• Title/Summary/Keyword: compare and analyze

Search Result 3,432, Processing Time 0.039 seconds

The efficacy of denture cleansing agents: A scanning electron microscopic study (수종 의치세정제의 세척 효과에 관한 주사전자현미경적 비교 연구)

  • Yun, Bo-Hyeok;Yun, Mi-Jung;Hur, Jung-Bo;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the cleansing performance of a distilled water, a diluted solution of sodium hypochlorite as a household bleaching cleanser and three alkaline peroxide cleansers in vivo plaque deposits by using scanning electron microscope. Materials and methods: Five individuals were selected from department of the prosthodontics in Pusan National University Hospital, and each of them was inserted with specimens for plaque accumulation in their temporary dentures for 48 hours. The specimens were removed and cleaned by each cleansing agents for 8 hours. Scanning electron micrographs were made from the specimens at a magnification of ${\times}2,000$. A panel of ten persons with a dental or paradental background, but not directly involved in the study, was selected to analyze the photomicrographs to determine which denture cleanser was more effective in removing plaque. Results: Diluted solution of sodium hypochlorite was the most effective at removing plaque following $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$ and distilled water in order. But there was no significant difference of cleansing efficacy between diluted solution of sodium hypochlorite and $Polident^{(R)}$, $Polident^{(R)}$ and $Cleadent^{(R)}e$, $Cleadent^{(R)}e$ and $Bonyplus^{(R)}$, respectively (P > .05). Alkaline peroxide cleansers by themselves cannot adequately remove accumulated plaque deposits, especially if the deposits are heavy. Corrosion could be seen on the surface of non-precious alloy specimens immersed in diluted solution of sodium hypochlorite. Conclusion: It is recommended to use of alkaline peroxide type cleansers with brushing whenever possible, since denture cleanliness is often poor due to the relative inefficiency of these cleansers.

MicroRNA Expression Profiling in Cell and Mouse Models of Fabry Disease to Identify Biomarkers for Fabry Disease Nephropathy (파브리병의 바이오마커 발굴을 위한 파브리 마우스와 세포모델에서의 microRNA 발현 분석)

  • Jung, Namhee;Park, Saeyoung;Jeon, Yeo Jin;Choi, Yoonyoung;Jung, Sung-Chul
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.127-137
    • /
    • 2015
  • Purpose: The main aim of this study was to compare and analyze expression profiles of microRNAs (miRNAs) to establish miRNA signature of Fabry nephropathy related epithelial mesenchymal transition (EMT). Methods: Expression profiles of miRNAs in kidney tissue samples and cell lines from normal and Fabry disease mouse model were examined by miRNA expression microarray analysis followed by quantitative real-time polymerase chain reaction analysis (qRT-PCR). Results: In the miRNA expression microarray analysis of Fabry mouse kidney tissues compared to wild type mouse, 5 and 3 miRNAs among 1,247 miRNAs examined were up- and down-regulated, respectively. Among them, miR-149-5p was down-regulated about 2-fold in Fabry kidney samples. The down-regulations of miR-149-5p were observed in kidney tissues of under 35 week-old-Fabry mice. However, this down-regulation was not observed in kidney tissues of 42 week-old Fabry mice. In SV40 MES 13 cells, mouse mesangial cells, treated with globotriaosylsphingosine (lyso-Gb3), miR-149-5p was also downregulated. The down-regulation of miR-149-5p induced up-regulation of its target genes related to EMT. Conclusion: The miRNA expression array and qRT-PCR results show that miR-149-5p expression was decreased in kidney tissues of Fabry mice compared to wild type mice under 35 weeks of age. Along with the observation of miR-149-5p expression in Fabry disease cell models, these results indicate that the down-regulated miR-149-5p were related to the biological response of mesangial cells to lyso-Gb3 and also have influence to the transcriptional up-regulation of its target genes. These results suggest miR-149-5p might play important roles in the Fabry nephropathy.

