• Title/Summary/Keyword: conventional medicine

Search Result 2,802, Processing Time 0.025 seconds

Diameters of the Thoracic Aorta Measured with Multidetector Computed Tomography (다중검출 전산화 단층촬영을 이용하여 측정한 흉부대동맥의 직경)

  • Lee, Gun;Lim, Chang-Young;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • Background: Background: Computed tomography (CT) is the main tool for detecting abnormalities of the thoracic aorta, but conventional CT only shows the cross-sectional images. These CT images have some limitations fo accuratly measuring the thoracic aortic diameters at various levels. Multidetector computed tomography (MDCT) overcomes these limitations. We measured the thoracic aortic diameter perpendicular to the loop-shaped thoracic aortic course and this was studied in relation to age, gender, height, weight, the body surface area, the body mass index and the presence of hypertension. Material and Method: Thirty hundred thirty one patients (males: 141 patients and females: 190 patients) who had no abnormalities of the thoracic aorta were investigated using MDCT aortography. They were divided into three age categories: 20~39 years old, 40~59 years old and over age 60. The image was reformed with multiplanar reconstruction and the diameter of the aorta was measured perpendicular to the aortic course at 5 anatomic segments. Level A was the mid-ascending aorta, level B was the distal ascending aorta, level C was the aortic arch, level D was the aortic isthmus and level E was the mid-descending aorta. Result: The mean age was 49.5 years old for males and 54.9 years old for females (p<0.05). The mean diameter of the thoracic aorta at level A was 31.1 mm, that at level B was 30.2 mm, that at level C was 26.5 mm, that at level D was 24.0 mm and that at level E was 22.6 mm. The diameters at all the levels were gradually increased with age. Hypertensive patients had larger diameters than did the non-hypertensive population. There was a positive correlation between the ascending aortic diameter (levels A&B) and height and the body surface area, but there were no statistical differences at the aortic arch (level C) and the descending aorta (levels D&E). There were no statistical differences of the weight and body mass index at all levels. Conclusion: The diameters of the thoracic aortas were directly correlated with gender, age and hypertension. Height and the body surface area were only correlated with the ascending aorta. Weight and the body mass index have no statistical difference at all levels. We measured the age related thoracic aortic diameters and the upper normal limits and we provide this data as reference values for the thoracic aortic diameter in the Korean population.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

The Results of Radiation Therapy in Locally Advanced Non-Small Cell Lung Cancer (국소적으로 진행된 비소세포폐암의 방사선치료 성적)

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Joon;Kim Jae Young;Shim Jae Won;Lee Choon Taek;Kang Yoon Koo;Kim Tae You
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.233-241
    • /
    • 1997
  • Purpose : This study was done to evaluate the survival rate and Prognostic factors of patients with inoperable non-small cell lung cancer(NSCLC) treated with radiation therapy. Materials and Methods A retrospective analysis was undertaken of 62 Patients who had inoperable NSCLC treated with radiation therapy from January 1991 through December 1993. According to AJCC slaging, stage IIIA was 14 patients and stage IIIB was 48 patients. Forty Gy to 70.2Gy to the primary tumor site was delivered with daily fractions of 1.8Gy or 2Gy, 5days per week. Thirty-seven patients received neoadjuvant chemotherapy. Results : Complete, partial and no response to radiation therapy were 3 patients, 34 Patients and 25 patients, respectively The median survival period of all patients was 11 month. One rear survival rate, 2 year survival rateand 5 rear survival rate for all patients were 45.0%, 14.3%, and 6.0% respectively The median survival period was 6.5 months in stage IIIA and 13 months in stage IIIB. One year survival rates were 28.6% in stage IIIA and 50.3% in stage IIIB In univariaite analysis, prognostic factors affecting survival were T-s1aging, AJCC staging, and response after radiation therapy (P<0.05) . Pretreatment peformance status affected survival but was not statistically significant (0.050.1). In multivariate analysis, Pathology and response to radiation therapy are independently significant prognostic factor. T stage was marginally significant (P=0.0809). During follow-up duration, distant metastasis developed in 20 patients-bone metastasis in 10 patients, brain metastasis in 3 patients, liver mentastasis in 3 patients, contralateral lung metastasis in 1 patients and multiple metastases in 3 patients. Conclusion : Conventional radiotherapy alone or combined chemoradiotherapy are unlikely to achieve long term survival in patients with NSCLC. Surgery after concurrent chemoradiotherapy is Ivied to improve the local control in our hospital

