• 제목/요약/키워드: composite resins

검색결과 453건 처리시간 0.026초

심미성 수복재료의 착생경향에 관한 연구 (A STUDY ON THE STAINING TENDENCY OF ETHETIC RESTORATIVE MATERIALS)

  • 신흥수;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.372-383
    • /
    • 1995
  • The staining tendency of esthetic restorative material was very important factor for the people who are great concern about the esthetics. Most external stains were superficial and adjustable by routine prophylactic procedure. But some of these stains were remained under superficial stain. Some of these stains were accumulative on external tooth surface and it's removal alter the anatomic contour of restoration. The purpose of this study was to evaluate and compare the staining tendency of esthetic restorative materials to staining solution. In this study two glass-ionomer cements (Fuji II Glass-Ionomer Cement and Fuji II LC Glass-Ionomer Cement) and three composite resins (Sil$\ddot{u}$x Plus, APH and P-50) were evaluated and compared. Total 8 disc-shaped specimens of each material (17mm diameter, Imm thick) were immersed in coffee staining solution. These specimens were divided into one control and 3 experimental groups according to the immersion period as follows : Control: immersed in distilled water during each testing period Group 1 : immersed in staining solution for 6 hours Group 2 : immersed in staining solution for 24 hours Group 3 : immersed in staining solution for 72 hours Staining tendency was evaluated by total color difference(${\Delta}E^*$) of specimen before and after staining by spectorcolorimeteric readings (ColorQUEST Spectrophotometer, U.SA.). The results were as follows : 1. The total color differences of each testing materials were increased with time. 2. Among the experimental groups, the Fuji II Glass Ionomer Cement showed the highest total color difference(6.803) and the Silux Plus showed the lowest total color difference(1.637). 3. In comparison of glass ionomer cements, the total color difference of chemical cured glass ionomer cements(6.803) were higher than light cured glass ionomer cements(3.891) (P<0.01). 4. In comparison of composite resins, the P-50 showed the highest total color difference and the Silux Plus showed the lowest total color difference, but there was not significant difference among composite resins(P>0.05).

  • PDF

광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구 (A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES)

  • 정연정;민경산;이해형;조경모;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제28권4호
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).

상아질 접착제의 전단결합강도와 미세누출에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTHS AND MICROLEAKAGES OF THREE BONDING AGENTS ON DENTIN)

  • 김정호;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.680-692
    • /
    • 1997
  • New bonding agent systems have been supplied which operators can simply apply to conditioned tooth surfaces. The purpose of this study was to evaluate the shear bond strengths and the microleakages of three bonding agents and composite resins to dentin. Seventy-five extracted human maxillary and mandibular molar teeth were used in this study. For the shear bond strength test, the entire occlusal dentin surfaces of thirty teeth were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A). For the microleakage test, Class V cavities were prepared in the buccal surfaces of fourtyfive teeth. They were randomly assigned into 3 groups according to dentin bonding agents ($Scotchbond^{TM}$ Multi-Purpose plus, ONE-$STEP^{TM}$ and Prime & $Bond^{TM}$)and composite resins (Z-100, $Aelitefil^{TM}$ and TPH $Spectrum^{TM}$) to be used. Bonding agents and composite resins were bonded to exposed dentin surfaces of the tooth crown and to Class V cavities on the buccal surfaces respectively according to manufacturer's directions. The shear bond strengths were measured by universal testing machine($U^{TM}$ AGS-100, Japan). In addition, the degree of micro leakage at the occlusal and gingival margin was examined by 2 % methylene blue and stereomicroscope(Olymous SZH 10, Japan). The results were as follows: 1. The shear bond strength to dentin was the highest value in SBMP-Plus group($16.68{\pm}7.38$ MPa) and the lowest value in Prime & Bond group($11.61{\pm}5.82$ MPa), but there was no significant difference of shear bond strength among three groups. 2. The degree of microleakage at both occlusal and gingival margin was showed the lowest in SBMP-Plus group and the highest in ONE-STEP group. 3. At both occlusal and gingival margin, there was significant difference of microleakage between SBMP-Plus and ONE-STEP/ Prime & Bond groups(p<0.05), but no significant difference of microleakage between ONE-STEP and Prime & Bond group(p>0.05).

