• 제목/요약/키워드: comparison matrix

검색결과 924건 처리시간 0.026초

컬럼 비교를 통한 Ferimzone Z 및 E 입체 이성질체의 물질 분리 및 HPLC-MS/MS를 활용한 현미 중 미량잔류분석법 개발 (Column Comparison for the Separation of Ferimzone Z and E Stereoisomers and Development of Trace Residue Analysis Method in Brown Rice Using HPLC-MS/MS)

  • 정문주;김소희;은혜란;이예진;김수민;백재운;이윤희;신용호
    • 한국환경농학회지
    • /
    • 제42권3호
    • /
    • pp.203-210
    • /
    • 2023
  • Ferimzone Z is a fungicide for effectively controlling rice blast. Under light irradiation conditions, it undergoes a rapid conversion to its E-stereoisomer. Given the importance of isomers in risk assessments of residues in crops, an analytical method was developed for individual isomer quantification. A comparative analysis performed using two columns in HPLC-MS/MS demonstrated that the isomers were successfully separated using the Cadenza column. For the brown rice sample preparation, 5 g of the homogenized sample was saturated with 7 mL of water. The sample was then extracted with a 10 mL mixed solvent of acetonitrile and ethyl acetate (1:1, v/v) that contained 0.1% formic acid, and it was subsequently partitioned with magnesium sulfate and sodium chloride. The upper layer was purified using dSPE containing C18 and PSA sorbents. The established method was subjected to method validation, and it showed recovery rates of 90.6-98.8% (RSD ≤ 3.9%) at concentrations of 0.01, 0.1, 2 mg/kg, with a soft matrix effect (%ME) ranging from -3.1% to +6.5%. This method can be employed in monitoring studies of brown rice to determine the conversion ratio from the Z isomers to the E isomers.

사질토 지반에 놓인 지진하중을 받는 말뚝 기초 시스템의 고유 진동수 예측 (Prediction of the Natural Frequency of Pile Foundation System in Sand during Earthquake)

  • 양의규;권선용;최정인;김명모
    • 한국지반공학회논문집
    • /
    • 제26권1호
    • /
    • pp.45-54
    • /
    • 2010
  • 말뚝 구조물의 동적 거동을 분석하고 지진파에 대한 공진 안정성을 확보하기 위해서는 고유 진동수를 합리적으로 산정하는 것이 중요하다. 본 연구에서는 간단한 질량 - 스프링 모델을 이용하여 지진 하중을 받는 말뚝 구조물의 고유 진동수를 간편하면서도 효율적으로 예측할 수 있는 방법을 모색하였다. 고유진동수 산정 결과에 큰 영향을 미치는 지반-말뚝 간 스프링 강성을 지반반력상수와 p-y 곡선 그리고 지반 탄성계수 등을 이용하여 결정하고, 이들을 이용하여 계산한 고유진동수를 1g 진동대 실험에서 계측한 고유진동수와 비교한 결과, 지반반력상수를 이용한 Reese(1974) 방법과 동적 p-y 중추 곡선을 이용한 Yang(2009)의 방법을 이용하여 스프링 강성을 산정하는 것이 가장 우수한 결과를 나타내었는데, 건조토에 위치한 말뚝구조물에서는 5% 이내의 오차를 보였으며, 포화토에 위치한 말뚝 구조물의 경우에는 진동 중에 과잉간극수압의 발생여부에 따라 5%에서 40% 사이의 오차를 나타내었다.

픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가 (Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel)

  • 전승익;이봉구
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.359-365
    • /
    • 2023
  • 높은 초당 프레임 속도와 낮은 영상지연을 갖는 동영상 엑스레이 디텍터의 요구조건을 만족하기 위해서는 픽셀내 포토다이오드와 금속 배선간 중첩 영역의 기생정전용량을 최소화하여야 한다. 본 연구에서는 리드아웃 박막트랜지스터, 리셋 박막트랜지스터, 그리고 포토다이오드로 픽셀이 구성된 듀오픽스TM(duoPIXTM) 동영상 엑스레이 영상센서를 처음으로 제시하였다. 이후 150 × 150 mm2 영상영역, 73 ㎛ 픽셀 크기, 2048 × 2048 해상도(4.2 M pixels), 최대 초당 50 프레임의 특성을 갖는 duoPIXTM 동영상 엑스레이 디텍터를 제작하여 초당 프레임 속도, 감도, 노이즈, MTF, 영상지연과 같은 엑스레이 영상 성능을 기존 엑스레이 영상센서를 적용한 동영상 엑스레이 디텍터와 비교 평가하였다. 평가 결과 이전 연구에서 기대했던 것과 같이 duoPIXTM 동영상 엑스레이 디텍터가 기존 동영상 엑스레이 디텍터 대비 모든 특성에서 우위의 성능을 보여 주었다.

강-콘크리트 합성구조물의 비선형해석을 위한 화이버 유한요소 혼합법 (Fiber Finite Element Mixed Method for Nonlinear Analysis of Steel-Concrete Composite Structures)

  • 박정웅;김승억
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.789-798
    • /
    • 2008
  • 강성도법에서는 평형상태의 해석을 통해 구조물의 변위를 바로 산정할 수 있다. 그러나 변위형상함수를 사용하여 강성행렬과 부재내력의 계산이 근사적으로 수행되므로 유연도법에 비해 정확도가 낮은 단점이 있다. 종래의 유연도법에서는 변위형상 함수를 사용하지 않고 평형방정식을 만족하는 단면력-절점력 관계를 사용하여 단면력을 산정하므로 요소 내의 모든 단면에서 평형방정식을 만족시킬 수 있다. 그러나 유연도법은 강성도법에 비해 요소상태의 결정이 용이하지 않은 단점이 있다. 본 연구에서는 이러한 강성도법과 유연도법의 장점을 활용하여 강-콘크리트 합성구조물의 비선형해석을 위한 새로운 화이버 유한요소 혼합법(mixed method)을 개발하였다. 제안된 방법은 하중제어를 통한 Newton 방법을 사용하고 수치해석적으로 효과적이고 수렴성이 우수한 증분할선탄성계수법에 기반을 두고 있다. 또한 제안된 방법을 사용하여 강-콘크리트 합성구조물을 해석하였고 그 결과를 상용프로그램인 ABAQUS와 비교하였다. 그 결과 제안된 방법은 강-콘크리트 합성구조물의 비선형 거동을 정확하게 평가하였고 경제성이 매우 우수한 방법으로 입증되었다.

비정형 데이터를 이용한 화학물질 사고 대응 체계 정보속성 비교 분석 : 화학사고 예방, 대비 및 대응을 위한 OECD 지침서를 중심으로 (Comparative analysis of informationattributes inchemical accident response systems through Unstructured Data: Spotlighting on the OECD Guidelines for Chemical Accident Prevention, Preparedness, and Response)

  • 김용진;도충현
    • 지능정보연구
    • /
    • 제29권4호
    • /
    • pp.91-110
    • /
    • 2023
  • 화학물질 사고는 신속한 대응 및 복구가 어렵고, 환경오염과 인명피해가 동반된다는 점에서 매뉴얼의 중요성이 점차 주목받고 있으며, OECD에서는 화학사고 예방, 대비 및 대응을 위한 OECD 지침서(이하 OECD 지침서)를 2023년 6월 개정하였다. 또한, 기존 연구에서는 화학사고에 대한 인식 제고를 통해 법규, 규정, 매뉴얼 등 시스템적 대응이 필요하다는 점을 강조하고 있으나. 매뉴얼에 대한 정보속성 비교연구는 찾아보기 힘들었다. 이에, 본 연구는 기존 OECD 지침서(2판)와 개정된 OECD 지침서(3판)을 비교분석하여 OECD 지침서별 정보속성을 파악하고 시사점을 발굴하는 것을 목표로 하였다. 세부적으로는 어떤 단어가 중요해졌는지 파악하기 위해 TF-IDF(Term Frequency-Inverse Document Frequency) 분석을 적용하였으며, 유사하게 사용한 단어와 차별성있게 사용한 단어를 파악하기 위해 Word2Vec을 적용하였다. 최종적으로는 2X2 매트릭스를 제안하고, 각 사분면에 어떤 단어들이 있는지를 도출하여 OECD 지침서별 정보속성을 심층적으로 비교하였다. 본 연구는 연구자들이 정보속성을 파악하는데 도움이 되는 프레임워크를 제공하고자 하였으며, 실무적으로는 국내 화학관련 정부부처 및 기업의 표준메뉴얼 개정에 참고할 수 있을 것으로 보인다.

