• 제목/요약/키워드: conductivity measurement

Search Result 627, Processing Time 0.028 seconds

Measurement of the construction structure of hot-heated cement using nitrogen adsorption method (질소흡착법을 사용한 고온 가열 시멘트의 세공구조 측정)

  • Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.140-141
    • /
    • 2020
  • Concrete has a lower thermal conductivity or thermal diffusion coefficient compared to other building materials, so it is widely used as fireproof compartment material or refractory material for structures. However, in the event of thermal damage such as fire, cement curing agents and aggregates act differently, resulting in heat generation or deterioration of tissue due to dehydration, resulting in deterioration of physical properties and fire resistance. Therefore, in this study, the processing structure of cement paste is measured through nitrogen absorption method. The test specimen is a cement paste of 40% W/C and is set at 1000 ℃ under heating temperature conditions. As the temperature rose, the micro-pore mass below was reduced based on about 0.01 감소m, but the air gap above that was increased.Thus, in the range of pores measured in nitrogen adsorption, the air mass tended to decrease under high temperature conditions.

  • PDF

IN VIVO EVALUATION OF ACCURACY OF TWO ELECTRONIC APEX LOCATORS (전자근관장 측정기의 정확도에 관한 연구)

  • Kim, Hee-Jung;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.289-299
    • /
    • 1996
  • It is necessary to measure the length of a root canal in order to attain a satisfactory prognosis after root canal therapy. There are several methods for determining root canal length, such as tactile sensation by the dental practitioner, the utilization of x-ray film, and electronic root canal measurement. Among these, the electrical measurement methods, in which the impedence between the oral mucous membrane and periodontal membrane is determined, have advantages of simplicity and accuracy. During root canal treatment, the root canal contains a solution of high electrical conductivity such as pus, blood, sodium hypochlorite and so on. Recently a new electronic root canal measurement device of frequency-dependent type has been developed, which is capable of measuring the length of root canal under moist conditions. Endex and Root ZX, which are frequency-dependent type, were evaluated for accuracy of measuring root canal length in vivo by stereomicroscope. The result were as follows ; 1. 82.5% of Endex and 87.5% of Root ZX measured in the range of ${\pm}0.5$ mm from the apical foramen and both showed 57.5 % in the range of 0.1 mm to 0.5 mm. 2. Endex showed significantly higher accuracy in vital teeth than nonvital teeth(p<0.05). But in case of Root ZX, there was no significant difference between vital and nonvital teeth. 3. As a result of this study, there was no significant difference in accuracy between Endex and Root ZX, and both devices showed file passes the apical foramen in more than half of the cases, and it is thought that this must be considered clinically.

  • PDF

Development of An Integrated Information System for Dairy Cattle Breeding Management (젖소 사양관리의 통합전산화 시스템 개발)

  • Kim, Dong-Won;Heo, Eun-Young;Cho, Min-Ho;Jin, Feng-He
    • IE interfaces
    • /
    • v.17 no.4
    • /
    • pp.397-406
    • /
    • 2004
  • It is widely known that labor costs are continuously and rapidly growing in terms of the raw cost of products in Korea. The increased labor costs are degrading the competitiveness of dairy industry sector as in the other major industrial fields. Furthermore, the number of dairy farms is constantly decreasing while that of dairy cattle is increasing. Thus, mechanized and/or automated stockbreeding management systems are crucially required to support professional stockbreeding management, as well as to enhance the productivity of the sector. Hence this paper develops an IIS (Integrated Information System) for dairy cattle stockbreeding management. IIS is composed of five application modules and associated utility programs. The five modules are individual stock management, milking management, feeding management, propagation management, and disease management. The utility programs are involved in stock farm accounting, and handy unloading of individual stock data into a personal data acquisition device. Compared with existing foreign products, the developed system takes advantages of various stock body measurement data such as body weight, body temperature, milk conductivity, milking amount, and the number of walking steps. All the measured data are transmitted into a programmable logic controller that monitors and controls measurement devices. The transmitted data are finally aggregated into an integrated database located in the main personal computer. The integrated data are analyzed and reformed in the five modules of IIS, then, used for providing farmers with various farm states and information through application module scenes. Hence, IIS keeps the each module work in a systematic and compatible manner, while supervising the whole stockbreeding management system.