Simulation and model validation of Biomass Fast Pyrolysis in a fluidized bed reactor using CFD (전산유체역학(CFD)을 이용한 유동층반응기 내부의 목질계 바이오매스 급속 열분해 모델 비교 및 검증)

  • Ju, Young Min;Euh, Seung Hee;Oh, Kwang cheol;Lee, Kang Yol;Lee, Beom Goo;Kim, Dae Hyun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.200-210
    • /
    • 2015
  • The modeling for fast pyrolysis of biomass in fluidized bed reactor has been developed for accurate prediction of bio-oil and gas products and for yield improvement. The purpose of this study is to analyze and to compare the CFD(Computational Fluid Dynamics) simulation results with the experimental data from the CFD simulation results with the experimental data from the reference(Mellin et al., 2014) for gas products generated during fast pyrolysis of biomass in fluidized bed reactor. CFD(ANSYS FLUENT v.15.0) was used for the simulation. Complex pyrolysis reaction scheme of biomass subcomponents was applied for the simulation of pyrolysis reaction. This pyrolysis reaction scheme was included reaction of cellulose, hemicellulose, lignin in detail, gas products obtained from pyrolysis were mainly $CO_2$, CO, $CH_4$, $H_2$, $C_2H_4$. The deviation between the simulation results from this study and experimental data from the reference was calculated about 3.7%p, 4.6%p, 3.9%p for $CH_4$, $H_2$, $C_2H_4$ respectively, whereas 9.6%p and 6.7%p for $CO_2$ and CO which are relatively high. Through this study, it is possible to predict gas products accurately by using CFD simulation approach. Moreover, this modeling approach should be developed to predict fluidized bed reactor performance and other gas product yields.

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

The Optimal Turbo Coded V-BLAST Technique in the Adaptive Modulation System corresponding to each MIMO Scheme (적응 변조 시스템에서 각 MIMO 기법에 따른 최적의 터보 부호화된 V-BLAST 기법)

  • Lee, Kyung-Hwan;Ryoo, Sang-Jin;Choi, Kwang-Wook;You, Cheol-Woo;Hong, Dae-Ki;Kim, Dae-Jin;Hwang, In-Tae;Kim, Cheol-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.40-47
    • /
    • 2007
  • In this paper, we propose and analyze the Adaptive Modulation System with optimal Turbo Coded V-BLAST(Vertical-Bell-lab Layered Space-Time) technique that adopts the extrinsic information from MAP (Maximum A Posteriori) Decoder with Iterative Decoding as a priori probability in two decoding procedures of V-BLAST; the ordering and the slicing. Also, we consider and compare the Adaptive Modulation System using conventional Turbo Coded V-BLAST technique that is simply combined V-BLAST with Turbo Coding scheme and the Adaptive Modulation System using conventional Turbo Coded V-BLAST technique that is decoded by the ML (Maximum Likelihood) decoding algorithm. We observe a throughput performance and a complexity. As a result of a performance comparison of each system, it has been proved that the complexity of the proposed decoding algorithm is lower than that of the ML decoding algorithm but is higher than that of the conventional V-BLAST decoding algorithm. however, we can see that the proposed system achieves a better throughput performance than the conventional system in the whole SNR (Signal to Noise Ratio) range. And the result shows that the proposed system achieves a throughput performance close to the ML decoded system. Specifically, a simulation shows that the maximum throughput improvement in each MIMO scheme is respectively about 350 kbps, 460 kbps, and 740 kbps compared to the conventional system. It is suggested that the effect of the proposed decoding algorithm accordingly gets higher as the number of system antenna increases.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

The Direction of Physical Training for Actor in Post-Drama Era, "Empty" (포스트드라마 시대에 따른 배우의 몸 훈련의 방향성,'비우기(empty)')

  • Ra, Kyung-Min
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.77-90
    • /
    • 2020
  • Today, the transition to the era of "post-drama" brought a change in the position of text, which was considered the center of the play, and the expansion of the role of actors. After entering the post-drama era, the actor no longer transforms himself into "delivering" the fixed meaning of text, but "producing" the valid meaning of "now, here" meeting the audience. In other words, actors in the post-drama era have expanded their roles as "performers" who can become the subject of narratives themselves and create various theatrical languages. Despite the expansion of the actor's role, verbal-centered actor training through text, which still forms the basis of acting education, does not satisfy the newly changing contemporary theatricality and creates a gap between education and the field. Therefore, the researcher argued that non-verbal-centered acting education needs to be discussed, and highlighted the actors' physical training on the "empty" side. The researchers first compare and analyze the characteristics of modern theater people's training methods from an "empty" perspective. Based on this, researchers about the meaning and direction of the training "empty". Furthermore, the study concludes with an emphasis on the direction of acting education in the post-drama era, which is free from language that can respond to stimuli and interact freely.