해양성 발광박테리아를 이용한 해양환경 독성평가 시험법 개발: N-Tox test (Development of Marine Toxicity Standard Method for Marine Luminescent Bacteria: Introduction of N-Tox test)

  • 이규태;박경수;김평중
    • 한국해양학회지:바다
    • /
    • 제13권2호
    • /
    • pp.156-163
    • /
    • 2008
  • 해양 기원의 발광박테리아 Vibrio fischeri를 이용한 발광박테리아 독성시험법은 1980년대 초반에 소개된 이후 많은 연구자들에 의해 이용되어오다 1998년 국제공인시험법으로 등재되어 지금은 전 세계적으로 이용되고 있다. 이 시험법은 테스트하고자하는 화학물질이나 환경시료에 발광박테리아를 30분간 노출시킨 후 나타나는 발광량 감소의 정도로서 독성 유무나 강도를 평가하는 방법으로서 신속성, 정밀성, 민감성, 경제성이 뛰어나다는 평가를 받고 있으며, 시험생물의 유지/배양없이 상용화된 키트 제품을 이용하여 독성 시험을 수행할 수 있다. 본 연구에서는 해양성 발광 박테리아 독성평가 키트로 판매되는 상용화제품(N-Tox)을 이용하여 수행된 결과를 제시하였다. 시험법 개발 및 표준화를 위한 시험항목으로는 시료 주입량, 발광량과 같은 기본 항목 테스트와 표준독성물질을 이용한 정도관리 테스트, 화학물질 및 현장시료에 대한 테스트가 포함되었다. 이 시험법은 자동화되어 누구나 쉽게 수행이 가능하면서도, 시험 결과 독성물질에 대한 용량-반응 관계가 확실하게 평가되고, 정밀도가 뛰어나며, 현장시료 독성평가에 이용할 수 있을 정도의 민감성을 지닌 것으로 입증되었다. 따라서 아직 생물검정이 보편화되지 않은 국내에서 편리하게 이용할 수 있는 표준독성시험방법의 하나로서 활용 가능하다고 사료된다.

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

$^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성 (Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$))

