• Title/Summary/Keyword: comparison fuction

Search Result 11, Processing Time 0.027 seconds

A Review on the Grid-Connected Technology of the Distributed Energy Resources (분산형전원의 계통연계기술 리뷰)

  • Lee, Kyungsoo
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.371-372
    • /
    • 2014
  • This review focuses on grid-connected technology for distributed energy resources(DER). The grid-connected technology is categorized into three classifications: 1) protection function; 2) power quality improvement function; 3) grid stabilization fuction. Grid codes comparison of Japan, USA, EU and Korea is also described in the paper.

  • PDF

Finite Element Analysis in Finite Length Bar under Constant Amplitude Loading (일정진폭하중을 받는 유한 길이 봉의 유한요소해석)

  • Hwang, Eun-Ha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.525-533
    • /
    • 2010
  • Direct time integration method such as Newmark method is numerically performed under the assumption that continuous load function such as constant amplitude load can be treated as a discontinuous load fuction. It is due that the load can be treated as a constant value at the given time period regardless of variation of load at the time increment interval. It means the numerical results should be accompanied by the error due to approximation of load fuction. In contrast, the load function is calculated by convolution integral for the given time interval at finite element equation based on Gurtin's variation equation. Therefore. precise numerical results can be obtained by Gurtin's method because of convolution integral for the continuous load fuction curve even at the variation of load function in the given time interval. In this study, we prove that Gurtin's method can be more suitable than Newmark method in the problem of constant amplitude loading, using the numerical results for the free end of the one-dimensional rod. This study also shows that Gurtin's method is more effective in constant amplitude loading than in constant loading. The accuracy and the validity are verified by comparison between the results of in-house FORTRAN code and ADINA, a commercial software supporting Newmark method.

Analytical Solution of Non-dimensional Turbulent Kinetic Energy Distribution Function in the Turbulnet Wake behind a Submarine (잠수함 난류항적 기술을 위한 무차원 난류 에너지 분포함수 B(ξ) 예측)

  • Lee, YongChol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.31-36
    • /
    • 2015
  • To describe turbulent wake behind a submarine, it is very important to know turbulent kinetic energy distributions in the wake. To get the distribution is to solve the turbulent kinetic energy equation, and to solve the equation, it is needed both information of ${\lambda}$ and ${\sigma}$ which define physical characteristics of the wake. This paper gives analytical solution of the equation, which is driven from $8^{th}$ order polynomial fitting, as a function of given ${\lambda}$, even though there is no information of ${\sigma}$. In comparison between numerical solution(i.e. exact solution) and analytical solution, the relative errors between them are less than to 5% in the range of 0 < ${\xi}$ < 0.95 in most given ${\lambda}$.

A Study on the Strength Properties of Self-Compacting Concrete Utilizing Waste Concrete Podwer (폐콘크리트 미분말을 활용한 자기충전 콘크리트의 강도특성에 관한 연구)

  • Choi, Yun-Wang;Moon, Dae-Joong;Kim, Sung-Su;Kim, Ki-Hyung;Moon, Han-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.489-492
    • /
    • 2004
  • Compressive strength of self-compacting concrete with waste concrete powder(SCCWCP) linearly decreased as the containing ratio of WCP increas. When granulated blast furnace slag(SG) was contained for improving the rheological properties of SCCWCP, compressive strength of concrete with $15\%$ SG and $15\%$ WCP was increased in comparison with that of concrete with $30\%$ WCP. Splitting tensile strength of SCCWCP higher increased than that of CEB-FIP at same compressive strength. Relationship between compressive strength and elastic modulus of SCCWCP indicated a similar function with CEB-FIP fuction.

  • PDF

A Study on the Modeling and Control of a Flexible One-Link Manipulator Moving in a Vertical Plane (수직면에서 회전운동 하는 단일 탄성링크를 가지는 매니퓰레이터의 모델링과 제어에 관한 연구)

  • Kim, Jongdae;Oh, Seokhyung;Kim, Kiho;Oh, Chaeyoun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.11
    • /
    • pp.132-142
    • /
    • 1996
  • This paper presents a technique to model and control a manipulator which has a flexible link and moves in a vertical plane. The flexible link is modeled as an Euler-Bernoulli Beam. Elastic deformation of the flexible link is represented using the assumed modes method. A comparison function which satisfies all geometric and natural boundary conditions of a cantilever beam with an end mass is used as an assumed mode shape. Lagrange's equation is utilized for the development of a discretized model. This paper presents a simple technique to improve the correctness of the developed model. The final model including the shortening effect due to elastic deformation correlates very well with experimental results. The free body motion simulation shows that two assumed modes for the representation of the elastic deformation is proper in terms of the model size and correctness. A control algorithm is developed using PID control technique. The proportional, integral and derivative control gains are determined based on dominant pole placement method with a rigid one-link manipulator. A position control simulation shows that the control algorithm can be used to control the position and residual oscillation of the flexible one-link manipulator effectively.