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Clinical Characteristics in Patients with Kawasaki Disease Who Received Intravenous Gamma-globulin Retreatment (가와사끼병에서 감마글로불린 재투여가 필요했던 경우의 임상적 특징)

  • Kim, Deok-Soo;Hahn, Yoon-Soo;Han, Heon-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1411-1416
    • /
    • 2002
  • Purpose : Although the use of intravenous gamma-globulin(IVGG) in Kawasaki disease(KD) is effective in reducing clinical symptoms and coronary artery complications, 20-30% of patients have persistent or recrudescent fever and ongoing clinical symptoms. In these patients, the additional infusion of IVGG is considered. The authors studied the characteristics of patients who received IVGG retreatment, and compared them with the patients who did not need IVGG retreatment, for determination of IVGG retreatment. Methods : We reviewed the medical records of 117 KD patients who could be followed up at least six months. We studied the conventional laboratory findings, electrocardiogram(EKG), signal averaged ECG(SAECG) and echocardiogram. Results : Twenty three patients had early cardiac complications during the six months of follow-up. Four patients had late cardiac complications after six months. The early cardiac complication rate was higher in the IVGG retreatment group than the single infusion group(P<0.0001). The late complication rate was also higher in the retreatment group(P<0.0001). The patients who received methyl-prednisolone(m-PD) pulse therapy had much higher rates of early and late cardiac complications than those who received a single IVGG infusion. Among the clinical data and laboratory findings, only CRP increased significantly in patients who have had the cardiac complications. The IVGG retreatment group had increased CRP than the single infusion group. Conclusion : The patients with increased initial CRP may have an increased incidence of complications and an increased possibility of IVGG retreatment. We thought that retreated KD patients might have inflammations severe enough to need high dose IVGG as shown by high CRP levels, and IVGG retreatment could not prevent coronary artery lesions sufficiently.

The Analysis of Predictive Factors for the Identification of Patients Who Could Benefit from Respiratory-Gated Radiotherapy in Non-Small Cell Lung Cancer (비소세포성 폐암에서 호흡동기방사선치료 적용 환자군의 선택을 위한 예측인자들의 분석)

  • Jang, Seong-Soon;Park, Ji-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.228-239
    • /
    • 2009
  • Purpose: 4DCT scans performed for radiotherapy were retrospectively analyzed to assess the possible benefits of respiratory gating in non-small cell lung cancer (NSCLC) and established the predictive factors for identifying patients who could benefit from this approach. Materials and Methods: Three treatment planning was performed for 15 patients with stage I~III NSCLC using different planning target volumes (PTVs) as follows: 1) PTVroutine, derived from the addition of conventional uniform margins to gross tumor volume (GTV) of a single bin, 2) PTVall phases (patient-specific PTV), derived from the composite GTV of all 6 bins of the 4DCT, and 3) PTVgating, derived from the composite GTV of 3 consecutive bins at end-exhalation. Results: The reductions in PTV were 43.2% and 9.5%, respectively, for the PTVall phases vs. PTVroutine and PTVgating vs. PTVall phases. Compared to PTVroutine, the use of PTVall phases and PTVgating reduced the mean lung dose (MLD) by 18.1% and 21.6%, and $V_{20}$ by 18.2% and 22.0%, respectively. Significant correlations were seen between certain predictive factors selected from the tumor mobility and volume analysis, such as the 3D mobility vector, the reduction in 3D mobility and PTV with gating, and the ratio of GTV overlap between 2 extreme bins and additional reductions in both MLD and $V_{20}$ with gating. Conclusion: The additional benefits with gating compared to the use of patient-specific PTV were modest; however, there were distinct correlations and differences according to the predictive factors. Therefore, these predictive factors might be useful for identifying patients who could benefit from respiratory-gated radiotherapy.

