• 제목/요약/키워드: contact angle value

검색결과 172건 처리시간 0.025초

접촉각 측정에 의한 표면의 특성연구( II ) -섬유나 막대의 직경이 접촉각에 미치는 영향- (Characterization of Surfaces by Contact Angle Goniometry - II . Effect of Curvature on Contact Angle -)

  • 박정희
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.437-445
    • /
    • 1991
  • The effect of diameter of rods or fibers on contact angle was studied in a vertical rod configuration. A contact angle measuring device described in the previous paper was optimized for the measurement of small-diameter fibers. It was shown that contact angles of water and hexadecane on nylon 6 monofilsments and glass rods increased with decrease of diameter below a critical diameter, which varied from one system to another. Beyond the critical value, contact angle of the liquid on the vertical glass rod reached to an equilibrium value which is equal to the unique value of the contact angle of the liquid drop on the horizontal glass plate.

  • PDF

기하학적 원리에 의거한 접촉각의 측정 (Development of a Contact Angle Measurement Method Based Upon Geometry)

  • 김동수;표나영;서승희;최우진;권영식
    • 자원리싸이클링
    • /
    • 제7권5호
    • /
    • pp.41-45
    • /
    • 1998
  • 간단한 기하학적 원리에 의해 접촉각을 계산할 수 있는 방안을 모색하였다. 접촉각 측정에 일반적으로 이용되는 기기를 사용하지 않고, 단지 고체 표면의 용액 렌즈가 형성하는 접촉원의 지름과 렌즈의 높이를 측정함으로써 상당한 신뢰성을 가진 접촉각의 크기를 계산할 수 있었다. 이 방법의 신뢰성을 확인하기 위하여 동일한 용액 렌즈에 대해 일반적인 접촉각 측정 장치로 접촉각을 측정하여 그 값들을 상호 비교한 결과 오차 한계의 범위내에서 거의 일치함을 확인하였다.

  • PDF

박판 궤도륜 볼베어링의 특성해석 및 피로수명 평가 (Analysis and Fatigue Life Evaluation of the Ball Bearing with Thin-Section Raceways)

  • 김완두
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.48-55
    • /
    • 1997
  • The ball bearing with thin-section raceways which is much lighter than other conventional bearings used in most modem passenger cars and small tracks. The important design parameters of this bearing is the groove radius of raceways, the diametral clearance, the free contact angle and so on. The optimal value of these parameters were determined by considering the dynamic load capacity, the contact angle and the calculated fatigue life. The contact angle between a ball and raceways was calculated by considering the local contact deformation and the structural deformation of thin-section raceways which was estimated by FEM. The raceways were made by means of the press-forming process. The fatigue life tester was designed and manufactured. The fatigue life test was executed and the reliability of this bearing was confirmed.

인공산성우와 토양시비가 소나무잎의 광합성속도, 왁스 함량 및 접촉각에 미치는 영향 (Effects of Simulated Acid Rain and Soil Fertilizers on Photosynthetic Rate, wax Content, and Contact Angle of Japanese Red Pine(Pinus densiflora Sieb. et Zucc.) Leaves)

  • 최기영;이용범;채의석;이경재
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.263-268
    • /
    • 1996
  • This study was conducted for the assessment of the effects of acid rain and soil fertilizers on photosynthetic rate, was content, and contact angle on 5-year seedlings of Japanese red pine (Pinus densiflora Sieb. et Zucc.) leaves. The seedlings were exposed to pH 3.0 (simulated acid rain), pH 6.5 (groung water) and rain (pH around 4.6). The seedlings were also treated with $Ca(OH)_2, Mg(OH)_2, and Ca(OH)_2 + Mg(OH)_2 + C.F.(compound fertilizer)$. Photosynthetic rate, stomatal conductance, was content, contact angle value, and mineral nutrient content of the leaves were measured and the results were as follows: 1. Photosynthetic rate and stomatal conductance of the leaves increased with the increase of pH. Photosynthetic rate and stomatal conductance increased with application of soil fertilizer in the pH 3.0 treatment, but showed no changes in the rain and the pH 6.5. 2. Contact angle value and was content of the leaves did not change with the pH treatment, but increased with the fertilizer treatments. 3. Mineral nutrient contents of the leaves were lowest in the rain treatment and highest in the pH 6.5 treatment. The increase of mineral nutrient contents was observed with the soil fertilizer treatments.

  • PDF

두개하악장애환자의 전치부접촉과 측모두부형태간의 관계에 관한 연구 (A Study on the Correlation between Anterior Tooth Contacts and Cephalometric Profile in Patients with Craniomandibular Disorders)

  • Byung-Wook Kim;Kyung-Soo Han;Min Shin
    • Journal of Oral Medicine and Pain
    • /
    • 제17권2호
    • /
    • pp.37-49
    • /
    • 1992
  • 80 patients who presented at Wonkwang University Dental Hospital with craniomandibular disorders were collected for this study. To observe the occlusal contact pattern such as contact numbers, contact force and presence or absence of anterior occlusal contact, the author used T-Scan system (Tekscan, Inc, U.S.A.) with are computerized occlusal analysing system. And to study the correlation between craniofacial profile and occlusal contact pattern, cephalogram were also taken, The cephalometric items related to growth pattern, jaw bone relation and denture pattern were measured and analysed according to routine method by computerized program. The obtained data were statistically processed with SPSS/PC+ package about anterior contact pattern and its craniofacial relationship. The obtained results were as follows : 1. In terms of growth pattern, patients without anterior tooth contacts showed a tendency to downward growth of craniofacial profile. The value in this subjects were significantly different from the value of patients with anterior tooth contacts in items of low gonial angle, Jarabak ratio, SN to GoMe angle, FMA, occlusal plane to mandibular plane angle and ramus height. 2. In terms of jaw bone relationship, patients without anterior tooth contacts showed a tendency to backward growth of craniofacial profile. The value of this patients were significantly different from the value of patients with anterior tooth contacts in items of SNB, ANB, mandibular plane to anterior cranial base ratio, SNPo, NAPo and APDI items. 3. But in denture pattern, no statistically significant difference by the presence or absence of anterior tooth contacts were showed between this patients groups. 4. From this study, it could be proposed that anterior open bite in the patients with craniomandibular disorders would be originated from not dental discrepancy but skeletal discrepancy.

  • PDF

4불화탄소 플라즈마처리에 의한 폴리에스테르 직물의 발수가공 (Water Repellent Finish of Polyester Fabric Using Carbontetrafluoride Plasma Treatment)

  • 모상영;이용운;김태년;천태일
    • 한국염색가공학회지
    • /
    • 제6권3호
    • /
    • pp.27-36
    • /
    • 1994
  • In order to produce a water repellent surface on polyester fabric, samples were treated in the atmosphere of $CF_4$ glow discharge plasma. The samples used in the study were ployester fabric and poyester film. The purpose of film treatment is for the comparison of hydrophobicity with fabric sample at same treatment condition. Radio frequency(13.56MHz) generator was used as electric source and its in put power is 100 Watt. Water repellency was evaluated by contact angle measurement. Result obtained are as follows. 1) Fiber interstice of original fabric was ana lysed as 0.43$\mu$m, and this value was sufficiently ideal for making water repellent fabric. 2) The most favorable setting position of substrate was the center area between two electrodes. 3) Fabric contact angle was higher than film contact angle at same treatment condition, and its difference was more than 50${\circ}$. And it was incapalbe of fabric contact angle measurement when the film contact angle was less than 90${\circ}$. because the fabric is susceptible to absorption of water by the capillary effect. 4) Fabric contact angle can not revealed the precise defferences of surface hydrophobicity, however, the film contact angle showed the real hydrophobic nature. 5) It was not sufficient method to evaluate the hydrophobicity of fabric surface by merely measure of the water contact angle. 6) It showed high water repellent nature at 0.06 torr of $CF_4$ plasma gas pressure and duration of 45 seconds treatment, and it can not be anticipated more improved nature if the pressure and duration of treatment time were increased.

  • PDF

접촉각 측정방법을 이용한 SiC 단결정의 극성표면 판별에 있어 자연산화막의 영향 (Effect of Native Oxide Layer on the Water Contact Angle to Determine the Surface Polarity of SiC Single Crystals)

  • 박진용;김정곤;김대성;유우식;이원재
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.245-248
    • /
    • 2020
  • The wettability of silicon carbide (SiC) crystal, which has 6H-SiC and 4H-SiC regions prepared using the physical vapor transport (PVT) method, is quantitatively analyzed using dispensed deionized (DI) water droplets. Regardless of the polytypes in SiC, the average of five contact angle measurements showed a difference of about 6° between the Si-face and C-face. The contact angle on the Si-face (C-face) is measured after the removal of the native oxide using BOE (6:1), and revealed a significant decrease of the contact angle from 74.9° (68.4°) to 47.7° (49.3°) and from 75.8° (70.2°) to 51.6° (49.5°) for the 4H-SiC and 6H-SiC regions, respectively. The contact angle of the Si-face recovered over time during room temperature oxidation in air; in contrast, that of the C-face did not recover to the initial value. This study shows that the contact angle is very sensitive to SiC surface polarity, specific surface conditions, and process time. Contact angle measurements are expected to be a rapid way of determining the surface polarity and wettability of SiC crystals.

자기세정을 위한 스퍼터링 TiO2 박막의 산소 표면처리에 따른 특성 (Effects of Oxygen Surface Treatment on the Properties of TiO2 Thin Film for Self-cleaning Application)

  • 김남훈;박용섭
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.294-297
    • /
    • 2016
  • Titanium oxide ($TiO_2$) thin films were fabricated by unbalanced magnetron (UBM) sputtering. The fabricated $TiO_2$ films were treated by oxygen plasma under various RF powers. We investigated the characteristics of oxygen plasma treatment on the surface, structural, and physical properties of $TiO_2$ films prepared at various plasma treatment RF powers. UBM sputtered $TiO_2$ films exhibited higher contact angle value, smooth surface, and amorphous structure. However, the rms surface roughness $TiO_2$ films were rough, and the contact angle value was decreased with the increase of the plasma treatment RF power Also, the hardness value of $TiO_2$ film as physical properties was slightly increased with the increase of the plasma treatment RF power. In the results, the performance of $TiO_2$ films for self cleaning critically depended on the with the plasma treatment RF power.

대기압 플라즈마로 처리된 폴리프로필렌 필름의 표면 자유에너지 변화 (Surface Free Energy Change of Polypropylene Film treated by Atmospheric Pressure Plasma)

  • 권오준;탕쉰;루나;최호석
    • 접착 및 계면
    • /
    • 제4권4호
    • /
    • pp.1-6
    • /
    • 2003
  • 대기압 플라즈마를 이용하여 폴리프로필렌 필름의 표면을 처리한 후 각각 극성 용매(water)와 비극성 용매(diiodomethane)를 사용한 접촉각 측정기로 필름 표면의 접촉각을 측정하였다. 측정된 접촉각을 이용해 표면 자유에너지 변화를 계산한 후 대기압 플라즈마 처리 전후의 폴리프로필렌 필름의 접촉각과 표면 자유에너지 상태를 비교, 분석하였다. 또한 대기압 플라즈마의 처리 조건을 바꿔가며 폴리프로필렌 필름 표면을 처리함으로써 접촉각과 표면 자유에너지가 각각의 처리 조건에 따라 어떠한 영향을 받는지 연구하였다. 대기압 플라즈마 처리 조건에 따라 접촉각 및 표면 자유에너지는 최적값을 보여주거나 일정한 값에 도달하는 경향을 보여 주었다.

  • PDF

교모면적과 교합접촉양태 간의 관계에 대한 연구 (A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제19권2호
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF