• 제목/요약/키워드: collection efficiency

검색결과 958건 처리시간 0.031초

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

접선유입식과 축상유입식 사이클론의 집진효율 비교 (Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구 (Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

저온플라즈마에 의한 배연 가스내의 미스트 처리기술 (The Technology of Mist Removal in Flue Gas by the Plasma of Impulse Streamer Corona)

  • 하상안;김일배;강신묵
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.69-76
    • /
    • 1999
  • This research was carried but to investigate the characteristics of mist removal with the change of operating conditions in the plasma reactor of impulse streamer corona based on the distribution of particle size measured by laser diffraction spectrometers. The operating conditions in this experiment were power of impulse streamer corona, gas velocity, collection time, and SOx/NOx concentration. The collection efficiency T(d) was estimated by distribution of particle size in the collection zone through the advanced model.

  • PDF

오일 미스트 포집을 위한 저전력 소비형 2단 전기집진기의 집진효율에 대한 연구 (A study on particle collection efficiency of a low power consumption two-stage electrostatic precipitator for oil mists collection)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.834-843
    • /
    • 2014
  • 본 연구에서는 마이크로 탄소 브러쉬 하전부와 평판형 금속 집진부로 구성된 저전력 소비형 2단형 전기집진기를 개발하였고, 특히 인체 위해성이 높은 $0.3{\mu}m$급의 미세한 오일 미스트에 대한 인가전압 및 소비전력별 집진효율 특성을 실험연구를 통해 고찰하였다. 하전부의 인가전압에 따른 단위 입자당 하전율과 입경별 집진효율을 측정함과 동시에 이론에 근거한 계산값과 비교해 보았으며, 9 주 동안의 장시간 운전을 통해 지속적으로 포집된 오일 미스트에 의한 전기집진기의 성능을 열유체역학적인 관점에서 변화를 조사하였다.

Experimental Study on the Enhancement of Particle Removal Efficiency in Spray Tower Scrubber Using Electrospray

  • Kim, Hyeok-Gyu;Kim, Hong-Jik;Lee, Myong-Hwa;Kim, Jong-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권2호
    • /
    • pp.89-95
    • /
    • 2014
  • There have been a lot of efforts to keep permissible emission standards and to reduce the amount of emitted air pollutants. There are several air pollution control equipments, however, wet scrubber is used to remove particulate matters and gaseous pollutants simultaneously, even if it has low collection efficiency in the particle size less than $5.0{\mu}m$. To overcome this problem, we introduced a spray tower scrubber with an electrospray system which a high voltage was indirectly applied. We found that collection efficiency of fine particles in the electrospray system was improved by increasing electrical field strength and the ratio of liquid-gas flow rate (from 41% to 84% for $0.3{\mu}m$ particles). In addition, a number of small droplets generated from an electrospray system led high collection efficiency, resulting from electrostatic attraction between droplets and particles and higher collision frequency. Therefore, we can conclude that the introduction of an electrospray system is quite effective to increase the particle removal efficiency of a spray tower scrubber.

원심력 효과를 고려한 실린더형 전기집진기의 특성 (Characteristics of Cylindrical Electrostatic Precipitator with Centrifugal Effect)

  • 이준;조용수;여석준
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.351-358
    • /
    • 2001
  • The main purpose of this study was to investigate the characteristics of cylindrical electrostatic precipitator with centrifugal effect in viewpoints of pressure drip and collection efficiency, experimentally. The experiment was carried out for the analysis of current-voltage, pressure drop and collection efficiency with various experimental parameters such as the applied voltage, inlet velocity, inlet size and inlet type(upper and bottom), etc. In the results, the pressure drops were estimated as 27~54, $34~63mmH_2O$ for inlet size $15mm{\tiems}30mm$ and $30mm{\tiems}60mm$, respectively. The collection effeciencies were shown over 90% with the small inlet size($15mm{\tiems}30mm$) for the applied voltage 40kV, inlet velocity(15~21m/s), and 51~89% with the large inlet size ($30mm{\tiems}60mm$). Moreover, in the applied voltage 0kV and inlet size $15mm{\tiems}30mm$, the collection efficiency induced by centrifugal force was represented as about 35% with inlet velocity 15 - 21m/s.

  • PDF

카본블랙류 미세입자 포집을 위한 유리섬유 필터백의 고분자 표면처리에 관한 연구 (A study on the Polymer surface treatment of GF-filter bag for collection of fine Particle like carbon black)

  • 이봉;최희락;문창권
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.55-59
    • /
    • 2008
  • In this paper, we have investigated on collection efficiency of fine particle of glass fiber-filter bag according to the surface treatment. The solution consisted of polytetrafluoroethylene(teflon), graphite powder, silicon resin and water was used as a basic surface treatment agent. Tensile strength of glass filter-bag increased with up to 3hrs and then decreased with surface treatment time. Tensile strength and initial modulus of the glass fiber-filter bag treated by iodine after basic surface treatment for 3hrs were lower than those of basic surface treatment for 3hrs, however collection efficiency and fracture strain were higher than those of basic surface treatment for 3hrs. Glass fiber-filter bag with lower initial modulus and more strain will be extend the durable period and the one treated by iodine after basic surface treatment 3or 3hrs is expected high collection efficiency of fine particle. This method makes it possible to manufacture glass fiber-filter bag of the optimum condition.

  • PDF

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가 (Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment)

  • 김학준;한방우;김용진
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.