• Title/Summary/Keyword: cold temperature dry

Search Result 165, Processing Time 0.053 seconds

Changes in Abscisic Acid, Carbohydrate, and Glucosinolate Metabolites in Kimchi Cabbage Treated with Glutamic Acid Foliar Application under Extremely Low Temperature Conditions (이상저온 시 글루탐산 엽면 처리에 의한 배추의 ABA, 탄수화물 및 Glucosinolate 대사체 변화)

  • Sim, Ha Seon;Jo, Jung Su;Woo, Ui Jeong;Moon, Yu Hyun;Lee, Tae Yeon;Lee, Hee Ju;Wi, Seung Hwan;Kim, Sung Kyeom
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.170-179
    • /
    • 2022
  • Glutamic acid is a precursor of essential amino acids that play an important role in plant growth and development. It is one of the biostimulants that reduce cold stress damage by stimulating biosynthetic pathways leading to cryoprotectants. This study evaluated the effects of glutamic acid foliar application on Kimchi cabbage under low-temperature stress. There were six treatments, combining three photo-/dark periods temperature levels (11/-1℃ extremely low, E; 16/4℃ moderately low, M; and 21/9℃ optimal, O) with and without glutamic acid foliar application (0 and 10 mg·L-1; Glu 0 and Glu 10). Glutamic acid foliar application was sprayed once 10 days after transplanting, and then temperature treatment immediately after glutamic acid foliar application was conducted for up to four days. After four days of treatment, abscisic acid (ABA), phaseic acid (PA), dihydrophaseic acid (DPA), and abscisic acid-glucose ester (ABA-GE) contents were higher with Glu 10 treatment than Glu 0 treatment in M treatment. Glucose content was highest in E with Glu 10 treatment (52.1 mg·100 g-1 dry weight), while fructose content was highest in O with Glu 0 treatment (134.6 mg·100 g-1 dry weight). The contents of glucolepiddin (GLP), glucobrassicin (GBS), 4-methoxyglucobrassicin (4MGBS), neoglucobrassicin (GNBS), and gluconasturtiin (GNS) were highest among all treatments in E with Glu 10 treatments (0.72, 2.05, 1.67, 9.40 and 0.85 µmol·g-1 dry weight). After two days of treatment, rapid changes in PA and DPA contents of E with Glu 10 treatments were confirmed, and several individual glucosinolate contents (GLP, GBS, 4MGBS, GNBS, and GNS) were significantly different depending on low temperature and glutamic acid treatment. In addition, the content of fructose was significantly lower than that of O treatment in E and M treatments after four days of treatment. Therefore, although the changes in PA, DPA, glucose, fructose, and individual glucosinolates according to low temperature and glutamic acid foliar treatment were shown. A clear correlation between low temperature and glutamic acid effects could not be evaluated. Results indicated that Brassica crops are cryophilic vegetables, do not react sensitively to low temperatures, and mostly have cold resistance.

Characteristics of Norovirus Food Poisoning Outbreaks in Korea over the Past Ten Years and the Relation with Climate Factors (우리나라에서 지난 10년간 노로바이러스 식중독 발생의 특징과 기후요소와의 관련성)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.622-629
    • /
    • 2019
  • Objectives: The occurrence of norovirus food poisoning in South Korea has been reported since 2003. This study was performed to investigate the characteristics of norovirus food poisoning outbreaks in Korea from 2006 to 2015 and to analyze the relationship between these outbreaks and climate factors. Methods: Data on norovirus food poisoning outbreaks were obtained from the Korea Ministry of Food and Drug Safety. Data on climate factors were obtained from the Korea Meteorological Administration. Frequency analysis and Pearson's correlation analysis were adopted for this study. Results: During the study period, norovirus was the greatest contributing factor of food poisoning outbreaks. Approximately half of the outbreaks of norovirus food poisoning occurred in winter. Average temperature, highest and lowest temperatures, precipitation, number of days with rainfall, and humidity all had a significant negative correlation with monthly number of outbreaks of norovirus food poisoning (p<0.05). Among these, the lowest and average temperature showed higher correlation coefficients. However, the sum of the outbreaks in spring and autumn was similar to that of winter, and more than one-third occurred in group meal-service settings, including school lunches. This was strongly assumed as the use of norovirus-contaminated groundwater for preparation of meals in some settings. Conclusion: The cold and dry of the winter season in Korea may assist the transmission of norovirus. Also, the use of groundwater in group meal service is suspected of inducing a larger scale of norovirus food poisoning. Both health authorities and community-based prevention and control measures are required to respond to these complex etiological outbreaks.

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Effects of low temperature and salicylic acid on chilling tolerance in cucumber seedlings

  • Jung, Sang-Duck;Jung, You-Jin;Kim, Tae-Yun;Hong, Jung-Hee
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2002.05b
    • /
    • pp.468-471
    • /
    • 2002
  • The present study was undertaken to Investigate the effects of low temperature and salicylic acid (SA) on chilling tolerance In acclimated and nonacclimated cucumber seedlings. Acclimation significantly affected survival and shoot dry weights. Injuries of acclimated seedlings at the third leaf stage were on the average smaller by half than those of the nonacclimated ones. Chilling caused a large increase in free proline levels, regardless of acclimation status. Exogenous treatment with SA resulted in improvement in growth and survival of acclimated, chilled seedlings, indicating SA and acclimation have common effects. Cycloheximide treatment In the presence of SA restored acclimation-induced chilling tolerance. An elevated proline level was observed in cold-treated and SA- treated plants and the level was more pronounced in the light than in the dark at chilled temperature, indicating that endogenous proline may play a role in chilling tolerance.