  • 김대연;신규설;오은정;김건재
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.101-104
    • /
    • 2010
  • 레이노 현상에 대한 검사 중 $^{201}Tl$을 이용한 검사에서 관류영상을 composite하여 혈액 풀 영상 과 국소 지연 영상 관찰 및 비교 시의 유용성에 대해서 평가하고자 한다. 2008년 2월부터 2009년 8월까지 레이노 현상을 호소로 경희대학교 동서 신의학병원 혈관외과를 찾은 29명을 대상으로 시행하였다. 방사성 동위원소는 $^{201}Tl$ 111 Mbq (3 mCi)를 검사부위 반대편 팔과 다리의 대각선 사지에 정맥 내 주사하였고, 최초 dynamic 관류 영상과 혈액 풀 영상 그리고 국소지연 영상을 저에너지 고해상도 조준기를 장착한 감마카메라를 이용하여 검사하였다. 보고자 하는 손 또는 발에 대한 관심영역(ROI : Region of Interest)은 관류영상을 composite한 영상과 혈액 풀 영상, 국소 지연 영상 순으로 양측을 동시 분석하였고 대응표본 T 검정(SPSS v12.0)을 이용하여 p-value를 측정하여 데이터의 상관관계를 확인하였다. 분석대상 29명의 레이노 환자(positive)에서 분석된 관류 composite 영상, 혈액 풀 영상, 국소 지연 영상에서 나타난 count ratio(Rt./Lt.)의 평균은 $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$이었다. 이를 바탕으로 혈액 풀 영상과 국소 지연 영상의 대응표본 T-검정결과 p<0.029를 만족했고, 또한 관류 composite 영상에 대한 혈액 풀 영상(p<0.038)과 국소 지연 영상 (p<0.016)이 각각 차이가 없음을 알 수 있었다. $^{201}Tl$을 이용한 Raynaud scan에서 관류 영상을 composite함으로써 혈액 풀 영상과 국소 지연 영상을 비교 평가하는데 도움을 줄 수 있었다. 또한 육안적 식별도 가능하여 향후 좀 더 깊이있는 연구가 진행된다면 보다 적절하고 유용한 진단적 정보를 얻을 수 있을 것으로 사료된다.

  • PDF

I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가 (Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT)

  • 김정열;김주연;남궁혁;강천구;김재삼
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.33-42
    • /
    • 2014
  • I-131의 주 에너지는 364 keV이고 이차적으로 637과 723 keV의 감마선을 방출한다. 이런 이유로 I-131 핵종을 이용한 검사에서는 일반적으로 고 에너지 조준기를 사용하고 있다. 반면 중 에너지 조준기는 과도한 격벽 투과의 영향 때문에 사용이 권고되지 않지만 I-131의 낮은 선량에 대해 계수율의 민감도를 향상시키기 위해 중 에너지 조준기를 사용하기도 한다. 이에 본 연구에서는 I-131 SPECT/CT에서 고 에너지와 중 에너지 조준기를 사용하여 조준기 선택에 대한 영상의 영향을 평가하고자 한다. I-131 점 선원과 NEMA NU-2 IQ phantom을 이용하여 Siemens symbia T16 SPECT/CT 장비로 중 에너지 조준기와 고 에너지 조준기를 사용하였다. 영상획득은 단일 에너지 창과 삼중 에너지 창으로 각각 적용하여 영상을 획득하였고, 재구성방법은 반복재구성 기법인 Flash 3D를 이용하여 CTAC, Scatter correction 적용 유무와 Iteration과 subset의 횟수를 변경하여 획득된 영상을 재구성하였다. 획득된 영상을 분석하여 두 조준기의 민감도와 대조도 그리고 잡음을 비교 평가하였다. 민감도는 중 에너지 조준기가 고 에너지 조준기보다 높게 나타났다(중 에너지 조준기: 188.18 cps/MBq, 고 에너지 조준기: 46.31 cps/MBq). 대조도는 삼중 에너지 창과 고 에너지 조준기를 사용하고 CTAC를 적용하여 16 subset 8 iteration을 적용한 재구성영상에서 가장 높은 대조도를 나타냈고(TCQI=190.64), 동일한 조건에서 중 에너지 조준기를 사용하였을 경우는 고 에너지 조준기에 비해 낮은 대조도를 나타냈다(TCQI=66.05). 잡음평가에서는 고 에너지 조준기보다 중 에너지 조준기에서 높게 나타났다 (P<0.001). 적절한 조준기의 선택은 영상의 질에 있어 중요한 사항이다. 본 연구를 통해 고 에너지 감마선을 방출하는 I-131 검사에서는 일반적으로 사용되고 있는 고 에너지 조준기를 사용하는 것이 영상의 질에 있어 가장 권고되는 바이다. 하지만 에너지 창, 매트릭스 크기, 반복 재구성 조건(subset과 iteration 수) 그리고 CTAC 및 scatter correction 여부등과 같은 조건들을 적절히 적용한다면 낮은 선량의 낮은 민감도를 갖는 조건에서는 중 에너지 조준기를 사용할 수 있을 것으로 사료된다.

