• Title/Summary/Keyword: condition (A)

Search Result 53,717, Processing Time 0.066 seconds

A stability condition of minimal variance control with mismatch of time delay

  • Hashimoto, H.;Takenami, Y.;Akizuki, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.918-923
    • /
    • 1989
  • This paper presents a stability condition for Astrom's minimal variance control(MVC) with mismatch of time delay for a SISO ARMAX model containing time delay. The proof of the condition presented here is based on the characteristic equation in the feedback system and its magnitude. This condition, from easy numerical calculation, is able to find the stability of the feedback system without knowing the real time delay.

  • PDF

GLOBAL W1,2p ESTIMATES FOR NONDIVERGENCE PARABOLIC OPERATORS WITH POTENTIALS SATISFYING A REVERSE HÖLDER CONDITION

  • Pan, Guixia;Tang, Lin
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.5
    • /
    • pp.1357-1377
    • /
    • 2017
  • In this article, we first give the $L^p$ boundedness of the operator $D^2L^{-1}$ with BMO coefficients and a potential V satisfying an appropriate reverse $H{\ddot{o}}lder$ condition, then obtain global $W^{1,2}_p$ estimates for the nondivergence parabolic operator L with VMO coefficients and a potential V satisfying an appropriate reverse $H{\ddot{o}}lder$ condition.

On the ill - condition of reverse process from structural dynamic response data (구조계의 동적응답을 이용한 역해석에서의 악조건)

  • 양경택
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.390-397
    • /
    • 1998
  • An approach to identifying input forces is proposed using measured structural dynamic responses and its analytical model. The identification of input forces is a reverse process and ill-conditioned problem. Its solution is unstable and generally case dependent. In this paper, the ill-condition is described considering characteristic matrix which is defined by reduced dynamic stiffness matrix. Special attention is focused on the condition number of a characteristic matrix used in the solution algorithm of this reverse process. Simple example is presented in support of the ill-condition of a reverse process.

  • PDF

Adaptive Maintenance Using Machine Condition Diagnosis Technique (설비진단기술를 활용한 적응보전)

  • 송원섭;강인선
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.30
    • /
    • pp.73-79
    • /
    • 1994
  • This paper propose Adaptive Maintenance as a new type of maintenance for machine failures which are unpredictable. A purpose of adpative maintenance is to decrease inconsistency. In order to pick up some of problems the traditional maintenance policy, We discussed Time Based Maintenance(TBM) and Condition Based Maintenance(CBM) with Bath-Tub Curve. By using Machine Condition Diagnosis Technique (CDT), Monitored condition maintenance deals with the dynamic decision making for diagnosis procedures at maintenance and caution level. Adaptive Maintenance is a powerful tool for Total Production Maintenance(TPM).

  • PDF

WEAK AND STRONG CONVERGENCE FOR QUASI-NONEXPANSIVE MAPPINGS IN BANACH SPACES

  • Kim, Gang-Eun
    • Bulletin of the Korean Mathematical Society
    • /
    • v.49 no.4
    • /
    • pp.799-813
    • /
    • 2012
  • In this paper, we first show that the iteration {$x_n$} defined by $x_{n+1}=P((1-{\alpha}_n)x_n +{\alpha}_nTP[{\beta}_nTx_n+(1-{\beta}_n)x_n])$ converges strongly to some fixed point of T when E is a real uniformly convex Banach space and T is a quasi-nonexpansive non-self mapping satisfying Condition A, which generalizes the result due to Shahzad [11]. Next, we show the strong convergence of the Mann iteration process with errors when E is a real uniformly convex Banach space and T is a quasi-nonexpansive self-mapping satisfying Condition A, which generalizes the result due to Senter-Dotson [10]. Finally, we show that the iteration {$x_n$} defined by $x_{n+1}={\alpha}_nSx_n+{\beta}_nT[{\alpha}^{\prime}_nSx_n+{\beta}^{\prime}_nTx_n+{\gamma}^{\prime}_n{\upsilon}_n]+{\gamma}_nu_n$ converges strongly to a common fixed point of T and S when E is a real uniformly convex Banach space and T, S are two quasi-nonexpansive self-mappings satisfying Condition D, which generalizes the result due to Ghosh-Debnath [3].