  • PDF

Polymer matrices for carbon fiber-reinforced polymer composites

  • Jin, Fan-Long;Lee, Seul-Yi;Park, Soo-Jin
    • Carbon letters
    • /
    • 제14권2호
    • /
    • pp.76-88
    • /
    • 2013
  • Carbon fibers (CFs) have high service temperature, strength, and stiffness, and low weight. They are widely used as reinforcing materials in advanced polymer composites. The role of the polymer matrix in the composites is to provide bulk to the composite laminate and transfer load between the fibers. The interface between the CF and the resin matrix plays a critical role in controlling the overall properties of the composites. This paper aims to review the synthesis, properties, and applications of polymer matrices, such as thermosetting and thermoplastic resins.

Condensed Tannin을 포함한 접착제에서 Tannin과 Formaldehyde의 반응에 관한 연구 (Reaction Study of Tannin with Formaldehyde in the Adhesive Containing Condensed Tannin)

  • 정경호
    • 한국염색가공학회지
    • /
    • 제4권3호
    • /
    • pp.116-121
    • /
    • 1992
  • This paper is on for a material to replace the petroleum-based resins used as adhesives for the fiber in rubber composite materials. The study limited to the reaction properties of tannin with formaldehyde. Tannin-formaldehyde(TF) reactions were carried out in aqueous media. Rates of reaction were strongly dependent on concentration, temperature, pH, and the mole ratio of tannin to formaldehyde. Viscosities of reaction mixtures were followed up to gelation. The reactivity of tannin-formaldehyde resins was greater than that of resorcinol-formaldehyde resins. To formulate an adhesive, a styrene-butadiene-vinyl pyridine terpolymer latex(L) was added to the TF. This preliminary results suggest that the condensed tannins have considerable promise as substitutes for resorcinol used in resin formulation for bonding of fiber to rubber.

  • PDF

광중합 복합레진의 압축강도에 대한 실험적 연구 (A Study of Compressive Strength of Two Resins on the Cavity Forms)

  • 박경훈;이찬영;이승종;박동수;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제12권2호
    • /
    • pp.83-90
    • /
    • 1987
  • Composite resins has been widely used in dental clinics because of esthetic restoration. The aim of this study was to assess the effects of the cavity designs on the compressive stress of resin restoration. So, the author made the standardized specimen of four types (Type of speciemen are width 1.5mm, depth 2mm, width 1.5mm, depth 3mm, width 2mm, depth 2mm, width 2mm, depth 3mm). The compressive strength was measured by universal testing machine (Tong Kwang Co.) The results indicating following; 1. There was a statistic significance of compressive strength between four cavity forms. 2. There was no difference of significance of compressive strength between two resins. 3. There was a significance of compressive strength between depth 3mm width 1.5mm and depth 3mm width 2mm.

  • PDF

Fabrication and Characterization of Carbon Nanotube/Carbon Fiber/Polycarbonate Multiscale Hybrid Composites

  • Cho, Beom-Gon;Hwang, Sang-Ha;Park, Young-Bin
    • Composites Research
    • /
    • 제29권5호
    • /
    • pp.269-275
    • /
    • 2016
  • Multiscale hybrid composites, which consist of polymeric resins, microscale fibers and nanoscale reinforcements, have drawn significant attention in the field of advanced, high-performance materials. Despite their advantages, multiscale hybrid composites show challenges associated with nanomaterial dispersion, viscosity, interfacial bonding and load transfer, and orientation control. In this paper, carbon nanotube(CNT)/carbon fiber(CF)/polycarbonate(PC) multiscale hybrid composite were fabricated by a solution process to overcome the difficulties associated with controlling the melt viscosity of thermoplastic resins. The dependence of CNT loading was studied by varying the method to add CNTs, i.e., impregnation of CF with CNT/PC/solvent solution and impregnation of CNT-coated CF with PC/solvent solution. In addition, hybrid composites were fabricated through surfactant-aided CNT dispersion followed by vacuum filtration. The morphologies of the surfaces of hybrid composites, as analyzed by scanning electron microscopy, revealed the quality of PC impregnation depends on the processing method. Dynamic mechanical analysis was performed to evaluate their mechanical performance. It was analyzed that if the position of the value of tan ${\delta}$ is closer to the ideal line, the adhesion between polymer and carbon fiber is stronger. The effect of mechanical interlocking has a great influence on the dynamic mechanical properties of the composites with CNT-coated CF, which indicates that coating CF with CNTs is a suitable method to fabricate CNT/CF/PC hybrid composites.

ABS 수지의 내열성 강화를 위한 화합물인 N-phenylmaleimide의 상업화를 위한 촉매 개발 (Development of a Catalyst for the Commercialization of N-phenylmaleimide for Strengthening the Heat Resistance of ABS Resins)

  • 정헌주;양윤승;김석찬
    • 공업화학
    • /
    • 제28권6호
    • /
    • pp.645-648
    • /
    • 2017
  • 전량 수입에 의존하고 있는 ABS 수지의 내열성 강화를 위한 화합물인 N-phenylamleimide (PMI)의 상업화를 위한 촉매개발을 완료하였다. Maleic anhydride와 aniline과 반응을 통하여 중간체인 N-phenylmaleamic acid (PMA)를 정량적으로 얻은 후, PMI를 얻기 위한 촉매를 탐색하였다. Zinc acetate/$Et_3N$의 복합 촉매가 단일 산 촉매보다 우수한 성능을 보임을 확인하였다. 개발된 복합 촉매를 사용하여 추가 정제 공정 없이 90% 수율과 99.3%의 순도로 PMI를 합성할 수 있었다.

가시광선과 아르곤 레이저로 복합레진 중합시 미세누출에 관한 비교 연구 (MICROLEAKAGE OF COMPOSITE RESINS POLYMERIZED WITH ARGON LASER AND VISIBLE LIGHT)

  • 장기택;정태련;김종철
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.899-905
    • /
    • 1996
  • For the purpose of evaluation of microleakage of class V resin restoration, 64 extracted bovine teeth were filled with two kinds of light curing composite resins(Z-100, Clearfil) and polymerized with 40 seconds of visible light and with 10 seconds of argon laser. After 1000 thermocycling($5^{\circ}C/55^{\circ}C$), specimens were placed in 1 % methylen blue dye solution for 72 hours in $37^{\circ}C$ water bath. The specimens were sectioned at center of filling body and the degree of dye penetration was observed with a stereomicroscope. The following results were obtained, 1. Differences of the microleakage of resin restorations polymerized with 10 seconds of argon laser and 40 seconds of visible light were statistically insignificant. 2. There was more microleakage in Z-100 than clearfil and there was a statistical significancy (p<0.05).

  • PDF

광조사 강도가 복합레진의 중합반응속도에 미치는 영향에 관한 실시간 체적측정법을 이용한 연구 (EFFECT OF LIGHT INTENSITY ON THE POLYMERIZATION RATE OF COMPOSITE RESIN USING REAL-TIME MEASUREMENT OF VOLUMETRIC CHANCE)

  • 라성호;이인복;김창근;조병훈;이광원;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.135-141
    • /
    • 2002
  • Objectives : The aim of this study is to evaluate the effect of light intensity variation on the polymerization rate of composite resin using IB system (the experimental equipment designed by Dr. IB Lee) by which real-time volumetric change of composite can be measured. Methods : Three commercial composite resins [Z100(Z1), AeliteFil(AF), SureFil(SF)] were photopolymerized with Variable Intensity Polymerizer unit (Bisco, U.S.A.) under the variable light intensity (75/150/225/300/375/450mW$^2$) during 20 sec. Polymerization shrinkage of samples was detected continuously by IB system during 110 sec and the rate of polymerization shrinkage was obtained by its shrinkage data. Peak time(P.T.) showing the maximum rate of polymerization shrinkage was used to compare the polymerization rate. Results : Peak time decreased with increasing light intensity(p<0.05). Maximum rate of polymerization shrinkage increased with increasing light intensity(p<0.05). Statistical analysis revealed a significant positive correlation between peak time and inverse square root of the light intensity (AF:R=0.965, Zl:R=0.974, SF:R=0.927). Statistical analysis revealed a significant negative correlation between the maximum rate of polymerization shrinkage and peak time(AF:R=-0.933, Zl:R=-0.892, SF:R=-0.883), and a significant positive correlation between the maximum rate of polymerization shrinkage and square root of the light intensity (AF:R=0.988, Zl:R=0.974, SF:R=0.946). Discussion and Conclusions : The polymerization rate of composite resins used in this study was proportional to the square root of light intensity Maximum rate of polymerization shrinkage as well as peak time can be used to compare the polymerization rate. Real-time volume method using IB system can be a simple alternative method to obtain the polymerization rate of composite resins.