Analyzing the Performance of the South Korean Men's National Football Team Using Social Network Analysis: Focusing on the Manager Bento's Matches (사회연결망분석을 활용한 한국 남자축구대표팀 경기성과 분석: 벤투 감독 경기를 중심으로)

  • Yeonsik Jung;Eunkyung Kang;Sung-Byung Yang
    • Knowledge Management Research
    • /
    • v.24 no.2
    • /
    • pp.241-262
    • /
    • 2023
  • The phenomena and game records that occur in sports matches are being analyzed in the field of sports game analysis, utilizing advanced technologies and various scientific analysis methods. Among these methods, social network analysis is actively employed in analyzing pass networks. As football is a representative sport in which the game unfolds through player interactions, efforts are being made to provide new insights into the game using social network analysis, which were previously unattainable. Consequently, this study aims to analyze the changes in pass networks over time for a specific football team and compare them in different scenarios, including variations in the game's nature (Qatar World Cup games vs. A match games) and alterations in the opposing team (higher FIFA rankers vs. lower FIFA rankers). To elaborate, we selected ten matches from the games of the Korean national football team following Coach Bento's appointment, extracted network indicators for these matches, and applied four indicators (efficiency, cohesion, vulnerability, and activity/leadership) from a football team's performance evaluation model to the extracted data for analysis under different circumstances. The research findings revealed a significant increase in cohesion and a substantial decrease in vulnerability during the analysis of game performance over time. In the comparative analysis based on changes in the game's nature, Qatar World Cup matches exhibited superior performance across all aspects of the evaluation model compared to A matches. Lastly, in the comparative analysis considering the variations in the opposing team, matches against lower FIFA rankers displayed superior performance in all aspects of the evaluation model in comparison to matches against top FIFA rankers. We hope that the outcomes of this study can serve as essential foundational data for the selection of football team coaches and the development of game strategies, thereby contributing to the enhancement of the team's performance.

Statistical Analysis of Patients Referred to Pediatric Cardiology Clinic for Diagnosis of Heart Disease (심장질환의 진단을 위해 의뢰된 환아들에 대한 자료 분석)

  • Choi, Kwang-Hae;Lee, Young-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Background: Echocardiography is rapidly establishing itself as the primary diagnostic technique for investigation of children with heart diseases, and referrals are increasing to the pediatric cardiology clinic for investigation. However, because there is a lack of analyzed data on the patients referred to the pediatric cardiology clinics, we have proceeded to compare and analyze their characteristics to provide basic data base. Methods: From Oct. 1, 1998 to Jul. 10, 1999, total 443 cases referred to the pediatric cardiology clinic of Yeungnam University Hospital were studied retrospectively by medical records, chest X-ray, EKG and echocardiography, etc. Results: The results were as follows. 1. The proportion of male was 61.0%(261 cases) and that of female was 39.0%(67 cases). The ratio of male to female was 1.6:1. The proportion infants less than 1 year-old was 62.6% (26R cases) of all patients. 2. Cardiac murmur was present in 248 cases(57.9%), which was the most common case of referral ed to the pediatric cardiology clinic. The impression at referral was more congenital heart disease(70.6%) than acquired heart disease(17.8%) and arrhythmia01.6%). 3. The final diagnosis was as follows : congenital heart disease was present in 212 cases(49.5%), acquired heart disease, 59 cases(13.9%); arrhythmia. 13 cases(3.0%); normal heart. 144 cases(33.6%). Conclusion: Among the patients referred to pediatric cardiology clinic, 33.6%(144 cases) had normal hearts and why these patients were referred may be possibly due to more dependence on echocardiography than on auscultation instruction. Therefore, clinical and auscultatory skill should be emphasized to minimize dependence on expensive echocardiography for evaluation of pediatric heart disease.

  • PDF

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF