• 제목/요약/키워드: complex electric field

검색결과 130건 처리시간 0.026초

Preliminary study on a 3D field permanent magnet flux switching machine - from tubular to rotary configurations

  • Wang, Can-Fei;Shen, Jian-Xin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.505-508
    • /
    • 2012
  • A permanent magnet flux switching (PMFS) machine has a simple rotor, whilst both magnets and coils are set in the stator, resulting in easy removal of heat due to both copper loss and eddy current loss in magnets. However, the volume of magnets used in PMFS machines is usually larger than in conventional PM machines, and leakage flux does exist at the non-airgap side. To make full use of the magnets and gain higher power density, a novel 3-dimensional (3D) field PMFS machine is developed. It combines merits of the tubular linear machine, external-rotor rotary machine and axial-flux rotary machine, hence, offers high power density and peak torque capability, as well as efficient utility of magnets owing to the unique configuration of triple airgap fields.

전자파 차폐효과와 방사고주파 내성과의 상관관계에 대한 연구 (A Study on the Correlation between Shielding Effect of Electromagnetic Field and Immunity of Radiated Radio Frequency)

  • 박찬원;안광희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2462-2464
    • /
    • 1999
  • All electric and electronic appliances require their own electromagnetic compatibility. So an industrially advanced nations have made many standards for regulation for their profits thus the researches on the electro-magnetic shielding effect(SE) are being increased. But the SE can not proved its effect by a theory alone because of complex-material problems. This study Present the correlation of the SE and immunity of radiated radio frequency of the electromagnetic field. We have analyzed the theory of shielding effect to the shield texture. It has been proved that experimental results showed this effects have intensive relations to the electromagnetic field immunity.

  • PDF

복합 연자성 소재의 전동기 코어손실 예측을 위한 실험적 분석 (Experimental Analysis for Core Losses Prediction in Electric Machines by Using Soft Magnetic Composite)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.471-476
    • /
    • 2021
  • 분말 야금 기술에 의한 복합 연자성 재료는 전기기기에 일반적으로 사용되는 종래의 전기강판보다 많은 장점을 가지고 있으며, 그 관련 기술은 최근에 상당한 발전을 거듭하고 있다. 복합 연자성 재료는 일반적으로 분말의 형태로 인해 자기적 등방성 가지므로 3차원 자속 및 복잡한 구조의 전기기기 구성에 적합하다. 하지만 SMC와 같이 등방성 자기 특성을 가지는 재료는 복잡한 벡터 히스테리시스를 가지므로 정확한 손실 특성을 예측하는 것이 매우 어렵다. 따라서 본 논문에서는 전기강판 및 SMC의 링 타입 시편을 제작하고 시편 크기에 따라 자기적 특성을 측정한 후, 측정된 자기적 정보를 이용하여 800Hz 이상에서 구동하는 고속 영구자석 전동기의 전자계 해석을 수행하였다. 또한, 해당 모델의 시작품을 제작하고 효율 측정 및 비교를 통해 본 논문의 신뢰성을 입증하였다.

NaCl 전해질 농도 변화에 따른 다공질 탄소전극의 전기적 특성 (Electrical Characteristics of Porous Carbon Electrode According to NaCl Electrolyte Concentration)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.814-819
    • /
    • 2010
  • Porous carbon electrodes with wooden materials are manufactured by molding carbonized wood powder. Electrical properties of the interface for electrolyte and porous carbon electrode are investigated from viewpoint of NaCl electrolyte concentration, capacitance and complex impedance. Density of porous carbon materials is 0.47~0.61 g/$cm^3$. NaCl electrolytic absorptance of the porous carbon materials is 5~30%. As the electrolyte concentration increased, capacitance is increased and electric resistance is decrease with electric double layer effect of the interface. The electric current of the porous carbon electrode compared in the copper and the high density carbon electrode was improved on a large scale, due to a increase in surface area. The circuit current increased as the distance between of the porous carbon electrode and the zinc electrode decreased, due to increase in electric field. Experimental results indicated that the current properties of galvanic cell could be improved by using porous carbon electrode.

하전된 멤브레인 미세기공에서의 계면동전기적 유동에 의한 흐름전위: 비선형 Poisson-Boltzmann 전기장을 갖는 경우 (Electrokinetically Flow-Induced Streaming Potential Across the Charged Membrane Micropores: for the Case of Nonlinear Poisson-Boltzmann Electric Field)

  • Myung-Suk Chun
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.37-46
    • /
    • 2003
  • 하전된 멤브레인 미세기공으로 유체가 흐르는 경우는 계면동전기 효과가 작용하게 된다. 비선형 Poisson-Boltzmann 전기장과 흐름에 의해 유발되는 전기장 사이의 정전상호작용을 운동방정식의 외부작용 힘으로 고려하였다. 유한차분법으로 정전위 분포를 우선 산출하고, 이어서 Green 함수로 슬릿형 기공에 대한 Navier-Stokes 식의 해석해를 구하였다. 계면동전기적 유동에 의한 흐름전위를 관련된 물리화학적 인자들의 함수로 유도되는 해석적인 명확한 표현으로 제시하였다. 전기이중층, 표면전위, 그리고 기공벽면의 하전조건의 영향에 따른 유속분포와 흐름전위 변화를 고찰하였다 계산결과, 전기이중층 두께나 표면전위가 증가함에 따라 평균유속은 감소하는 반면에 흐름전위는 증가하였다.

