• Title/Summary/Keyword: constant current stress

Search Result 145, Processing Time 0.024 seconds

Properties of the oxynitride films formed by thermal reoxidation in $N_2{O}$ gas ($N_2{O}$가스로 재산화시킨 oxynitride막의 특성)

  • 김태형;김창일;최동진;장의구
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1994
  • Properties of oxynitride films reoxidized by $N_2{O}$ gas after thermal oxidation and $N_2{O}$ oxide films directly oxidized by using $N_2{O}$ gas on the bare silicon wafer have been studied. From the AES analysis, nitrogen pile-up at the interface of Si/oxynitride and Si/$N_2{O}$ oxide has observed. $N_2{O}$ oxide and oxynitride films have the self-limited characteristics. Therefore, it will be possible to obtain ultra-thin films. Nitrogen pile-up at the interfaces of Si/oxynitride and Si/$N_2{O}$ oxide strengthens film structure and improves dielectric reliability. Although fixed charge densities and interface trap densities of N20 oxide and oxynitride films have somewhat higher than those of thermal $SiO_2{O}$, $N_2{O}$ oxide and oxynitride films showed improved I-V characteristics and constant current stress.

  • PDF

Effect of Stress on the Polarization Characteristic of Al-brass (Al-황동의 분극특성에 미치는 응력의 영향)

  • Lim, Uh-Joh;Jeong, Hae-Kyoo;Sim, Kyong-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.1-5
    • /
    • 2004
  • Al-brass is the raw material of mnufacturing tubes for heat exchanger of vessel where seawater is used to coolant because it has high level of heat coductivity and excellent mechanical properties and high level of corrosion resistance due to cuprous oxide($Cu_2O$) layer against seawater. However, damage of Al-brass tubes for heat exchanger of vessel is reported that local corrosion such as stress corrosion cracking occurred by synergism effect between mechanical factor and corrosion environment. In this study, to investigate on the effect of stress on the polarization characteristics of Al-brass. At the stress of 0% and 95% yield strength by constant displacement tester, in 3.5% NaCl + 0.1% $NH_4OH$ solution, the polarization tests were carried out. And thus open circuit potential, corrosion current density, anodic polarization, cyclic polarization and dezincification behavior of Al-brass are investigated.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

Bed Load Transport by Waves and Current (파와 해류에 의한 소류사 이동)

  • 유동훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.3
    • /
    • pp.257-264
    • /
    • 1995
  • Various factors are investigated on the bed load transport driven by waves and current, and proper forms of bed load transport formulas mainly used in river hydraulics are chosen for the estimation of combined flow bed load transport after considering the additional factors. The BYO Model is employed for the computation of maximum bed shear stress and mean bed shear stress of the combined flow. The friction factor of uni-directional flow is estimated by using modified Keulegan equation, and equivalent roughness height is determined by obtaining correct answer for the bed shear stress of uni-directional flow. Empirical constant in each bed load formula is determined by applying it to Bijker's laboratory data of bed load transport by waves and current and the formulas obtained are discussed on their final forms with the values of empirical constants.

  • PDF

Improvement in Mechanical Properties of Cryogenically Treated WC-5 wt% NbC Hard Materials Sintered by Pulsed Current Activated Sintering

  • Jeong Han Lee;Hyun Kuk Park;Jae Cheol Park
    • Korean Journal of Materials Research
    • /
    • v.32 no.12
    • /
    • pp.528-532
    • /
    • 2022
  • Recently, the necessity of designing and applying tool materials that perform machining of difficult-to-cut materials in a cryogenic treatment where demand is increasing. The objective of this study is to evaluate the performance of cryogenically treated WC-5 wt% NbC hard materials fabricated by a pulsed current activated sintering process. The densely consolidated specimens are cryogenically exposed to liquid nitrogen for 6, 12, and 24 h. All cryogenically treated samples exhibit compressive stress in the sintered body compared with the untreated sample. Furthermore, a change in the lattice constant leads to compressive stress in the specimens, which improves their mechanical performance. The cryogenically treated samples exhibit significant improvement in mechanical properties, with a 10.5 % increase in Vickers hardness and a 60 % decrease in the rupture strength compared with the untreated samples. However, deep cryogenic treatment of over 24 h deteriorates the mechanical properties indicating that excessive treatment causes tensile stress in the specimens. Therefore, the cryogenic treatment time should be controlled precisely to obtain mechanically enhanced hard materials.

