Abstract

Electromagnetic interference(EMI) shielding characteristics of composite filled with Cu flake and carbon brush powder as hybrid conductive filler and EAF slag have been studied. The coaxial transmission line method of ASTM D4935-99 was used to measure the EMI Shielding effectiveness of composites as formulation in frequency rage $100\~1,000MHz$ The SE also increases with the increase in flier loading. The hybrid filler filled composites show higher SE compared to that of only Cu flake. The correlation between SE and conductivity of the various composites is also discussed. The results indicate that the composites having higher filler loading$({\geq}40wt.\%)$ can be used for the purpose of safety materials to protect hazardous electromagnetic interference.

Keywords

References

  1. C.C. Johnson and A. W. Guy in 'Biological Effectsof Electromagnetic Radiation' (J. M. OsepchuckEd.), IEEE Press, N. Y., PP. 47-43, 1987
  2. J. T. Hoback and J. J. Reilly, J. of Elastomers and Plastics, 20, 54, 1988 https://doi.org/10.1177/009524438802000106
  3. S. T. Shinn, Y. C. Fa, Mat. Sci. Eng. A 302, P.258, 2001
  4. Kawakubo, Chuba T. and Otaka, T., PlatingSurface Finishing, 78(2), P. 48, 1991
  5. C. Y. Huang and J. F. PAI, Eur. Polym. J. Vol.34, No. 2, PP. 261-267, 1998 https://doi.org/10.1016/S0014-3057(96)00248-0
  6. Pletcher and Welch, Industrial Electrochemistry,Ch. 8, Blackie A&P, 1993
  7. J. M. Crosby and J. E. Travis, Rubber World 193,30, 1985
  8. T. Katsura, M. R. Kamal, and L. A. Utracki,Polym. Compos. 6, P. 282, 1985 https://doi.org/10.1002/pc.750060413
  9. Taka, T., Synth. Metals, 41(43), P. 1177, 1991 https://doi.org/10.1016/0379-6779(91)91582-U
  10. L. W. Shacklette and N. F. Colaneri, J. Vinyl Technol., 14(2), P. 118, 1992 https://doi.org/10.1002/vnl.730140214
  11. M. Q. Zhang, Study on the Structure Property Relation of Electrical Conductive PolymericComposites, PhD thesis, Zhongshan University, Guangzhou, China, 1991
  12. C. Y. Huang, W. W. Mo, Surface and CoatingsTechnology 154, PP. 55-62, 2002 https://doi.org/10.1016/S0257-8972(01)01709-1
  13. S. S. Tzeng, F. Y. Chang, Materials Science and Engineering, A302, PP. 258-267, 2001 https://doi.org/10.1016/S0921-5093(00)01824-4
  14. N. C. Das, D. Khastgir, T. K. Chaki, A. Chak raborty, Composites, Part A31, PP. 1,069-1081, 2000
  15. W. M. Wright and G. W. Woodham, ConductivePlastics, Conductive Polymer and Plastics (J. M.Margolis, ed.), Chapman and Hall, New York, P.119, 1989
  16. A. Moguez, Composite materials modification for EMI shielding, Proceedings of the 9th International Conference of the Society for the Advancement of Material and Process Engineering European Chapter, Milan, pp. 237-252, 1988
  17. 강영구, 송종혁, Coupling agent 처리에 따른 난연 Composite의 기계적 특성 및 난연특성 연구, 2004, 한국산업안전학회 춘계학술발표회, pp.465-469, 2004
  18. S. J. Monte, Kenrich Petrochemicals Inc, Kenreact Reference Manual, pp. 65-69, 1985