전력계통의 고장 및 보호계전기 동작에 대한 분석 (The Analysis of Fault and Relay Operation in System of Power Network)

  • 김호표;한상섭;박응주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.27-29
    • /
    • 2001
  • As the amount of electric power consumption is increasing rapidly, the power systems are complex and growing larger. It is required that the quality of electricity is better. To satisfy this demands It is required to analyze the data of the fault accurately and then to find a cause and to enforce a countermeasure. We analyzed the fault of transmission & substation installation over 66kV statistically to operate the power system well. We introduced the faults that are classified into the cause, the facilities, the voltage. This paper explains the experience of the fault in electric power coporation that is operating the large power system. This paper will be meaningful. because this paper gives the data of real power system. We wish that the reliability of power suppliment will be improved, as using this paper properly and this paper is helpful to the growth of this field and the development of technology.

  • PDF

데이터 분석 알고리즘을 이용한 철손 측정(2차원 B-H 관계) (A study on Iron Loss Measurement In Electric Machines)

  • 이동현;홍선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2347-2349
    • /
    • 2004
  • The iron loss in electric machines takes large part of machine losses and the reduction of iron loss brings the increase of the efficiency. In the rotating machines, however it is very difficult to calculate result because the measuring processes are very complex and laborious. As is well known, the relation between the flux density B and the magnetic field intensity H relation is not linear. For the iron loss, B and H must be measured and usually B becomes the reference wave(sine wave) and the following H is measured using H-coil. To make the B as sine wave, B is controlled by some devices. The error is controlled to become zero by the proposed algorithm which uses the bisection algorithm. The experiments are compared with the simulation results, and they show acceptable agreements.

  • PDF

데이터 분석 알고리즘을 이용한 철손 측정 (A study on Iron Loss Measurement in Electric Machines)

  • 이동현;홍선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.49-51
    • /
    • 2004
  • The iron loss in electric machines takes large part of machine losses and the reduction of iron loss brings the increase of the efficiency. In the rotating machines, however it is very difficult to calculate the iron loss and to get the exact experiment result because the measuring precesses are very complex and laborious. As is well known, the relation between the flux density B and the magnetic field intensity H relation is not linear. For the iron loss, B and H must be measured and usually B becomes the reference wave(sine wave) and the following H is measured using H-coil. To make the B as sine wave, B is controlled by some devices. The error is controlled to become zero by the proposed algorithm which uses the bisection algorithm. The experiments are compared with the simulation results, and they show acceptable agreements.

  • PDF

The Effect of a High Temperature Superconducting Patch on a Rectangular Microstrip Antenna

  • Chebbara, Fouad;Amir, Mounir;Fortaki, Tarek
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.277-281
    • /
    • 2009
  • The complex resonant frequency problem of a superconductor patch is formulated in terms of an integral equation which is the kernel of a dyadic Green's function. To include the effect of the superconductivity of the microstrip patch, the surface complex impedance of the superconductor film is introduced using the two fluids model of Gorter and Casimir. The Galerkin procedure is used in the resolution of the electric field integral equation. Numerical results concerning the effect of the operating temperature of a superconductor patch on the characteristics of the antenna are presented.

주파수 의존성에 따른 고분자 LED의 유전 분산 거동에 관한 연구 (AC dielectric response of poly(p-phenylenevinylene) light emitting devices)

  • 이철의;김세헌;장재원;김상우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2000
  • AC impedance measurements on poly-p-phenylenevinylene (PPV) LEDs in the frequency range between 10 Hz and 10$\^$6/ Hz were carried out. The complex-plane impedance spectra indicate that PPV devices can be represented by equivalent circuits that corresponds to the bulk and interfacial regions at high and low frequencies, respectively. As a result of complex impedance analysis through the separation of bulk and interfacial region impedances, increase of forward bias in Al/PPV/ITO devices gave rise to relative decrease of the interfacial region impedance. Above the electric field of 10$\^$6/ V/cm the PPV device showed a space charge limited current (SCLC) conduction. The dependence of the transport mechanism and dielectric properties on the applied bias voltage is discussed.

  • PDF