• Title/Summary/Keyword: compact mapping

Search Result 79, Processing Time 0.056 seconds

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

Construction and Operation of a 37-channel Hemispherical Magnetoencephalogram System (37채널 반구형 뇌자도 측정장치 제작 및 동작)

  • 이용호;김진목;권혁찬;김기웅;박용기;강찬석;이순걸
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.159-165
    • /
    • 2003
  • We developed a 37-channel magnetoencephalogram (MEG) measurement system based on low-noise superconducting quantum interference device (SQUID) magnetometets, and operated the system to measure MEG signals. By using double relaxation oscillation SQUIDs with high flux-4o-voltage transfers, the SQUID outputs could be measured directly by room temperature preamplifiers and compact readout circuits were used for SQUID operation. The average field noise level of the magnetometers is about 3 fT/√Hz in the white region, low enough for MEG measurements when operated inside a magnetically shielded room. The 37 magnetometers were distributed on a hemispherical surface haying a radius of 125 mm. In addition to the 37 sensing channels. 11 reference channels were installed to pickup external noise and to form software gradiometers. A low-noise liquid helium dewar was fabricated with a liquid capacity of 30 L and boil-off rate of 4 L/d. The signal processing software consists of digital filtering, software gradiometer, isofield mapping and source localization. By using the developed system, we measured auditory-evoked fields and localized the current dipoles, demonstrating the effectiveness of the system.

Single Image Super-resolution using Recursive Residual Architecture Via Dense Skip Connections (고밀도 스킵 연결을 통한 재귀 잔차 구조를 이용한 단일 이미지 초해상도 기법)

  • Chen, Jian;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.24 no.4
    • /
    • pp.633-642
    • /
    • 2019
  • Recently, the convolution neural network (CNN) model at a single image super-resolution (SISR) have been very successful. The residual learning method can improve training stability and network performance in CNN. In this paper, we propose a SISR using recursive residual network architecture by introducing dense skip connections for learning nonlinear mapping from low-resolution input image to high-resolution target image. The proposed SISR method adopts a method of the recursive residual learning to mitigate the difficulty of the deep network training and remove unnecessary modules for easier to optimize in CNN layers because of the concise and compact recursive network via dense skip connection method. The proposed method not only alleviates the vanishing-gradient problem of a very deep network, but also get the outstanding performance with low complexity of neural network, which allows the neural network to perform training, thereby exhibiting improved performance of SISR method.

Analysis and modeling of thermal resistance of multi fin/finger FinFETs (멀티 핀/핑거 FinFET 트랜지스터의 열 저항 해석과 모델링)

  • Jang, MoonYong;Kim, SoYoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.39-48
    • /
    • 2016
  • In this paper, we propose thermal resistance compact model of FinFET structure that has hexagon shaped source/drain. The heating effect and thermal properties were increased by reduced size of the device, and thermal resistance is an important factor to analyze the effect and the properties. The heat source and each contact that is moved heat out were set up in transistor, and domain is divided by the heat source and the four parts of contacts : source, drain, gate, substrate. Each contact thermal resistance model is subdivided as a easily interpretable structure by analyzing the temperature and heat flow of the TCAD simulation results. The domains are modeled based on an integration or conformal mapping method through the structure parameters according to its structure. First modeled by analyzing the thermal resistance to a single fin, and applying the change in the parameter of the channel increases to improve the accuracy of the thermal resistance model of the multi-fin/ finger. The proposed thermal resistance model was compared to the thermal resistance by analyzing results of the 3D Technology CAD simulations, and the proposed total thermal resistance model has an error of 3 % less in single and multi-finl. The proposed thermal resistance model can predict the thermal resistance due to the increase of the fin / finger, and the circuit characteristics can be improved by calculating the self-heating effect and thermal characterization.

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.6
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

Accuracy of Parcel Boundary Demarcation in Agricultural Area Using UAV-Photogrammetry (무인 항공사진측량에 의한 농경지 필지 경계설정 정확도)

  • Sung, Sang Min;Lee, Jae One
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • In recent years, UAV Photogrammetry based on an ultra-light UAS(Unmanned Aerial System) installed with a low-cost compact navigation device and a camera has attracted great attention through fast and accurate acquirement of geo-spatial data. In particular, UAV Photogrammetry do gradually replace the traditional aerial photogrammetry because it is able to produce DEMs(Digital Elevation Models) and Orthophotos rapidly owing to large amounts of high resolution image collection by a low-cost camera and image processing software combined with computer vision technique. With these advantages, UAV-Photogrammetry has therefore been applying to a large scale mapping and cadastral surveying that require accurate position information. This paper presents experimental results of an accuracy performance test with images of 4cm GSD from a fixed wing UAS to demarcate parcel boundaries in agricultural area. Consequently, the accuracy of boundary point extracted from UAS orthoimage has shown less than 8cm compared with that of terrestrial cadastral surveying. This means that UAV images satisfy the tolerance limit of distance error in cadastral surveying for the scale of 1: 500. And also, the area deviation is negligible small, about 0.2%(3.3m2), against true area of 1,969m2 by cadastral surveying. UAV-Photogrammetry is therefore as a promising technology to demarcate parcel boundaries.

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF