• Title/Summary/Keyword: concrete durability

Search Result 2,168, Processing Time 0.027 seconds

Characteristics of Chloride Diffusion and Compressive Strength in the Mortar containing C12A7 based Binder and Anhydrite (C12A7계 바인더와 무수석고를 혼입한 모르타르의 염화물 확산 및 압축강도 특성)

  • Byeong-Cheol, Lho;Yong-Sik, Yoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2022
  • In this study, as the preliminary research on the development of heating concrete members, compressive strength and accelerated chloride diffusion behavior in the mortar specimens containing C12A7 based binder and anhydrite was evaluated. Also, the effect of the mixing ratio of the citric acid based retarder was quantitatively evaluated by considering 4 levels of mixing cases. The compressive strength tests of the mortar specimen were performed referred to KS L ISO 679, and the accelerated chloride diffusion tests were performed according to NT BUILD 492 and ASTM C 1202. In the mortar with 0.3 % of retarder, the highest compressive strength was evaluated, which showed the strength development ratio of 127.6 % compared to the control case. It was considered that engineering performance was improved by effectively securing setting and curing time with 0.3 % of citric acid based retarder. As the result of the evaluation of the passed charge and the accelerated chloride diffusion coefficient, the evaluation results had similar behavior with the results of compressive strength. According to the previous study, the strength behavior and the chloride diffusion behavior had a linear relationship. The mixture showing the highest strength performance had the highest durability performance for chloride ingress, and the heating concrete development from this study will be performed in the future.

Self-Healing Property of Hardened Cement Paste (시멘트 페이스트 경화체의 self healing 특성)

  • Kim, Jae Young;Byun, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.297-304
    • /
    • 2008
  • It is well known that cracks in concrete decrease permeability and durability of concrete because cracks enhance the penetration of water or corrosive chemicals like as chlorides, carbon dioxides, sulfates and some others. But some of cracks in hardened cements may be sealed in case of contacting water. This phenomenon is called "self healing" and it has a close relation to hydration products newly formed on surfaces of cracks. Many studies on self healing in concretes commonly showed that CSH gel has been observed on crack surfaces. And some studies have reported that calcium hydroxides and ettringite were observed as well as CSH gel on crack surfaces. This study was carried out to investigate hydration products formed by self healing process and also examine the influence of waterproof admixture for concretes on self healing of cement. As a result of XRD, DSC, SEM and EDX analysis of crack surfaces, it was found that self healing of cement was related to CSH gel, calcium hydroxides and ettringite. And waterproof admixture increased fibrous (needle-like) hydration products which were in network form. It is estimated that such fibrous products are effective for self healing process of cement system.

Investigation of physicochemical properties, sustainability and environmental evaluation of metakaolin- granulated blast furnace slag geopolymer concrete

  • Anas Driouich;Safae El Alami El Hassani;Zakia Zmirli;Slimane El Harfaoui;Nadhim Hamah Sor;Ayoub Aziz;Jong Wan Hu;Haytham F. Isleem;Hadee Mohammed Najm;Hassan Chaair
    • Computers and Concrete
    • /
    • v.34 no.4
    • /
    • pp.489-501
    • /
    • 2024
  • Geopolymers are part of a class of materials characterized by properties combining polymers, ceramics, and cement. These include exceptionally high thermal and chemical stability, excellent mechanical strength and durability in aggressive environments. This work deals with the synthesis, characterization, and sustainability evaluation of GPGBFS-MK geopolymers by alkaline activation of a granulated blast furnace slag-metakaolin mixture. In the first step, elemental and oxide analyses by XRF and EDS showed that the main constituents of GPGBFS-MK geopolymers are silicon, sodium, and aluminium oxides. The structural analyses by XRD and FTIR confirmed that the geopolymerization for GPGBFS-MK geopolymers did occur, accompanied by the formation of disordered networks from the blends and a modification to the microstructure by the geopolymerization process. Similarly, the microstructural study made by SEM showed that the GPGBFS-MK geopolymers are constituted by aluminosilicates in the form of dense clusters on which are adsorbed particles of unreacted GBFS in the form of spheroids and white residues of the alkaline activating solution. In addition, the study of the sustainability evaluation of GPGBFS-MK geopolymers showed that the water absorption of geopolymeric materials is lower than that of OPC cement. As for the elevated temperature resistance, the analyses indicated an excellent elevated temperature resistance of GPGBFS-MK. In the same way, the study of the resistance to chemical aggressions showed that the GPGBFS-MK geopolymeric materials are unattackable, contrary to the OPC cement-based materials which are strongly altered.