  • PDF

The Study of experiment on preventing frost damage at early age of mortar in low temperature using Reduction slag. (환원슬래그를 사용한 콘크리트의 내구성 평가에 관한 연구)

  • Min, Tae-Beom;Choi, Hyun-Kuk;Mun, Young-Bum;Kim, Hyeong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.150-151
    • /
    • 2016
  • In previous study, researchers studied development of early anti-freezing cement at low temperature (-5℃) using hydration characteristics of reduction slag. In this study, the durability of concrete using reduction slag was conducted. The experiment result, reduction slag makes high temperature and improves compressive strength due to quick setting. And then result of durability show that it is no problem. However, it is considered that further study is needed about high shrinkages which was indicated in dry shrinkage.

  • PDF

Effect of the Kind of Surface-Covered Curing Materials on the Temperature of Concrete in Hot Weather (서중환경에서 표면피복 양생재 종류가 콘크리트의 온도에 미치는 영향)

  • Lee, Je-Hyun;Kim, Min-Sang;Moon, Byeong-Yong;Lee, Sang-Un;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.173-174
    • /
    • 2017
  • Although the application period of hot weather concrete in our country is two months of July~August which is relatively short, many problems in various aspects such as generation of plastic/dry contraction cracks and cold joints can be caused unless proper quality control measures are established at this time. Therefore, this study compared the temperature history of the placed concrete by applying a mono white and aluminum-deposited bubble sheet developed with surface coating curing materials for surface exposure and summer to an actually constructed apartment slab. The analysis result showed that the mono white bubble sheet is the best method.

  • PDF

Design and Exergy Analysis for a Combined Cycle using LNG Cold/Hot Energy (액화천연가스 냉온열을 이용한 복합사이클의 설계 및 엑서지 해석)

  • Lee Geun Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.285-296
    • /
    • 2005
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a production ratio of solid $CO_2$. The present study shows that much reduction in both $CO_2$ compression power (only $35\%$ of power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency ($55.3\%$ at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a production ratio of solid $CO_2$ increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements (냉각탑 백연방지의 성능 향상에 관한 실험적 연구)

  • JEONG, SOON YOUNG;LEE, BYEONG CHEON;KIM, SUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

Study on Rice Growing Environment Against Cold Sea Wind in Eastern Coastal Area of Korean Peninsula (동해안 냉해풍지역의 벼 생육환경 연구)

  • Kim, Jeong-Il;Lee, Ji-Yoon;Park, Dong-Soo;Park, No-Bong;Kwon, Oh-Deog;Chang, Jae-Ki;Lee, Ji-Hun;Kim, Sang-Yeol;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • This study was conducted to analysis a major cause of rice yield reduction in 4 research points, 1, 2, 3, and 5km, from coastline in the East Sea. There were great changes of temperature in each research point, though the average temperature a day was no difference between each research point. Each temperature in 1, 2, and 3km research points was 8, 7, and $4^{\circ}C$ lower than in 5km when cold salty wind was generated due to cold pool. As it was close in coastline, its soil was abundant sand components, little silt and clay soil components and lacking in cation exchange capacity(CEC). And plant height became a smaller, heading date was delayed for 3~4 days, and dry weight was reduced. Also, it was to be down percent of fertile grain. As cultivation site was close in seaside, its decline was larger because of reduction of panicle number per hill. It was "Samdeogbyeo" that was variety adapted in cold salty wind, having yield potential more than 90% in 2km.

Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season (고온기 근권냉방방식에 따른 냉방효과와 토마토 생육)

  • 이재한;권준국;권오근;최영하;박동금
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.81-87
    • /
    • 2002
  • This study was conducted to investigate the cooling efficiency and growth of tomatoes by root zone cooling device using a pad-box and cultivated system. The structure of the root zone cooling system using a pad-box was four piece of pads bonded an the side and a fan set at the bottom. Cool wind was generated by the outside air which was punched at intervals of 10 cm along three rows. Cold wind flowed to the root zone in the culture medium. The root zone cooling efficiency of cold wind generation by using a pad-box flowing through a wet-pad was determined. Major characteristic of this cuttural system consist of bed filled with a perlite medium and a ventilation pipe using PVC. The cold wind generation by a pad box (CWP) was compared to that of cold wind generation by a radiator (CWR), cold water circulation using a XL-pipe (CWX) and the control (non-cooling). When the temperature of water supplied was 16.2-18.4$^{\circ}C$, temperatures in the medium were 20.5~23.2$^{\circ}C$ for CWP 22.7~24.2$^{\circ}C$ for CWR, 22.8~24.27$^{\circ}C$ for CWX and 23.1~-29.6$^{\circ}C$ for the control. The results show that the cold wind temperature using the pad-box was lower by 1~2$^{\circ}C$ than that of cold water circulation in the XL-pipe and lower by 5~6$^{\circ}C$ than that of the control. Growth such as leaf length, leaf width, fresh weight and dry weight, was greater in three root zone cooling methods than in the control. Root activity was higher in the rat zone cooling methods than in the control. However, there was no significant difference among root zone cooling methods.