Browse > Article
http://dx.doi.org/10.5000/EESK.2006.10.6.137

Fiber Optic Sensors for Smart Monitoring  

Kim, Ki-Soo (홍익대학교 과학기술대학 재료공학부)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.10, no.6, 2006 , pp. 137-145 More about this Journal
Abstract
Recently, the interests in structural monitoring of civil infrastructures are increased. Especially, as the civil infrastructures such as bridges, tunnels and buildings become large-scale, it is necessary to monitor and maintain the safety state of the structures, which requires smart systems that can supply long-term monitoring during the service time of the structures. In this paper, we investigated the possibilities of fiber optic sensor application to the various structures. We investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show good response to the structural behavior of the joint while electric gauges lack of sensitivity, durability and long term stability for continuous monitoring. We also apply fiber optic structural monitoring to the composite repaired concrete beam structure. Peel-out effects is detected with optical fiber Bragg grating sensors and the strain difference between main structure and repaired carbon sheets is observed when they separate each other. The real field test was performed to verify the behaviors of fiber Bragg grating sensors attached to the containment structure in Uljin nuclear power plant in Korea as a part of structural integrity test which demonstrates that the structural response of the non-prototype primary containment structures. The optical fiber Bragg grating sensor smart system which is the probable means for long term assessments can be applicable to monitoring of structural members in various civil infrastructures.
Keywords
fiber bragg grating sensors; smart monitoring; beam-column joints; composite repaired structures; nuclear containment structures;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Measures, R. M., 'Fiber optic sensor considerations and developments for smart structures,' Proc. SPIE, Vol. 1588, 1991, pp. 282   DOI
2 Dewolf, J. T., Coon, P. E. and O'Leary, P. N., 'Continuous Monitoring of Bridge Structures,' Journal of Structural Engineering, Vol. 120, No.8, 1994, pp. 2437-2450   DOI   ScienceOn
3 Kim, K. S., Laszlo, Kollar and George, S. Springer, 'A Model of Embedded Fiber Optic Fabry-Perot Temperature and Strain Sensors,' Journal of Composite Materials, Vol. 27, 1993, pp. 1618-1662   DOI   ScienceOn
4 Laura De Lorenzis, Brian Miller and Antonio Nanni, 'Bond of Fiber-Reinforced Polymer Laminates to Concrete,' ACI Materials Journal, May-June, 2001
5 Kin-tak Lau, Libo Yuan, Li-min Zhou and Jingshen Wu, Chung-ho Woo 'Strain monitoring in FRP laminates and concrete beams using FBG sensors,' Composite Structures 51,2001, pp. 9-20   DOI   ScienceOn
6 Kim, K. S., 'Dynamic Strain Measurement with Fiber Bragg Grating Sensor System for Smart Structure,' Key Engineering, Vol. 279-273, 2004, pp. 2114
7 김기수, 'System Identification에 활용할 수 있는 광섬유센서 계측 시스템', 전산구조 공학, 제 16권 1호, 2003, pp. 39-43
8 하기주 '철근콘크리트 보-기둥 접합부의 내진성능 개선 보강 신기술', 한국지진공학회 논문집, 8권 2호, 2004, pp. 73-81
9 김기수 '광섬유 센서를 이용한 탄소섬유시트 보수보강 콘크리트구조물에서의 자기진단기법', 한국비파괴검사학회지, 23 권 2호, 2003, pp. 133-139
10 김기수 '광섬유센서를 이용한 원자력발전소 격납구조물의 가동전 가압팽창을 통한 구조건전성 시험', 한국복합재료학회지, 제 16권 6호, 2003, pp. 56-61
11 Kim, K. S. and Lee, H. J., 'An economical and multiple fibre grating system with a rapid response using code division multiple access,' Measurement Science and Technology (Institute of Physics), Vol. 12, 2001, pp. 906-908
12 김기수, '광섬유센서를 이용한 Beam-Column 조인트의 하중에 따른 변위 계측' 소음진동공학회 논문집, 제 15권 1호, 2004, pp. 3
13 Morey, W.W., Meltz, G. and Glenn, W.H., 'Fiber Optic Bragg Grating Sensors,' SPIE, Vol. 1169, 1989, pp. 98-106
14 Kersey, A. D., Koo, K. P. and Davis, M. A., 'Fiber Optic Bragg Grating Laser Sensors,' SPIE, Vol. 2292 Fiber Optic and Laser Sensors XII, 1994, pp. 102-112   DOI
15 Sarah, E. Mouring & Oscar Barton, Naval Academy, D.Kevin Simmons, 'External Retrofit of RIC Beams using Carbon Fiber Reinforced Polymer Laminates,' Stanford Univ, USA. Structural Faults & Repair conference, 2001