat exchanging facilities. In order to choose the optimum corrosion inhibitor, the appropriate test methods are required to evaluate their performances in service environment. From this point of view, polarization technique was used to evaluate the characteristics of sodium heptanoate on corrosion behavior for carbon steel. Especially a thin film crevice sensor technique were applied to simulate the crevice corrosion in this study. From these experiments, we found that oxygen as an oxidizing agent was required to obtain stable passive film on the metal. Presence of oxygen, however, accelerated crevice corrosion. Potential shift by oxygen depletion and weakened inhibitive film inside the crevice were responsible for such accelerated feature. It is shown that film for corrosion inhibition is a mixture of sodium heptanoate and iron (II) heptanoate as reaction product of iron surface and sodium heptanoate. The iron (II) heptanoate which has been synthesized by reaction of heptanoic acid and ferrous chloride in methanol solution forms bidentate complex.

The development of radiation lifetime measuring module for KAEROT/m2 (KAEROT/m2용 방사선 수명 측정모듈 개발)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

Simulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications

  • Gandha Satria Adi;Dong-Seok Kim;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.568-574
    • /
    • 2024
  • The development of radiation-tolerant radio-frequency (RF) systems can be a solution for applications in extreme radiation environments, such as nuclear power plant monitoring and space exploration. Among the crucial components within an RF system, the low noise amplifier (LNA) stands out due to its vulnerability to TID effects, mainly relying on transistors as its main devices. In this study, the TID effects in the LNA using standard 0.18 ㎛ complementary metal oxide semiconductors (CMOS) technology are estimated and analyzed. The results show that the LNA can withstand absorbed radiation up to 100 kGy. The S21, S11, noise figure (NF), stability (K), and linearity of the third input intercept point (IIP3) slightly shifted from the initial values of 0.8312 dB, 0.793 dB, 0.00381 dB, 1.34406, and 2.36066 dBm, respectively which are still comparable to the typical performances. Moreover, the standard 0.18 ㎛ technology has demonstrated its radiation tolerance, as it exhibits negligible performance degradation in the conventional LNA even when exposed to radiation levels up to 100 kGy. In this context, simulation approach offers a means to predict the TID effects and estimate the radiation exposure limit for electronic devices, particularly when transistors are used as the primary RF components.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

A Study on the Implementation of USN Technologies for Safety Management Monitoring of Architectural Construction Sites (건축공사현장의 안전관리 모니터링을 위한 USN 기술 적용에 관한 연구)

  • Kim, Kyoon-Tai
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.103-109
    • /
    • 2009
  • The construction industry has the highest death rate related to safety accidents of any industry. Furthermore, in contrast to other industries, where the death rate related to safety accidents has been steadily declining, both the death toll and the number of accidents in the construction industry have been on the rise. Construction accidents occur when various risks increase in an intertwined way to reach a tipping point; a moment when such factors cannot be tolerated any longer Conventional safety management methods have restrictions in terms of their ability to fully prevent all types of safety accidents. This research considers ways in which USN technology can be applied to safety management on a construction site, and derives a method of applying USN technology for safety management monitoring. The tasks related to safety management on construction sites, as well as the occurrence of accidents, are first analyzed. By analyzing the characteristics of construction accidents, the factors that must be a priority and the factors that can be a lower priority are derived. Finally, the configuration of a monitoring system for safety management on a construction site to which USN technology is applied is presented. It is expected that safety accidents can be prevented from occurring on construction sites by applying this cutting-edge USN technology.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

A Scheme on Internet-based Checking for Variant CNC Machines in Machine Shop

  • Kim, Dong-Hoon;Kim, Sun-Ho;Koh, Kwang-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1732-1737
    • /
    • 2004
  • This paper proposes Internet-based checking technique for machine-tools with variant CNC (Computerized Numerical Controller). According to the architecture of CNC, CNC is classified into two types such as CAC (Closed Architecture Controller) which is conventional CNC, and OAC (Open Architecture Controller) which is a recently introduced PC-based controller. CAC has a closed architecture and it is dependent on CNC vender specification. Because of this, it has been very difficult for users to implement an application programs in CNC domain. Therefore, an additionally special module is required for Internet-based application such as remote checking. In this case, web I/O embedded module can be efficiently applied for Internet-based checking. The module is directly attached to TCP/IP network for communication. In order to obtain the monitoring data of CNC machines, the I/O signals of the module are assigned to PLC (Programmable Logic Controller) input and output (I/O) signals within CNC domain. On the other hand, OAC has a PC-based open architecture and an additional module is not necessary for the connection with external site. Because of this, a simple DAU is just used for signal sensing and data acquisition without additional communication modules. For Internet-based remote checking of machine-tools with OAC, a user-defined daemon and application programs are implemented as the form of internal function within the PC-based controller. Internet communication is performed between the daemon program in CNC domain and web script programs in external server. Checking points defined in this research are classified into two categories such as structured point and operational point. The formal includes the vibration of bearing, temperature of spindle unit and another periodical management. And the latter includes oil checking, clamp locking/unlocking and machining on/off status.