Modeling Of Critical Flux Conditions In Crossflow Microfiltration

  • Kim, Su-han;Park, Hee-kyung
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.119-127
    • /
    • 2000
  • In the process of crossflow microfiltration, a deposit of cake layer tends to form on the membrane, which usually controls the performance of filtration. It is found, however, that there exist a condition under which no deposit of cake layer is made. This condition is called the sub-critical flux condition, and the critical flux here means a flux below which a decline of flux with time due to the deposit of cake layer does not occur. In order to study the characteristics of the critical flux, a numerical model is developed to predict the critical flux condition, and is verified with experimental results. For development of the model, the concept of effective particle diameter is introduced to find a representative size of various particles in relation to diffusive properties of particles. The model is found to be in good match with the experimental results. The findings from the use of the model include that the critical flux condition is determined by the effective particle diameter and the ratio of initial permeate flux to crossflow velocity.

  • PDF

Robust Stability Condition and Analysis on Steady-State Tracking Errors of Repetitive Control Systems

  • Doh, Tae-Yong;Ryoo, Jung-Rae
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.6
    • /
    • pp.960-967
    • /
    • 2008
  • This paper shows that design of a robustly stable repetitive control system is equivalent to that of a feedback control system for an uncertain linear time-invariant system satisfying the well-known robust performance condition. Once a feedback controller is designed to satisfy the robust performance condition, the feedback controller and the repetitive controller using the performance weighting function robustly stabilizes the repetitive control system. It is also shown that we can obtain a steady-state tracking error described in a simple form without time-delay element if the robust stability condition is satisfied for the repetitive control system. Moreover, using this result, a sufficient condition is provided, which ensures that the least upper bound of the steady-state tracking error generated by the repetitive control system is less than or equal to the least upper bound of the steady-state tracking error only by the feedback system.

Assessment of Slip Factor Models at Off-Design Condition (탈설계 조건에서의 미끄럼 계수 모텔들의 평가)

  • Yoon, Sung-Ho;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.410-415
    • /
    • 2000
  • Slip factor is defined as an empirical factor being multiplied to theoretical energy transfer for the estimation of real work input of a centrifugal compressor. Researchers have tried to develop a simple empirical model, for a century, to predict a slip factor. However most these models were developed on the condition of design point assuming inviscid flow. So these models often fail to predict a correct slip factor at off-design condition. In this study, we summarized various slip factor models and compared these models with experimental and numerical data at off-design condition. As a result of this study, Wiesner's and Paeng and Chung's models are applicable for radial impeller, but all the models are not suitable for backswept impeller. Finally, the essential avenues for future study is discussed.

  • PDF

Learning from the L2 Expository Text

  • Kim, Jung-Tae
    • English Language & Literature Teaching
    • /
    • v.10 no.3
    • /
    • pp.21-40
    • /
    • 2004
  • This study Questioned what happens in L2 reading comprehension of the expository text, as measured by recall and inference-making abilities, when a L2 reader was induced to develop a content schema about the topic of a target text, but the structure of that schema departs from the structure of the target text Seventy-four. Korean university students read either the same version text twice (consistent condition) or two different version texts (inconsistent condition) with a three-day interval between the two readings. The results of a verification test indicate that, for those subjects with higher L2 reading proficiency, the inconsistent condition was more beneficial than the consistent condition for the inference-making task. On the other hand, for lower-level L2 readers, the consistent condition was more favorable for the recall task. It was concluded that inducing a structurally inconsistent schema through an L2 pre-reading would be beneficial only when the reader's L2 linguistic ability is proficient enough to produce necessary propositions from the pre-reading.

  • PDF

The Development of Electric Ballast for a Instant Restart of Metalhalide Lamp (메탈헬라이드램프용 순시재점등 전자식안정기 개발)

  • 김수경;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.185-190
    • /
    • 2003
  • The most shortcoming of metalhalide lamps is what the instant restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition. Therefore it takes about five minutes to restart the metalhalide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 20kV at the both sides of lamp. The proposed electronic ballast is consist of a electromagnetic interference (EMI) filter, a power factor correction (PFC) circuit, a flyback converter, a half-bridge inverter, and a high voltage igniter circuit. By this composition we can restart the lamp with the voltage 20kV, even if the lamp is in the hot condition.

  • PDF