A re-appraisal of scoring items in state assessment of NATM tunnel considering influencing factors causing longitudinal cracks (종방향균열 영향인자 분석을 통한 NATM터널 정밀안전진단 상태평가 항목의 재검토)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.479-499
    • /
    • 2019
  • State assessment of an operational tunnel is usually done by performing visual inspection and durability tests by following the detailed guideline for safety inspection (SI) and/ or precision inspection for safety and diagnosis (PISD). In this study, 12 NATM tunnels, which have been operational for more than 10 years, were inspected to figure out the cause of longitudinal cracks for the purpose of modifying the scoring items in the state assessment NATM tunnel related to the longitudinal crack and the thickness of concrete lining. All investigated tunnels were classified into four groups depending on the shape and usage of each tunnel. The causes of longitudinal crack occurrence were analyzed by investigating the correlations between the longitudinal crack and the following four factors: the patterns of ground excavation; construction state of primary support system; characteristics of material properties of the concrete lining; and thickness of lining which was obtained by Ground Penetration Radar (GPR) tests. It was found that influencing factors causing longitudinal cracks in the lining were closely related with the construction condition of the primary support system, i.e. shotcrete, rockbolt, and steel-rib; crack occurrences were not much affected by the excavation patterns. As for the properties of concrete lining materials, occurrence of the longitudinal crack was mostly affected by the following three items: w/c ratio; contents of cement; and strength of lining. When estimating the lining thickness of the concrete lining by GPR tests and taking thickness effect into account in the statement assessment, it was concluded that increase of the index score by an average of 0.03 (ranging from 0.01 up to 0.071) is needed; a more realistic way of state assessment should be proposed in which the increased index score caused by lack of lining thickness should be taken into account.

Assessment of Fire-Damaged Mortar using Color image Analysis (색도 이미지 분석을 이용한 화재 피해 모르타르의 손상 평가)

  • Park, Kwang-Min;Lee, Byung-Do;Yoo, Sung-Hun;Ham, Nam-Hyuk;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.83-91
    • /
    • 2019
  • The purpose of this study is to assess a fire-damaged concrete structure using a digital camera and image processing software. To simulate it, mortar and paste samples of W/C=0.5(general strength) and 0.3(high strength) were put into an electric furnace and simulated from $100^{\circ}C$ to $1000^{\circ}C$. Here, the paste was processed into a powder to measure CIELAB chromaticity, and the samples were taken with a digital camera. The RGB chromaticity was measured by color intensity analyzer software. As a result, the residual compressive strength of W/C=0.5 and 0.3 was 87.2 % and 86.7 % at the heating temperature of $400^{\circ}C$. However there was a sudden decrease in strength at the temperature above $500^{\circ}C$, while the residual compressive strength of W/C=0.5 and 0.3 was 55.2 % and 51.9 % of residual strength. At the temperature $700^{\circ}C$ or higher, W/C=0.5 and W/C=0.3 show 26.3% and 27.8% of residual strength, so that the durability of the structure could not be secured. The results of $L^*a^*b$ color analysis show that $b^*$ increases rapidly after $700^{\circ}C$. It is analyzed that the intensity of yellow becomes strong after $700^{\circ}C$. Further, the RGB analysis found that the histogram kurtosis and frequency of Red and Green increases after $700^{\circ}C$. It is analyzed that number of Red and Green pixels are increased. Therefore, it is deemed possible to estimate the degree of damage by checking the change in yellow($b^*$ or R+G) when analyzing the chromaticity of the fire-damaged concrete structures.

Fiber Optic Sensors for Smart Monitoring (스마트 모니터링용 광섬유센서)

  • Kim, Ki-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.137-145
    • /
    • 2006
  • Recently, the interests in structural monitoring of civil infrastructures are increased. Especially, as the civil infrastructures such as bridges, tunnels and buildings become large-scale, it is necessary to monitor and maintain the safety state of the structures, which requires smart systems that can supply long-term monitoring during the service time of the structures. In this paper, we investigated the possibilities of fiber optic sensor application to the various structures. We investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show good response to the structural behavior of the joint while electric gauges lack of sensitivity, durability and long term stability for continuous monitoring. We also apply fiber optic structural monitoring to the composite repaired concrete beam structure. Peel-out effects is detected with optical fiber Bragg grating sensors and the strain difference between main structure and repaired carbon sheets is observed when they separate each other. The real field test was performed to verify the behaviors of fiber Bragg grating sensors attached to the containment structure in Uljin nuclear power plant in Korea as a part of structural integrity test which demonstrates that the structural response of the non-prototype primary containment structures. The optical fiber Bragg grating sensor smart system which is the probable means for long term assessments can be applicable to monitoring of structural members in various civil infrastructures.