  • PDF

Multi-Point Optical Fiber Grating Strain Sensor System (광섬유 격자 다중화 스트레인 센서 시스템)

  • Lee, Yong-Wook;Jung, Jae-Hoon;Chung, Seung-Hwan;Lee, Byoung-Ho;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2001
  • An optical fiber sensor is capable of nondestructive measurement of a structure and it has an advantage of the immunity to electromagnetic interference because light is not affected by electromagnetic wave. In addition, if optical fibers are buried in an object like a concrete, this sensor tan analyze defects and physical status of the object without disassembling it. Especially, the fiber Bragg grating sensor is a promising optical fiber sensor capable of nondestructive test of such an object. A fiber Bragg grating has the characteristics of reflecting or blotting light of a specific wavelength. If we apply physical quantity like strain to the fiber Bragg grating, the center wavelength of the reflected light is shifted and then we can find the physical quantity applied to the fiber Bragg grating by measuring the center wavelength shift of the reflected light. The fiber Bragg grating sensor capable ot static and dynamic strain measurement is being used in health-monitoring of buildings, structures, etc. Recently increasing is interest in dynamic strain measurement inevitable to the civil structures such as roads and bridges. In this study we implemented the optical fiber sensor system which can measure dynamic strain at multiple points using Fabry-Perot wavelength demodulation. And we measured the static and dynamic strain using this sensor system with a test structure(cantilever). Measurement results were similar to those obtained with the conventional electrical measurement methods.

  • PDF

Runoff Characteristics of Stormwater in Small City Urban Area (국내 중소 도시지역 강우유출수의 유출특성)

  • Lee, Hong-Shin;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.193-202
    • /
    • 2009
  • This study was conducted to identify the magnitude of first flush in small city urban area and to provide the basic information on the criteria of stormwater runoff management. Monitoring site was surrounded by residential area in Gumi city near to national industrial complex and the monitoring period was three months. Total watershed area was 24.9 ha, where 80% of the area is impervious (asphalt of pavement type). Periodic monitoring of conventional water quality parameters were conducted with six times of rainfall period. Event mean and site mean concentrations for all the parameters were calculated based on the analytical results. Particle size distribution was 9.82 ${\mu}m$ for $D_{0.1}$, 38.99 ${\mu}m$ for $D_{0.5}$ and 159.61 ${\mu}m$ for $D_{0.9}$ respectively. First flush phenomenon was detected highly in particulate solids than dissolved ones. The first flush criteria results by mass first flush contained between 44.4% to 58.5% pollutant mass during the first 30% of runoff volume. Mass first flush ratio and particle size distribution obtained in this study are expected to provide the basic information for the design and operation of non-point source treatment facility.

Real-time monitoring for blending uniformity of trimebutine CR tablets using near-infrared and Raman spectroscopy (근적외분광분석법과 라만분광분석법을 이용한 트리메부틴말레인산 서방정의 혼합 과정 모니터링)

  • Woo, Young-Ah
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.519-526
    • /
    • 2011
  • Chemometrics using near-infrared (NIR) and Raman spectroscopy have found significant uses in a variety quantitative and qualitative analyses of pharmaceutical products in complex matrixes. Most of the pharmaceutical can be measured directly with little or no sample preparation using these spectroscopic methods. During pharmaceutical manufacturing process, analytical techniques with no or less sample preparation are very critical to confirm the quality. This study showed NIR and Raman spectroscopy with principal component analysis (PCA) was very effective for the blending processing control. It is of utmost importance to evaluate critical parameters related to quality of products during pharmaceutical processing. The blending is confirmed by off-line determination of active pharmaceutical ingredient (API) by a conventional method such as high performance liquid chromatography (HPLC) and UV spectroscopy. These analytical methods are time-consuming and ineffective for real time control. This study showed the possibility for the determination of blend uniformity end-point of CR tablets with the use of both NIR and Raman spectroscopy. The samples were acquired from six positions during blending processing with U-type blender from 0 to 30 min. Using both collected NIR and Raman spectral data, principal component analysis (PCA) was used to follow the uniformity of blending and finally determine the end-point. The variation of homogeneity of six samples during blending was clearly found and blend uniformity end-point was successfully confirmed in the domains of principal component (PC) scores.