• Title/Summary/Keyword: collection space

Search Result 523, Processing Time 0.031 seconds

A study on standards for college and university library building areas (대학도서관 시설기준에 관한 연구)

  • 손정표
    • Journal of Korean Library and Information Science Society
    • /
    • v.23
    • /
    • pp.363-404
    • /
    • 1995
  • This study is to set up a model of minimum and optimum standards for college and university library building areas in Korea. The results of this study are summarized as follows: 1. minimum standards(proposal) At first, Areas needed by factors of space component are as follows: User space --- 0.45 $m^{2}$ per student. Collection space --- 0.0107 $m^{2}$ per volume Staff space --- 10.1 $m^{2}$ per person Space attached to user, collection and staff space --- 5% of the sum of user, collection and staff areas(0.041 $m^{2}$ per student). Nonassignable space --- 25% of the sum of user, collection and staff areas (0.21 $m^{2}$ per student). Next, the formula to calculate the total area of the college and university library building is as follows: N = 0.45T $m^{2}$(a) + 0.0107V $m^{2}$(b) + 10.1S $m^{2}$(c) + 0.05(a+b+c) $m^{2}$, NS = 0.25N $m^{2}$. 2. Optimum standards(proposal) At first, Areas needed by factors of space component are as follows: User spae --- 0.64 $m^{2}$) per student. Collection space --- 0.01 $m^{2}$ per volume Staff space --- 9.7 $m^{2}$ per person Space attached to user, collection and staff space --- 5% of the sum of user, collection and staff areas(0.073 $m^{2}$ per student). Nonassignable space --- 25% of the sum of user, collection and staff areas(0.38 $m^{2}$ per student). Next, the formula to calculate the total area of the college and university library building is as follows: N = 0.64T $m^{2}$(a) + 0.01V $m^{2}$(b) + 9.7S $m^{2}$(c) + 0.05(a+b+c) $m^{2}$, NS = 0.25N $m^{2}$.

  • PDF

Performance Isolation of Shared Space for Virtualized SSD based Storage Systems

  • Kim, Sungho;Kwak, Jong Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.9
    • /
    • pp.1-8
    • /
    • 2019
  • In this paper, we propose a performance isolation of shared space for virtualized SSD based storage systems, to solve the weakness in a VSSD framework. The proposed scheme adopts a CFQ scheduler and a shared space-based FTL for the fairness and the performance isolation for multiple users on virtualized SSD based storage systems. Using the CFQ scheduler, we ensure SLOs for the storage systems such as a service time, a allocated space, and a IO latency for users on the virtualized storage systems. In addition, to improve a throughput and reduce a computational latency for garbage collection, a shared space-based FTL is adopted to maintain the information of SLOs for users and it manages shared spaces among the users. In our experiments, the proposal improved the throughput of garbage collection by 7.11%, on average, and reduced the computational latency for garbage collection by 9.63% on average, compared to the previous work.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

A relationship among types of museum space, number of visitors, and number of collections (박물관 공간구성이 방문객수와 소장품수에 대해 갖는 관계)

  • Kim, Jung Hyun;Shin, Hyung-Deok;Park, Ji Hyon
    • Korean Association of Arts Management
    • /
    • no.49
    • /
    • pp.65-86
    • /
    • 2019
  • This study investigated the relationship among type of museum space, number of visitors, and number of collections. Museum space has been sorted in various ways(e. g. Seo, 2008; Lee, 2008; Ambrose & Paine, 2012), but this study adopted Lord et al. (2012)'s typology, which has public/non-public and collection/non-collection space, considering that Korean museums' space fits their typology. Using 853 museum data our regression analyses show that public-collection space is positively related to the number of visitors is bigger, while non-public-collection space is positively related to the number of collections. This study has academic and practical implications by showing there are differential relationship among those physical museum characteristics and museum performance.

Environmental Measurements of Gallery and Storage Rooms of The New National Museum of Korea (용산 새 국립중앙박물관 수장고와 전시실 환경 관리 및 측정)

  • Lee, Sungeun;Roh, Hyunsook
    • Conservation Science in Museum
    • /
    • v.7
    • /
    • pp.75-87
    • /
    • 2006
  • The National Museum of Korea has striven for the stable preservation environment for its collection as it reopened in October 2005. The temperature and humidity, harmful gases in the collection storage space and the galleries were regularly measured to confirm whether the environment was stable for the collection; the material that could directly influence the collection such as showcases were tested in advance to select stable material. In addition, to prevent biological damage, whole collection was fumigated; insect monitoring traps have been regularly established to check the status of the collection storage space.

Partial Garbage Collection Technique for Improving Write Performance of Log-Structured File Systems (부분 가비지 컬렉션을 이용한 로그 구조 파일시스템의 쓰기 성능 개선)

  • Gwak, Hyunho;Shin, Dongkun
    • Journal of KIISE
    • /
    • v.41 no.12
    • /
    • pp.1026-1034
    • /
    • 2014
  • Recently, flash storages devices have become popular. Log-structured file systems (LFS) are suitable for flash storages since these can provide high write performance by only generating sequential writes to the flash device. However, LFS should perform garbage collections (GC) in order to reclaim obsolete space. Recently, a slack space recycling (SSR) technique was proposed to reduce the GC overhead. However, since SSR generates random writes, write performance can be negatively impacted if the random write performance is significantly lower than sequential write performance of the target device. This paper proposes a partial garbage collection technique that copies only a part of valid blocks in a victim segment in order to increase the size of the contiguous invalid space to be used by SSR. The experiments performed in this study show that the write performance in an SD card improves significantly as a result of the partial GC technique.