Development of a smart rain gauge system for continuous and accurate observations of light and heavy rainfall

  • Han, Byungjoo;Oh, Yeontaek;Nguyen, Hoang Hai;Jung, Woosung;Shin, Daeyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.334-334
    • /
    • 2022
  • Improvement of old-fashioned rain gauge systems for automatic, timely, continuous, and accurate precipitation observation is highly essential for weather/climate prediction and natural hazards early warning, since the occurrence frequency and intensity of heavy and extreme precipitation events (especially floods) are recently getting more increase and severe worldwide due to climate change. Although rain gauge accuracy of 0.1 mm is recommended by the World Meteorological Organization (WMO), the traditional rain gauges in both weighting and tipping bucket types are often unable to meet that demand due to several existing technical limitations together with higher production and maintenance costs. Therefore, we aim to introduce a newly developed and cost-effective hybrid rain gauge system at 0.1 mm accuracy that combines advantages of weighting and tipping bucket types for continuous, automatic, and accurate precipitation observation, where the errors from long-term load cells and external environmental sources (e.g., winds) can be removed via an automatic drainage system and artificial intelligence-based data quality control procedure. Our rain gauge system consists of an instrument unit for measuring precipitation, a communication unit for transmitting and receiving measured precipitation signals, and a database unit for storing, processing, and analyzing precipitation data. This newly developed rain gauge was designed according to the weather instrument criteria, where precipitation amounts filled into the tipping bucket are measured considering the receiver's diameter, the maximum measurement of precipitation, drainage time, and the conductivity marking. Moreover, it is also designed to transmit the measured precipitation data stored in the PCB through RS232, RS485, and TCP/IP, together with connecting to the data logger to enable data collection and analysis based on user needs. Preliminary results from a comparison with an existing 1.0-mm tipping bucket rain gauge indicated that our developed rain gauge has an excellent performance in continuous precipitation observation with higher measurement accuracy, more correct precipitation days observed (120 days), and a lower error of roughly 27 mm occurred during the measurement period.

  • PDF

Application of a Textile-based Inductive Sensor for the Vital Sign Monitoring

  • Gi, Sun Ok;Lee, Young Jae;Koo, Hye Ran;Khang, Seonah;Kim, Kyung-Nam;Kang, Seung-Jin;Lee, Joo Hyeon;Lee, Jeong-Whan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.364-371
    • /
    • 2015
  • In this study, we developed a feasible structure of a textile-based inductive sensor using a machine embroidery method, and applied it to a non-contact type vital sign sensing device based on the principle of magnetic-induced conductivity. The mechanical heart activity signals acquired through the inductive sensor embroidered with conductive textile on fabric were compared with the Lead II ECG signals and with respiration signals, which were simultaneously measured in every case with five subjects. The analysis result showed that the locations of the R-peak in the ECG signal were highly associated with sharp peaks in the signals obtained through the textile-based inductive sensor (r=0.9681). Based on the results, we determined the feasibility of the developed textile-based inductive sensor as a measurement device for the heart rate and respiration characteristics.

Preparation and Characterization of Functional Microcapsules Containing Suspensions of Conducting Materials (전도성 물질 서스펜션을 함유한 마이크로캡슐)

  • Ihm, DaeWoo;Kwon, Won Ho
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • Microcapsules containing the suspension of conducting materials such as carbon nanotube (CNT) or polyaniline (PANI) were prepared by in-situ polymerization of melamine and formaldehyde. Stable microcapsules were prepared and the mean diameter of the observed microcapsules was in the range of $10-20{\mu}m$. The surface morphology and chemical structure of microcapsules were investigated using optical microscope (OM), scanning electron microscope (SEM), and Fourier transform infrared spectroscopy (FT-IR). The thermal properties of samples were investigated by thermogravimetric analysis (TGA). The conductivity of ruptured microcapsule containing the suspension of CNTs or PANIs in tetrachloroethylene and Isopar-G was measured. As the amount of CNTs and PANIs in the core of microcapsules increased, the measured current increased. Conductivity measurement results suggest that poly (melamine-formaldehyde) based core-shell microcapsules could be applied to self-healing electronic materials systems, where CNTs or PANIs bridge a broken circuit upon release.

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

The Preparation Characteristic of Dimercaptan-Polyphenylenediamine Cathodes for Lithium Battery (리튬전지용 Dimercaptan-Polyphenylenediamine 정극의 제막특성)

  • Park, Soo-Gil;Lee, Ju-Seong
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.114-121
    • /
    • 1997
  • The positive active material for polymer film-battery was prepared by using polyphenlenediamine(PPD) synthesized in our lab. and 2,5-dimercapto-1,3,4-thiadiazole(DMcT) with various mixture ratio. The transference measurement of surface morphology and thermal stability of the prepared composite film was carried out by using SEM and TGA, respectively. Electrochemical property and electrical conductivity of the composite film were also measured by using cyclic voltammetry and four-probe method in dry box, respectively. The thermal stability of prepared composite film was up to $200^{\circ}C$. The electrical conductivity of the composite film increased and showed the highest value(about 3 S/cm) when doped at 0.4% $LiCIO_4$ solution. And we could confirm that DMcT was effective on reactivation of PPD through cyclic voltammogram.

  • PDF

Characteristics of Material Properties and Machining Surface in Electrical Discharge Machining of Ti2AlN and Ti2AlC Materials (Ti2AlN과 Ti2AlC 소결체의 마이크로 방전가공에서 재료물성에 따른 가공표면 특성)

  • Choi, Eui-Song;Lee, Chang-Hoon;Baek, Gyung-Rae;Kim, KwangHo;Kang, Myung Chang
    • Journal of Powder Materials
    • /
    • v.22 no.3
    • /
    • pp.163-168
    • /
    • 2015
  • Ti alloys are extensively used in high-technology application because of their strength, oxidation resistance at high temperature. However, Ti alloys tend to be classified very difficult to cut material. In this paper, The powder synthesis, spark plasma sintering (SPS), bulk material properties such as electrical conductivity and thermal conductivity are systematically examined on $Ti_2AlN$ and $Ti_2AlC$ materials having most light-weight and oxidation resistance among the MAX phases. The bulk samples mainly consisted of $Ti_2AlN$ and $Ti_2AlC$ materials with density close to theoretical value were synthesized by a SPS method. Machining characteristics such as machining time, surface quality are analyzed with measurement of voltage and current waveform according to machining condition of micro-electrical discharge machining with micro-channel shape.

Ordering of manganese spins in photoconducting $Zn_{1-x}Mn_xTe$

  • Kajitani, T.;Kamiya, T.;Sato, K.;Shamoto, S.;Ono, Y.;Sato, T.;Oka, Y.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.06a
    • /
    • pp.39-43
    • /
    • 1998
  • Single crystals of{{{{ { Zn}_{ 1-x} {Mn }_{x }{Te} }}}} with x=0.3-0.6 were prepared by the standard Bridgeman method. Diffuse neutron diffraction intensities due to the short range magnetic ordering is found in the vicinities of 1 1/2 0 reciprocal point and its equivalent point, indicating that the magnetic correlation of the clusters is the type III antiferromangetic one do the F-type Bravais class crystals, being identical with that of {{{{{ Cd}_{ 1-x} {Mn }_{x }Te }}}}. Neutron inelastic scattering measure-ment has been performed for {{{{{ Zn}_{ 0.6} { Mn}_{ 0.4}Te }}}} sample using the cold neutron spectrometer. AGNES. High resolution measurement with the energy resolution of {{{{ TRIANGLE E= +- .01meV}}}} was carried out in the temperature range from 10K to the ambient. Critical scattering, closely related with the spin glass transition, has been observed for the first time in this semimagnetic semi-conductor. The critical scattering is observed at temperatures in the vicinity of the spin glass transition temperature, 17K. The scattering is observed as a kind of quasielastic scattering in the reciprocal range where the elastic magnetic diffuse scattering has been observed, e.g., 11/20 reciprocal point, indicating the spin fluctuation has dynamic components in this material. Photoconductivity has been discovered below 150K in {{{{{ Zn}_{ 0.4} {Mn }_{0.6 } Te}}}}. The electric AC conductivity has been increased dramatically under the laser light with the wave lengths of {{{{ lambda =6328,5145 and4880 }}}}$\AA$ ,respectively. After the light was darkened, the conductivity was reduced to the original level after about 2000 seconds at 50K, being above the spin glass transition temperature. This phenomenon is the typical persistent photoconductivity; PPC which was similarly found in {{{{ { Zn}_{ 1-x} { Mn}_{x} Te}}}}.

  • PDF