  • PDF

사례기반추론과 텍스트마이닝 기법을 활용한 KTX 차량고장 지능형 조치지원시스템 연구 (An Intelligence Support System Research on KTX Rolling Stock Failure Using Case-based Reasoning and Text Mining)

  • 이형일;김종우
    • 지능정보연구
    • /
    • 제26권1호
    • /
    • pp.47-73
    • /
    • 2020
  • KTX 차량은 수많은 기계, 전기 장치 및 부품들로 구성되어 있는 하나의 시스템으로 차량의 유지보수에는 상당히 많은 전문성과 유지보수 작업자들의 경험을 필요로 한다. 차량 고장발생 시 유지보수자의 지식과 경험에 따라 문제 해결의 시간과 작업의 질적 차이가 발생하며 그에 따른 차량의 가용율이 달라진다. 일반적으로 문제해결은 고장 매뉴얼을 기반으로 하지만 경험이 많고 능숙한 전문가의 경우는 이와 더불어 개인의 노하우를 접목하여 신속하게 진단하고 조치를 취한다. 이러한 지식은 암묵지 형태로 존재하기 때문에 후임자에게 완전히 전수되기 어려우며, 이를 위해 사례기반의 철도차량 전문가시스템을 개발하여 데이터화된 지식으로 바꾸려고 하는 연구들이 있어왔다. 하지만, 간선에 가장 많이 투입되고 있는 KTX 차량에 대한 연구나 텍스트의 특징을 추출하여 유사사례를 검색하는 시스템 개발은 아직 미비하다. 따라서, 본 연구에서는 이러한 차량 유지보수 전문가들의 노하우를 통해 수행된 고장들에 대한 진단과 조치 이력을 문제 해결의 사례로 활용하여 새롭게 발생하는 고장에 대한 조치가이드를 제공하는 지능형 조치지원시스템을 제안하고자 한다. 이를 위하여, 2015년부터 2017년동안 생성된 차량고장 데이터를 수집하여 사례베이스를 구축하였고, 차원축소 기법인 비음수 행렬 인수분해(NMF), 잠재의미분석(LSA), Doc2Vec을 통해 고장의 특징을 추출하여 벡터 간의 코사인 거리를 측정하는 방식으로 유사 사례를 검색하였으며, 위의 알고리즘에 의해 제안된 조치내역들 간 성능을 비교하였다. 분석결과, 고장 내역의 키워드가 적은 경우의 유사 사례 검색과 조치 제안은 코사인 유사도를 직접 적용하는 경우에도 좋은 성능을 낸다는 것을 알 수 있었고 차원 축소 기법들의 성능 비교를 통해 문맥적 의미를 보존하는 차원 축소 방식 중 Doc2Vec을 적용하는 것이 가장 좋은 성능을 나타낸다는 것을 알 수 있었다. 텍스트 마이닝 기술은 여러 분야에서 활용을 위한 연구들이 이루어지고 있는 추세이나, 본 연구에서 활용하고자 하는 분야처럼 전문적인 용어들이 다수이고 데이터에 대한 접근이 제한적인 환경에서 이러한 텍스트 데이터를 활용한 연구는 아직 부족한 실정이다. 본 연구는 이러한 관점에서 키워드 기반의 사례 검색을 보완하고자 텍스트 마이닝 기법을 접목하여 고장의 특징을 추출하는 방식으로 사례를 검색해 조치를 제안하는 지능형 진단시스템을 제시하였다는 데에 의의가 있다. 이를 통해 현장에서 바로 사용 가능한 진단시스템을 단계적으로 개발하는데 기초자료로써 시사점을 제공할 수 있을 것으로 기대한다.