• 제목/요약/키워드: conductive line

검색결과 139건 처리시간 0.027초

금속 배선 제작을 위한 메탈 나노 파우더 임프린팅 공정기술 개발 (Development of Metal nano Powder Imprinting Process for Fabrication of Conductive Tracks)

  • 김진수;김호관;임지석;배형대;최민석;강신일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.371-374
    • /
    • 2007
  • A method for metal nano powder imprinting is proposed as a patterning process for conductive tracks that is inexpensive and scalable down to the nanoscale. Conductive tracks with line widths of $0.5{\sim}20{\mu}m$ were fabricated using this method. The processing conditions were optimized to avoid various types of defects, and to increase the degree of sintering and electric conductivity of the imprinted conductive tracks. The mean electric resistivity of the conductive tracks imprinted under optimum conditions was $8.95{\mu}{\Omega}{\cdot}cm$, which is in the range required for practical applications.

  • PDF

전력선 통신에서의 전자파 장해에 관한 연구 (A Study of Electromagnetic Interference in Power Line Communication)

  • 이진택;천동완;박영진;이원태;신철재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.620-625
    • /
    • 2004
  • In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dB$\mu$V/m.

고전도성 투명전극인 ITO/Ag/ITO 다층박막에 관한 광학적 분석 (Optical Analysis of the ITO/Ag/ITO Multiple Layers as a Highly Conductive Transparent Electrode)

  • 윤여탁;조의식;권상직
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.87-91
    • /
    • 2019
  • As a highly conductive and transparent electrode, ITO/Ag/ITO multilayers are fabricated using an in-line sputtering method. Optimal thickness conditions have been investigated in terms of the optical transmittance and the electrical conductance. Considering the optical properties, in this study, the experimental characteristics are analyzed based on theoretical phenomena, and they are compared with the simulated results. The simulations are based on the finite-difference-time-domain (FDTD) method in solving linear Maxwell equations. Consequently, the results showed that ITO/Ag/ITO multilayer structures with respective thicknesses of 39.2 nm/10.7 nm/39.2 nm are most suitable with an average transmittance of about 87% calculated for wavelengths ranging from 400-800 nm and a sheet resistance of about $7.1{\Omega}/{\square}$.

유한장 직선도체에 의한 자계의 계산 및 감소대책 (Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length)

  • 강대하
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

송전선에서 발생되는 자계에 의한 유도장해 해석 (Analysis of the influence of magnetic field generated from power transmission on the inductance interference)

  • 최세용;나완수;최명준;이세희;김동수;박일한;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1993-1995
    • /
    • 2000
  • In this paper, we calculate the magnetic field and analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as magnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics, transmission line height, conductive earth and mitigation wire are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried pipe line.

  • PDF

액체누설 감지용 테이프형 필름센서 (Tape-Type Liquid Leakage Film Sensor)

  • 유동근;김경신;유홍근;한국희;김동준;김정현;한상호;조광섭
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.146-154
    • /
    • 2011
  • 접착테이프 형태의 액체누설 감지 필름 센서와 이를 이용하고 경보 장치를 포함한 감지 시스템을 개발하였다. 액체누설 감지 필름형 테이프 센서는 베이스 필름층, 전도성 라인층, 보호 필름층으로 구성되며, 테이프의 두께 $300{\sim}500{\mu}m$, 폭 3.55 cm, 그리고 단위 테이프의 길이는 200 m이다. 전도성 라인층의 필름에는 3개의 전도선과 1개의 저항선이 있다. 이들은 도전성 은나노 잉크를 전자인쇄방식으로 설치한다. 이들 저항선과 전도선 사이에 액체가 누설되어 전기적으로 상호 통전되면, 두 선사이의 저항변화를 전압의 변화로 계측하여 누설 위치를 감지한다. 물을 포함한 전도성 액체에 대한 누설 위치 감지에서 길이 200 m에서 오차 범위는 ${\pm}1m$ 이내이다.

제강Slag 충진 폐플라스틱/복합 전도성 filler복합재료의 전자파 차폐 효과 (EMI Shielding Efficiency of Recycled plastic/Hybrid Conductive filer Composites filled Electro Arc furnace Slag)

  • 강영구;송종혁
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.80-85
    • /
    • 2004
  • Electromagnetic interference(EMI) shielding characteristics of composite filled with Cu flake and carbon brush powder as hybrid conductive filler and EAF slag have been studied. The coaxial transmission line method of ASTM D4935-99 was used to measure the EMI Shielding effectiveness of composites as formulation in frequency rage $100\~1,000MHz$ The SE also increases with the increase in flier loading. The hybrid filler filled composites show higher SE compared to that of only Cu flake. The correlation between SE and conductivity of the various composites is also discussed. The results indicate that the composites having higher filler loading$({\geq}40wt.\%)$ can be used for the purpose of safety materials to protect hazardous electromagnetic interference.

RF Power Absorption Enhancement of Magnetic Composites with Conductive Grid

  • Nam, Baek-Il;Kim, Jin-U;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.129-132
    • /
    • 2012
  • To evaluate the electromagnetic power absorption in near field, the magnetic composites with the conductive grids were simulated using the typical permeability frequency profiles. The transmission power absorptions of the magnetic composites on microstrip line were extracted by the 3D FEM simulation program of HFSS. The magnitudes of power absorptions were greatly enhanced up to 98% and broadened the absorbing frequency band over 5 GHz by the insertion of a conductive grid in magnetic composite. The initial frequency of the power absorption can controlled by the change of the ferromagnetic resonance frequencies of the magnetic composite.