Measurement of the construction structure of hot-heated cement using nitrogen adsorption method

질소흡착법을 사용한 고온 가열 시멘트의 세공구조 측정

  • 김민혁 (한국교통대학교 건축공학과) ;
  • 이건철 (한국교통대학교 건축학부)
  • Published : 2020.06.12

Abstract

Concrete has a lower thermal conductivity or thermal diffusion coefficient compared to other building materials, so it is widely used as fireproof compartment material or refractory material for structures. However, in the event of thermal damage such as fire, cement curing agents and aggregates act differently, resulting in heat generation or deterioration of tissue due to dehydration, resulting in deterioration of physical properties and fire resistance. Therefore, in this study, the processing structure of cement paste is measured through nitrogen absorption method. The test specimen is a cement paste of 40% W/C and is set at 1000 ℃ under heating temperature conditions. As the temperature rose, the micro-pore mass below was reduced based on about 0.01 감소m, but the air gap above that was increased.Thus, in the range of pores measured in nitrogen adsorption, the air mass tended to decrease under high temperature conditions.

Keywords