A Study on the Development and Performance Evaluation of Permeable GFRP Strengthening Panel for RC Structure (투수성 GFRP 보강 복합체 개발 및 투수성에 대한 연구)

  • Jo, Byung Wan;Kang, Seok Won;Park, Cheol;Kim, Jang Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.65-73
    • /
    • 2013
  • Recently the exterior attaching reinforcement method is being often used by using FRP (Fiber Reinforced Polymer) as a method of strengthening concrete structure. this FRP exterior attaching reinforcement method has several advantages like high intensity, stiffness, good durability and easy installment comparing to its weight. but its structure is airtight covered by reinforcement material whose water permeability is low and water can't be discharged, thus it may provoke a damage to the structure after a long while. the main purposes of this study are to develop GFRP reinforcement material which can discharge the surface water properly and to measure its special functions. for this, we have changed the normal reinforcement material to water permeable structure and measured its water permeance modulus by an indoor test which shows the process of water permeance with the parameter of contained GFRP quantity. also tried to verify the measured value of the water permeance modulus in theory by analyzing the numbers on water permeance process. the test result showed that the biggest quantity of water, 0.5129 g/h $m^2$ was discharged when the fiber contained quantity reached at 75% and the tensile strength was also biggest by 476.6MPa at 75%, so it appeared that COSREM GP panel with 75% fiber contained quantity is the best in ventilation and structure.

Effect of Time-dependent Diffusion and Exterior Conditions on Service Life Considering Deterministic and Probabilistic Method (결정론 및 확률론적 방법에 따라 시간의존성 염화물 확산계수 및 외부 영향인자가 내구수명에 미치는 영향)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • Service life evaluation for RC Structures exposed to chloride attack is very important, however the previous two methods(deterministic and probabilistic method) show a big difference. The paper presents a service life simulation using deterministic and probabilistic method with time-dependent diffusion coefficient. Three different cases are considered for diffusion coefficient, concrete cover depth, and surface chloride content respectively, and then the PDF(probability of durability failure) and the related service life are obtained. Through adopting time-dependent diffusion, the discrepancy between the two methods can be reduced, which yields reasonable service life. When diffusion coefficient increases from $2.5{\times}10^{-12}m^2/sec$ to $7.5{\times}10^{-12}m^2/sec$, the service life decreases to 25.5~35.6% level, and cover depth does from 75 mm to 125 mm, it increases to 267~311% level as well. In the case of surface chloride content from $5.0kg/m^3$ to $15.0kg/m^3$, it changes to 40.9~54.5%. The effect of cover depth is higher than the others by 8~10 times and also implies it is a key parameter to service life extension.

Influence of Bubble Sheet Applying Methods on Temperature of Exposed Joint Rebar at Wall Surface of Load-Bearing Wall Structure Building During Winter (동절기 벽식구조 건축물 벽부분의 버블시트 포설방법 변화가 이음부 노출철근의 온도에 미치는 영향)

  • Han, Cheon-Goo;Lee, Jea-Hyeon;Kim, Min-Sang
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • In this research, the surface covered curing method using the double-layered bubble sheet was evaluated. This double-layered bubble sheet has outstanding insulating performance with its low heat conductivity and high economic feasibility with its high durability. However, in the case of wall-typed building construction, the area of exposed rebar is curious on curing performance with the double-layered bubble sheet in spite of the double-layered bubble sheet showed favorable performance for slab. Therefore, in this research, regarding the actually constructed wall-typed apartment building, the most efficient curing method was suggested based on the evaluation of curing performance depending on temperature distribution depending on various location of covered or exposed rebar. As a result, the D method was determined as the most efficient curing method without any concern of early-age frost damage. However, by considering easiness of construction, the B method of covering the pieced double-layered bubble sheet on gap between rebars can be another option of desired result.

Design Strategy Analysis of the Germean Firm Braun (독일 브라운 사의 디자인 전략 분석)

  • 이병종
    • Archives of design research
    • /
    • no.18
    • /
    • pp.165-174
    • /
    • 1996
  • In the I950s the German firm Braun began to pursue a policy of uncompromising modem design for products aimed at the upper reaches of the market. Dr. Fritz Eichler as a head of design with Hans Gugelot and Otl Aicher in the Graduate School VIm developed the guide line of Braun Design strategy as the foundation of the corporate identity programme. In 1955 Dieter Rams joined the staff, and was largely responsible for establishing the formal characteristics of Braun Design and its further development. In the mid-1950s complete product programme of the firm Braun began to be re-designed, and these undoubtedly hit the market. New design line of the firm Braun, was an exclusive avantgarde movement at that time, which became to be the epitome of the idea of an objectifiable "Good Form". By the result in the 60s and 70s, when Braun product program was completely re-designed to the new line, Braun Design had a decisive influence on the design scene of the world. Braun Design is essentially functional and concrete, which depends on perfect fulfillment of purpose, precision, safety, durability, the quality of the product and, more recently, environmental compatibility is similarly balanced and unified approach, eliminating every unnecessary detail and concentrating on ordering essential elements. elements.

  • PDF