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

The Results of Radiation Therapy in Stage III Non-Small Cell Lung Cancer (III기 비소세포성 폐암의 방사선치료 성적)

  • Choi, Sang-Gyu;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.311-319
    • /
    • 1995
  • Purpose : To evaluate the survival and prognostic factors in patients with stage III non-small cell lung cancer treated with curative radiotherapy alone or combined with chemotherapy Materials and Methods : A retrospective analysis was undertaken of 35 patients who had locally advanced non-small-cell lung cancer and treated with curative radiotherapy in Department of Therapeutic Radiology, Kangdong Sacred Heart Hospital, from January 1991 through December 1993. According to AJCC staging, 15 patients were stage IIIA, and 20 were stage IIIB. Radiotherapy was delivered with 1 8-2 Gy per fraction/day. 5 days per week using 6 MV X-ray, to a total dose ranging from 48.8 Gy to 66.6 Gy (median, 61.2 Gy) in 4 to 9 weeks. Ten patients received neoadjuvant or concurrent chemotherapy with FIP (5-FU, ifosfamide, and cisplatin) or FP (5-FU and cisplatin) Results : For all Patients, median survival was 6 months. 1-year and 2-year survival rates were 23.3% and 6.7%, respectively The median survival was 8 months in stage IIIA and 5.5 months in stage IIIB. In patients treated with radiation therapy alone, median survival was 5 months and 1-year survival rate was 9%. In patients who received chemotherapy, median survival was 11 months and 1-year survival rate was 60%. The difference of survival between these two groups was statistically significant (p=0.03). Total radiation dose, degree of response, and Post-treatment ECOG score were also significantly associated with survival. But it was not affected by age, sex, pretreatment ECOG score, presence or absence of weight loss, tumor location. pathologic type, N stage, and degree of response to treatment. Conclusion : Conventional radiotherapy alone is unlikely to achieve long term survival in patients with stage III NSCLC. Radiotherapy with altered fractionation schedule or multimodality treatment combined with surgery and/or chemotherapy should be considered if feasible.

  • PDF

Combined Transcatheter Arterial Chemoembolization and Local Radiotherapy for Unresectable Hepatocellular Carcinoma (절제불가능 원발성 간암에서 경간동맥 항암 색전술과 국소 방사선의 병용요법)

  • Seong Jinsil;Keum Ki Chang;Han Kwang Hyub;Lee Do Yun;Lee Jong Tae;Chon Chae Yoon;Moon Young Myoung;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.159-165
    • /
    • 1998
  • Purpose : The best prognosis for hepatocellular carcinoma can be achieved with surgical resection. However, the number of resected cases is limited due to the advanced lesion or associated liver disease. A trial of combined transcatheter arterial chemoembolization(TACE) and local radiotherapy(RT) for unresectable hepatocellular carcinoma(HCC) was prospectively conducted and its efficacy and toxicity were investigated. Materials and Methods : From 1992 to 1994, 30 Patients with unresectable HCC due either to advanced lesion or to associated cirrhosis were entered in the study Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two-thirds of the whole liver, and an ECOG scale of more than 3. Patient cHaracteristics were : mean tumor size $8.95\pm3.4cm$, serum AFP+ in all patients, portal vein thrombosis in all patients, liver cirrhosis in 22 patients, and UICC stage III and IVA in 10 and 20 patients, respectively. TACE was performed with the mixture of Lipiodol(5ml) and Adriamycin(50mg) and Gelfoam embolizatin. RT(mean dose $44.0\pm9.3Gy$) 10 days with conventional fractionation. Results : An objective response was observed in 19 patients($63.3\%$). Survival rates at 1 2, and 3 years were $67\%,\;33.3\%$ and $22.2\%$, respectively. Median survival was 17 months. There were 6 patients surviving more than 3 years. Distant metastasis occurred in 10 patients, with 8 in the lung only and 2 in both lung and bone, Toxicity included transient elevation of liver function test in all patients, fever in 20, thrombocytopenia in 4, and nausea and vomiting in 1. There was no treatment-related death. Conclusion : Combined TACE and RT appear to produce a favorable response and survival results with minimal toxicity.

  • PDF