• Title/Summary/Keyword: common zero

Search Result 238, Processing Time 0.028 seconds

A Comparative Assessment of Hydrogen Facility Installation for Net-Zero Energy District Planning (제로에너지단지의 적정 수소 활용 규모 및 운용방식에 관한 연구)

  • Junoh Kim;Chulhee Kim;Soyeon Chu
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.1-12
    • /
    • 2023
  • This study aims to evaluate the optimal size of the hydrogen facility to be installed in a zero-energy district in terms of load matching and facility efficiency. A mismatch between energy generation and consumption is a common occurrence in zero-energy districts. This mismatch adversely effects the energy grid. However, using an energy carrier such as hydrogen can solve this problem. To determine the optimal size of hydrogen fuel cells to be used on-site, simulation of hydrogen installation is required at both district-and building- levels. Each case had four operating schedules. Therefore, we evaluated eight scenarios in terms of load matching, heat loss, and facility operational efficiency. The results indicate that district-level installation of hydrogen facilities enables more efficient energy use. Additionally, based on the proposed model, we can calculate the optimal size of the hydrogen facility.

Performance Analysis and Comparison of Post-Fault PWM Rectifiers Using Various Space Vector Modulation Methods

  • Zhu, Chong;Zeng, Zhiyong;Zhao, Rongxiang
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2258-2271
    • /
    • 2016
  • In this paper, some crucial performance characteristics related to the operational reliability of the post-fault Pulse Width Modulated (PWM) rectifiers, such as line current harmonic distortion, Common Mode Voltage (CMV), and current stress on the capacitors, are fully investigated. The aforementioned performance characteristics of post-fault rectifiers are highly dependent on the utilized space vector modulation (SVM) schemes, which are also examined. Detailed analyses of the three most commonly used SVM schemes for post-fault PWM rectifiers are provided, revealing the major differences in terms of the zero vector synthesis approaches. To compare the performances of the three SVM schemes, the operating principles of a post-fault rectifier are presented with various SVM schemes. Using analytical and numerical methods in the time domain, the performances of the line current distortion, common mode voltage and capacitor current are evaluated and compared for each SVM scheme. The proposed analysis demonstrates that the zero vector synthesis approaches of the considered methods have significant impacts on the performance characteristics of rectifiers. In addition, the advantages and disadvantages of the proposed SVM schemes are discussed. The experimental results verify the effectiveness and validity of the proposed analysis.

The Reduction of Common-Mode Voltage in Matrix Converter without Using Zero Space Vector (영상태 벡터를 사용하지 않는 매트릭스 컨버터의 공통모드 전압 저감에 관한 연구)

  • Nguyen, Minh-Hoang;Lee, Hong-Hee;Jung, Eui-Heon;Chun, Tae-Won;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.638-642
    • /
    • 2005
  • This paper proposes a modified space-vector pulse width modulation (PWM) strategy which can restrict the common-mode voltage for three-phase to three-phase matrix converter and still keep sinusoidal input and output waveforms and unity power factor at the input side. The proposed control method has been developed based on contributing the appropriate space vectors instead of using zero space vectors. The advantages of this proposed method is to reduce the peak value of common-mode voltage to 42% beside the lower high harmonic components as compared to the conventional SVM method. Hence, the new table is also presented with the new space vector rearrangement. Furthermore, the voltage transfer ratio is unaffected by the proposed method. A simulation of the overall system has been carried out to validate the advantages of the proposed method.

  • PDF

The ISO/TS16949 the research regarding the application instance of the development technique for a APQP zero defect attainment (ISO/TS16949 APQP Zero Defect 달성을 위한 개발기법의 적용사례에 관한 연구)

  • Moon, Chan-Oh
    • Management & Information Systems Review
    • /
    • v.22
    • /
    • pp.211-229
    • /
    • 2007
  • The ISO/TS16949 APQP goal of defect prevention and decrease of spread waste, is the customer satisfaction which leads a continuous improvement and profit creation. The quality expense where the most is caused by but with increase of production initial quality problem occurrence is increasing to is actuality. Like this confirmation amendment. with the problem which is forecast in the place development at the initial stage which it does completeness it does not confront not to be able, production phase to be imminent, the problem accumulates and it talks the development shedding of which occurs. In opposition, prediction confrontation. is forecast in development early stage to and it is a structure which does not occur a problem to production early stage. Like this development is a possibility of accomplishing competitive company from production phase. Which attains an goal of, chance cause it leads a APQP activity (common cause) with special cause prevention & detection the connection characteristic of the focus technique against a interaction is important. And the customer requirement satisfaction and must convert a APQP goal of attainment at the key characteristics action step. (1) The Prevention - with Design FMEA application prevention of the present design management/detection, (2) the Detection (prevention/detection) - with Process FMEA application prevention of the present process control/detection, (3) Special Cause - statistical process control (SPC) 4M cause spread removal, (4) Common Cause - statistical process control (SPC) the nothing zero defect which leads the continuous improvement back of spread with application it will be able to attain with application.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240 (DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법)

  • Park Hyun Seok;Park Kyu Hyun;Kim Lee Hun;Han Sung Yong;Won Chung Yuen;Kim Young Real
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF

Analysis of residential natural gas consumption distribution function in Korea - a mixture model

  • Kim, Ho-Young;Lim, Seul-Ye;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.36-41
    • /
    • 2014
  • The world's overall need for natural gas (NG) has been growing up fast, especially in the residential sector. The better the estimation of residential NG consumption (RNGC) distribution, the better decision-making for a residential NG policy such as pricing, demand estimation, management options and so on. Approximating the distribution of RNGC is complicated by zero observations in the sample. To deal with the zero observations by allowing a point mass at zero, a mixture model of RNGC distributions is proposed and applied. The RNGC distribution is specified as a mixture of two distributions, one with a point mass at zero and the other with full support on the positive half of the real line. The model is empirically verified for household RNGC survey data collected in Korea. The mixture model can easily capture the common bimodality feature of the RNGC distribution. In addition, when covariates were added to the model, it was found that the probability that a household has non-expenditure significantly varies with some variables. Finally, the goodness-of-fit test suggests that the data are well represented by the mixture model.

Weighted zero-inflated Poisson mixed model with an application to Medicaid utilization data

  • Lee, Sang Mee;Karrison, Theodore;Nocon, Robert S.;Huang, Elbert
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.2
    • /
    • pp.173-184
    • /
    • 2018
  • In medical or public health research, it is common to encounter clustered or longitudinal count data that exhibit excess zeros. For example, health care utilization data often have a multi-modal distribution with excess zeroes as well as a multilevel structure where patients are nested within physicians and hospitals. To analyze this type of data, zero-inflated count models with mixed effects have been developed where a count response variable is assumed to be distributed as a mixture of a Poisson or negative binomial and a distribution with a point mass of zeros that include random effects. However, no study has considered a situation where data are also censored due to the finite nature of the observation period or follow-up. In this paper, we present a weighted version of zero-inflated Poisson model with random effects accounting for variable individual follow-up times. We suggested two different types of weight function. The performance of the proposed model is evaluated and compared to a standard zero-inflated mixed model through simulation studies. This approach is then applied to Medicaid data analysis.

Teaching Factorization in School Mathematics (학교수학에서 인수분해의 지도)

  • Choi, Sang-Ki;Lee, Jee-Hae
    • The Mathematical Education
    • /
    • v.48 no.1
    • /
    • pp.81-91
    • /
    • 2009
  • This paper focuses on two problems in the 10th grade mathematics, the rational zero theorem and the content(the integer divisor) of a polynomial Among 138 students participated in the problem solving, 58 of them (42 %) has used the rational zero theorem for the factorization of polynomials. However, 30 of 58 students (52 %) consider the rational zero theorem is a mathematical fake(false statement) and they only use it to get a correct answer. There are three different types in the textbooks in dealing with the content of a polynomial with integer coefficients. Computing the greatest common divisor of polynomials, some textbooks consider the content of polynomials, some do not and others suggest both methods. This also makes students confused. We suggests that a separate section of the rational zero theorem must be included in the text. As for the content of a polynomial, we consider the polynomials are contained in the polynomial ring over the rational numbers. So computing the gcd of polynomials, guide the students to give a monic(or primitive) polynomial as ail answer.

  • PDF

An Input-Powered High-Efficiency Interface Circuit with Zero Standby Power in Energy Harvesting Systems

  • Li, Yani;Zhu, Zhangming;Yang, Yintang;Zhang, Chaolin
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1131-1138
    • /
    • 2015
  • This study presents an input-powered high-efficiency interface circuit for energy harvesting systems, and introduces a zero standby power design to reduce power consumption significantly while removing the external power supply. This interface circuit is composed of two stages. The first stage voltage doubler uses a positive feedback control loop to improve considerably the conversion speed and efficiency, and boost the output voltage. The second stage active diode adopts a common-grid operational amplifier (op-amp) to remove the influence of offset voltage in the traditional comparator, which eliminates leakage current and broadens bandwidth with low power consumption. The system supplies itself with the harvested energy, which enables it to enter the zero standby mode near the zero crossing points of the input current. Thereafter, high system efficiency and stability are achieved, which saves power consumption. The validity and feasibility of this design is verified by the simulation results based on the 65 nm CMOS process. The minimum input voltage is down to 0.3 V, the maximum voltage efficiency is 99.6% with a DC output current of 75.6 μA, the maximum power efficiency is 98.2% with a DC output current of 40.4 μA, and the maximum output power is 60.48 μW. The power loss of the entire interface circuit is only 18.65 μW, among which, the op-amp consumes only 2.65 μW.

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.