Effects of Electrohydrodynamic Flow and Turbulent Diffusion on Collection Efficiency of an Electrostatic Precipitator with Cavity Walls

  • Park, Seok-Joo;Park, Young-Ok;Kim, Sang-Soo;McMurry, Peter H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.97-103
    • /
    • 2001
  • The effects of the electrohydrodynamic (EHD) flow and turbulent diffusion on the collection efficiency of a model ESP composed of the plates with a cavity were studied through numerical computation. The electric field and ion space charge density were calculated by the Poisson equation of the electrical potential and the current continuity equation. The EHD flow field was solved by the continuity and momentum equations of the gas phase including the electrical body force induced by the movement of ions under the electric field. The RNG $k-{\varepsilon}$ model was used to analyze the turbulent flow. The particle concentration distribution was calculated from the convective diffusion equation of the particle phase. As the ion space charge increased, the particulate collection efficiency increased because the electrical potential increased over the entire domain in the ESP. The collection efficiency decreased and then increased, i.e. had a minimum value, as the EHD circulating flow became stronger when the electrical migration velocity of the charged particle was low. However, the collection efficiency decreased with the stronger EHD flow when the electrical migration of the particle was higher relatively. The collection efficiency of the model ESP increased as the turbulent diffusivity of the particle increased when the electrical migration velocity of the particle was low. However, the collection efficiency decreased for increasing the turbulent diffusivity when the electrical migration of the particle was higher relatively.

  • PDF

Case Study on Collection Saturation of Public Library (공공도서관 장서의 포화에 관한 사례 연구)

  • Kim, Hong-Ryul
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.3
    • /
    • pp.49-69
    • /
    • 2019
  • The purpose of this study is to measure the saturation of the collection in public library and to propose a solution to this problem. In order to conduct this study, one local government was selected to measure the collection saturation status of each library and to clarify the cause of collection saturation. Based on the research results derived from this study, the public library in Korea measures the degree of collection saturation and recognizes the seriousness of collection saturation, and suggests the task of identifying the cause of collection saturation and solving it.

Indoor Path Recognition Based on Wi-Fi Fingerprints

  • Donggyu Lee;Jaehyun Yoo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.91-100
    • /
    • 2023
  • The existing indoor localization method using Wi-Fi fingerprinting has a high collection cost and relatively low accuracy, thus requiring integrated correction of convergence with other technologies. This paper proposes a new method that significantly reduces collection costs compared to existing methods using Wi-Fi fingerprinting. Furthermore, it does not require labeling of data at collection and can estimate pedestrian travel paths even in large indoor spaces. The proposed pedestrian movement path estimation process is as follows. Data collection is accomplished by setting up a feature area near an indoor space intersection, moving through the set feature areas, and then collecting data without labels. The collected data are processed using Kernel Linear Discriminant Analysis (KLDA) and the valley point of the Euclidean distance value between two data is obtained within the feature space of the data. We build learning data by labeling data corresponding to valley points and some nearby data by feature area numbers, and labeling data between valley points and other valley points as path data between each corresponding feature area. Finally, for testing, data are collected randomly through indoor space, KLDA is applied as previous data to build test data, the K-Nearest Neighbor (K-NN) algorithm is applied, and the path of movement of test data is estimated by applying a correction algorithm to estimate only routes that can be reached from the most recently estimated location. The estimation results verified the accuracy by comparing the true paths in indoor space with those estimated by the proposed method and achieved approximately 90.8% and 81.4% accuracy in two experimental spaces, respectively.

Garbage Collection Synchronization Technique for Improving Tail Latency of Cloud Databases (클라우드 데이터베이스에서의 꼬리응답시간 감소를 위한 가비지 컬렉션 동기화 기법)

  • Han, Seungwook;Hahn, Sangwook Shane;Kim, Jihong
    • Journal of KIISE
    • /
    • v.44 no.8
    • /
    • pp.767-773
    • /
    • 2017
  • In a distributed system environment, such as a cloud database, the tail latency needs to be kept short to ensure uniform quality of service. In this paper, through experiments on a Cassandra database, we show that long tail latency is caused by a lack of memory space because the database cannot receive any request until free space is reclaimed by writing the buffered data to the storage device. We observed that, since the performance of the storage device determines the amount of time required for writing the buffered data, the performance degradation of Solid State Drive (SSD) due to garbage collection results in a longer tail latency. We propose a garbage collection synchronization technique, called SyncGC, that simultaneously performs garbage collection in the java virtual machine and in the garbage collection in SSD concurrently, thus hiding garbage collection overheads in the SSD. Our evaluations on real SSDs show that SyncGC reduces the tail latency of $99.9^{th}$ and, $99.9^{th}-percentile$ by 31% and 36%, respectively.