ESL-𝚪-Z- Source Inverter

  • Pan, Lei;Sun, Hexu;Wang, Beibei;Dong, Yan;Gao, Rui
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.589-599
    • /
    • 2014
  • On the basis of the traditional ZSI (Z-source inverter), this paper presents a ESL-${\Gamma}$-ZSI, which uses a unique ${\Gamma}$-shaped impedance network and an extended SL network for boosting its output voltage in addition to their usual voltage-buck behavior. The inverter can increase the boost factor through adjusting shoot-through duty ratio and increasing the number of inductors. Capacitor voltage stress of ESL-${\Gamma}$-ZSI is a constant when 1>D>0, and ESL-${\Gamma}$-ZSI has small inductor current stress. The working principle of ESL-${\Gamma}$-ZSI and comparison with the classical ZSI and SL- ZSI are analyzed in detail. The power loss comparison between ESL-${\Gamma}$-ZSI and Cuk converter is analyzed detailedly. Simulation and experimental results are given to demonstrate the operation features of the inverter.

Characterization of Dielectric Relaxation and Reliability of High-k MIM Capacitor Under Constant Voltage Stress

  • Kwak, Ho-Young;Kwon, Sung-Kyu;Kwon, Hyuk-Min;Sung, Seung-Yong;Lim, Su;Kim, Choul-Young;Lee, Ga-Won;Lee, Hi-Deok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.543-548
    • /
    • 2014
  • In this paper, the dielectric relaxation and reliability of high capacitance density metal-insulator-metal (MIM) capacitors using $Al_2O_3-HfO_2-Al_2O_3$ and $SiO_2-HfO_2-SiO_2$ sandwiched structure under constant voltage stress (CVS) are characterized. These results indicate that although the multilayer MIM capacitor provides high capacitance density and low dissipation factor at room temperature, it induces greater dielectric relaxation level (in ppm). It is also shown that dielectric relaxation increases and leakage current decreases as functions of stress time under CVS, because of the charge trapping effect in the high-k dielectric.

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.

Suspension Properties of Silty Mud in Combined Wave-Current Flow (파-흐름의 공존장에서 실트질 점토의 정상특성)

  • 김차겸;이종섭
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.1
    • /
    • pp.26-33
    • /
    • 1992
  • Physical experiments were conducted to investigate the suspension properties of silty mud in combined wave-current flow. Suspension mass when there was opposing current was much higher than that when there was following current. It is due to the fact which strong turbulent flow in the bottom is developed in the opposing current but oscillatory flow effect decreases in the following current. Critical bed shear stress for suspension of silty mud in combined wave-current flow was deduced to be $\tau$$_{c}$~0.045 N/$m^2$. Formulas expressing the relation with initial suspension rate with bed shear stress, and the relation between the former and measured significant wave height were deduced. The relationship of initial suspension rate with bed shear stress was significantly scattered, but the relationship with measured significant wave height was reasonably good. When there is wave only, vertical diffusion coefficients of sediment were calculated from the vertical concentration gradients of suspended sediment when the concentration of suspended sediment approached to nearly equilibrium state. The diffusion coefficient increased exponentially with height from the bottom in the lower half of the flow depth but were nearly constant in the upper half of the flow depth.h.

  • PDF

A Proposal of the Compressive Stress Distribution Model of Ultra High-Strength Concrete (초고강도 콘크리트에 적합한 응력분포 모델의 제안)

  • 박훈규;윤영수;한상묵;장일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.436-441
    • /
    • 1997
  • This paper presents the compressive stress distribution model appropriate to predict the ultimate strength of structural elements using ultra high-strength concrete. From the results of this investigation, the following conclusions are drawn: 1. The constant value of strain at extreme concrete compression fiber of 0.0027 is seen to represent satisfactorily the experimental result for ultra high-strength concrete. 2. The current ACI-318 rectangular stress block parameters were found to overestimate the moment capacity of ultra high-strength concrete columns with eccentrically loaded. 3. The equivalent trapezoidal stress distribution model with new parameter $\lambda_1$ and $\lambda_2$ was developed.

  • PDF