Abstract
Objectives : The aim of this study is to evaluate the effect of light intensity variation on the polymerization rate of composite resin using IB system (the experimental equipment designed by Dr. IB Lee) by which real-time volumetric change of composite can be measured. Methods : Three commercial composite resins [Z100(Z1), AeliteFil(AF), SureFil(SF)] were photopolymerized with Variable Intensity Polymerizer unit (Bisco, U.S.A.) under the variable light intensity (75/150/225/300/375/450mW$^2$) during 20 sec. Polymerization shrinkage of samples was detected continuously by IB system during 110 sec and the rate of polymerization shrinkage was obtained by its shrinkage data. Peak time(P.T.) showing the maximum rate of polymerization shrinkage was used to compare the polymerization rate. Results : Peak time decreased with increasing light intensity(p<0.05). Maximum rate of polymerization shrinkage increased with increasing light intensity(p<0.05). Statistical analysis revealed a significant positive correlation between peak time and inverse square root of the light intensity (AF:R=0.965, Zl:R=0.974, SF:R=0.927). Statistical analysis revealed a significant negative correlation between the maximum rate of polymerization shrinkage and peak time(AF:R=-0.933, Zl:R=-0.892, SF:R=-0.883), and a significant positive correlation between the maximum rate of polymerization shrinkage and square root of the light intensity (AF:R=0.988, Zl:R=0.974, SF:R=0.946). Discussion and Conclusions : The polymerization rate of composite resins used in this study was proportional to the square root of light intensity Maximum rate of polymerization shrinkage as well as peak time can be used to compare the polymerization rate. Real-time volume method using IB system can be a simple alternative method to obtain the polymerization rate of composite resins.
Keywords
Composite Resin; Volumetric Shrinkage; Rate of Polymerization; Light Intensity; IB system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Mehl A, Hickel R and Kunzelmann KH : Physical properties and gap formation of light-cured composites with and without 'softstart-polymerization', J Dent 25(3-4):321-330.1997   DOI   ScienceOn
2 Venhoven BAM. de Gee AJ and Davidson CL : Light initiation of dental resins : dynamics of the polymerization, Biomat 17:2313-2318,1996   DOI   ScienceOn
3 Odian G : Principles of polymerization. 3rd ed. John Wiley & Sons. Inc. p198-243, 286-290,1991
4 Rueggeberg F and Tamareselvy K : Resin cure determination by polymerization shrinkage, Dent Mater 11(4):265-268,1995   DOI   ScienceOn
5 Feilzer AJ, de Gee AJ and Davidson CL : Curing contraction of composites and glass-ionomer cements, Journal of Prosthetic Dentistry 59:297-300,1988   DOI   ScienceOn
6 Davidson CL and de Gee AJ : Relaxation of polymerization contraction stresses by flow in dental composites, J Dent Res 63(2): 146-148, 1984   DOI   ScienceOn
7 Feilzer AJ, de Gee AJ and Davidson CL : Quantitative determination of stress reduction by flow in composite restorations. Dental Materials 6: 167-171,1990   DOI   ScienceOn
8 Loshaek S and Fox TG : Cross-linked polymers. I. Factors influencing the efficiency of cross-linking in copolymers of methyl methacrylates and glycol dimethacrylates, J. Am. Chem. Soc. 75:3544-3550, 1953   DOI
9 Feilzer AJ, Dooren LH, de Gee AJ and Davidson CL : Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface. Eur J Oral Sci 103:322-326,1995   DOI   ScienceOn
10 Ruyter IE and Gyorosi PP : An infrared spectroscopic study of sealants. Scand J Dent Res 84(6):396-400,1976   PUBMED
11 Kanca J and Suh BI : Pulse activation:reducing resinbased composite contraction stresses at the enamel cavosurface margins, Am J Dent 12(3):107-112, 1999   PUBMED
12 Suh BI and Cripe CA : Light intensity and exposure time effect on light-cured composites. IADR Abst.#73:p.1-6,1998
13 Venhoven BAM, de Gee AJ and Davidson CL : polymerization contraction and conversion of light-curing BisGMA-based methacrylate resins. Biomaterials 14(11):871-875,1993   DOI   ScienceOn
14 Antonucci JM and Toth EE : Extent of polymerization of dental resins by differential scanning calorimetry, J Dent Res 62(2):121-5,1983   DOI   ScienceOn
15 Tobolsky AV, Leonard F and Roeser GP : Use of polymerizable ring compounds in constant volume polymerization, J. Polym. Sci. 3:604-606,1948   DOI   ScienceOn
16 Lee lB : A new method - Real time measurement of the initial dynamic volumetric shrinkage of composite resins during polymerization, The J of kor academy of conservative dentistry 26(2):134-140,2001
17 Retief DH : Do adhesives prevent microleakage?, Int Dent J. 44(1):19-26,1994   PUBMED
18 Lee IB, Jung KH and Um CM : Thermal analysis of the dual cured resin cements according to curing condition, The J of kor academy of conservative dentistry 24(2):265-285,1999