  • PDF

Sensorless Vector Control for IM Adaptive Sliding Mode Controller (유도전동기 센서리스 벡터제어를 위한 적응슬라이딩모드 제어기)

  • Kim, Young-Choon;Cho, Moon-Taek;Joo, Hae-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5143-5149
    • /
    • 2011
  • In this paper, using the adaptive sliding mode observer for speed sensorless vector control is proposed. Adaptive sliding mode observer of the motor stator coordinate system using the voltage equations of the rotor flux components are observed. Motor speed was obtained by the Lyapunov function is estimated by the relationship further. In order to establish such a control scheme based on the way conventional PI controller and sliding mode observer annexing characteristics of the system through simulation and experiment were compared. According to analysis by comparison with the usefulness of the system was confirmed.

Preparation of Ampholyte Grafted Hollow-fiber Membrane and Its Adsorption Characteristic on Metallic Ions (양성전해질 고정막의 제조 및 그것의 금속이온 흡착 특성)

  • Choi, Hyuk-Jun;Park, Sang-Jin;Kim, Min
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.151-158
    • /
    • 2010
  • This paper presents the synthesis of ampholyte immobilized hollow-fiber membranes and adsorption characteristic of metallic ions. This is prepared by radiation induced grafting polymerization of an epoxy group containing Glycidyl methacrylate (GMA) onto an existing polyethylene porous hollow-fiber membrane. Ampholyte ion-exchanged alkalic group, $-NH_2$ (amine function) of Taurine (TAU) is reacted with glycidyl of GMA for the synthesis of stable membrane. However, Sodium sulfite (SS) membrane is also prepared by making chemical bonds with GMA of porous hollow-fiber membrane for the comparison of adsorption characteristic of metallic ions. These are called as TAU and SS membranes, respectively. It is shown that TAU membrane shows a steady flux, 0.9 m/h regardless of the density of TAU, while the flux of SS membrane decreases rapidly as the density of $SO_3H$ group increases. SS membrane showed a negligible flux. TAU membrane with the density 0.8 mmol/g shows the amount of metallic ions adsorbed in the following order, Cu > Cd > Mg > Sb > Pb. In general, TAU membrane with high density and reaction time showed the high amount of metallic ions adsorbed and flux.

Back Analysis of Unsaturated Hydraulic Conductivities for Transient Water Release and Imbibitions Measurement (부정류 유출 및 흡입시험에 대한 불포화 투수계수의 역해석)

  • Oh, Seboong;Kim, Do-Hyung;Song, Young-Sug
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.3
    • /
    • pp.5-12
    • /
    • 2018
  • Tests for transient water release and imbibitions measurement were conducted to estimate the unsaturated hydraulic conductivities by using back analysis. By using transient hydraulic characteristics, both the soil water retention curve and hydraulic conductivity fuction can be evaluated effectively and accurately. In this study the experiment for three samples were conducted accurately to measure the change of water content with time for various steps of matric suction. The back analysis calculated the amount of transient flow reliably in comparison with the experimental results. In the soil water retention curve there was no significant difference between the result of back analysis and that of experiment. The hydraulic conductivity function from back analysis was compared with the theoretical relation based on retention curve but they showed much difference. However, the unsaturated hydraulic behavior obtained by the combination of experimental and analytical techniques are considered to agree with the actual behavior.

Study of 25-Hydroxyvitamin D3 concentration according to the Hepatitis B virus (Hepatitis B virus에 따른 25-Hydroxyvitamin D3 농도 영향 연구)

  • Kim, Jean-Soo;Lee, Dong-Yeop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2743-2748
    • /
    • 2013
  • The vitamin gets through food and the sun. But there is case that density alters by certain factor in vitamin. So this research analyzed effect of the liver function factor and change of $25OH-VIT.D_3$ density. Research target is a person who undergo health medical examination in the certain university hospital medical examination center from August, 2012 to December, 2012. Comparison classified to experiment group and control group. As a result, variable that influence in $25OH-VIT.D_3$ density showed by age and B type inflammation of the liver titer. Specially, B type inflammation of the liver titer displayed reverse corelation ($R^2$=0.40). Therefore, inflammation of the liver carrier must manage liver fuction test and density of $25OH-VIT.D_3$.

A Performance Comparison of CM-MMA and RMMA Blind Equalization Algorithm in QAM Signal Transmission (QAM 신호 전송에서 CM-MMA와 RMMA 블라인드 등화 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • This paper compare the performance of CM-MMA (Constellation Matching-MMA) and RMMA (Region-based MMA) blind equalization algorithm for improve the QoS by minimizing the intersymbol interference that is occurred in nonlinear communication channel when transmitting the QAM signal. In the tap coefficient update for adaptive, CM-MMA use the error of nonconstant modulus signal adding the current MMA cost fuction and constellation matching error terms of sinusoidal power function, and the RMMA use the error by transfoms the nonconstant modulus signal of equalizer output constellation to 4-QAM constant modulus signal. They has different equalization performance by these error signal, it were compared in this paper by simulation, and performance index such as output signal constellation of equalizer, residual isi, maximum distortion, SER curves are applied for this. As a result of computer simulation, the RMMA has more better performance in the every performance index, convergence speed, residual value, noise robustness compared to CM-MMA.