• 제목/요약/키워드: closed range

검색결과 632건 처리시간 0.027초

ON THE CLOSED RANGE COMPOSITION AND WEIGHTED COMPOSITION OPERATORS

  • Keshavarzi, Hamzeh;Khani-Robati, Bahram
    • 대한수학회논문집
    • /
    • 제35권1호
    • /
    • pp.217-227
    • /
    • 2020
  • Let ψ be an analytic function on 𝔻, the unit disc in the complex plane, and φ be an analytic self-map of 𝔻. Let 𝓑 be a Banach space of functions analytic on 𝔻. The weighted composition operator Wφ,ψ on 𝓑 is defined as Wφ,ψf = ψf ◦ φ, and the composition operator Cφ defined by Cφf = f ◦ φ for f ∈ 𝓑. Consider α > -1 and 1 ≤ p < ∞. In this paper, we prove that if φ ∈ H(𝔻), then Cφ has closed range on any weighted Dirichlet space 𝒟α if and only if φ(𝔻) satisfies the reverse Carleson condition. Also, we investigate the closed rangeness of weighted composition operators on the weighted Bergman space Apα.

평행평판 도파관내 수평자기쌍극자에 대한 개선된 단순함수형태의 그린함수 (Improved closed-form Green's function for a horizontal magnetic dipole in a parallel-plate waveguide)

  • 이영순;권호상;조영기
    • 전자공학회논문지D
    • /
    • 제35D권5호
    • /
    • pp.24-32
    • /
    • 1998
  • Spatial green's functions for a horizontal magnetic dipole in a parallel-plate waveguide are expressed in an improved closed-form with two-level approximation of the spectral green's functions. The results evaluated by the present closed-from green's function with two-level approximation are compard with those obtained the previous closed-form green's function with one-level approximation. The present results are observed to be more acurate than the previous results over wide frequency range as well as whole spatial range. The combination of the present closed-form green's functions and the moment mehtod may help in analyzing the problem of EMP coupling through an aperture into a parallel-plat waveguide and the microstrip slot antenna with a reflector.

  • PDF

거리정보 기반 무선위치추정을 위한 혼합 폐쇄형 해 (Hybrid Closed-Form Solution for Wireless Localization with Range Measurements)

  • 조성윤
    • 제어로봇시스템학회논문지
    • /
    • 제19권7호
    • /
    • pp.633-639
    • /
    • 2013
  • Several estimation methods used in the range measurement based wireless localization area have individual problems. These problems may not occur according to certain application areas. However, these problems may give rise to serious problems in particular applications. In this paper, three methods, ILS (Iterative Least Squares), DS (Direct Solution), and DSRM (Difference of Squared Range Measurements) methods are considered. Problems that can occur in these methods are defined and a simple hybrid solution is presented to solve them. The ILS method is the most frequently used method in wireless localization and has local minimum problems and a large computational burden compared with closed-form solutions. The DS method requires less processing time than the ILS method. However, a solution for this method may include a complex number caused by the relations between the location of reference nodes and range measurement errors. In the near-field region of the complex solution, large estimation errors occur. In the DSRM method, large measurement errors occur when the mobile node is far from the reference nodes due to the combination of range measurement error and range data. This creates the problem of large localization errors. In this paper, these problems are defined and a hybrid localization method is presented to avoid them by integrating the DS and DSRM methods. The defined problems are confirmed and the performance of the presented method is verified by a Monte-Carlo simulation.

관절 함몰형 종골 골절에 대한 비관혈적 정복 및 경피적 내고정의 수술적 치료 결과 (The Result of Closed Reduction and Percutaneous Screw Fixation for Intra-articular Calcaneal Fracture of Joint Depression Type)

  • 김광열;박영일;임문섭;윤성환
    • 대한족부족관절학회지
    • /
    • 제12권2호
    • /
    • pp.168-173
    • /
    • 2008
  • Purpose: To evaluate the results of treatments by percutaneous Acutrak screw fixation for intra-articular joint depression type fracture of calcaneus. Materials and Methods: Thirteen cases with intra-articular joint depression type fracture of calcaneus, from September 2004 to March 2006, were reviewed. There were 9 males and 4 females with 52.5 years old mean age (range: $31{\sim}74$ years old). The average follow-up period was 18 months (range: $8{\sim}32$ months). Steinmann pins and Freers were used for closed reduction. After closed reduction, Acutrak screws and K-wires were inserted. The patients were evaluated with Creighton-Nebraska health foundation assessment sheet for calcaneal fracture, the extent of recovery of Bohler angle, fragment size, and state of subtalar joint. Results: Clinical results according to Creighton-Nebraska health foundation assessment sheet for calcaneal fracture were excellent in 6 cases (46%), good in 4 cases (30%), fair in 2 cases (15%), and poor in 1 case (7%). Average preoperative Bohler angle was $7.6^{\circ}$ (range: $2^{\circ}{\sim}13^{\circ}$). Average postoperative Bohler angle was $24.4^{\circ}$ (range: $4^{\circ}{\sim}33^{\circ}$). There were no soft tissue complications. There were one mild subtalar arthritis and one moderate subtalar arthritis. Conclusion: We think that closed reduction and percutaneous Acutrak screw fixation with or without K-wire is a good option for joint depression type fracture of calcaneus.

  • PDF

슬링을 이용한 목 안정화 운동 시 아래턱 위치가 고유수용성감각과 관절가동범위에 미치는 영향 (The Effect of Mandible Position on Proprioception and Range of Motion during Neck Stabilization Exercise using a Sling)

  • 채정병;정주현
    • PNF and Movement
    • /
    • 제16권1호
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The aim of this study was to investigate the effect of mandible position on proprioception and range of motion (ROM) during neck stabilization exercise using a sling in healthy adults. Methods: The subjects were randomly assigned to either a sling exercise and mandible open group (n=10) or a sling exercise and mandible closed group (n=12). The sling exercise-mandible open group and sling exercise-mandible closed group took part in an exercise program for 30min, three times per week for 4 weeks. After each training session, head repositioning accuracy (HRA) and the ROM of the cervical spine were measured. Wilcoxon's test was conducted to verify changes within each group, and the Mann-Whitney U test was performed to examine between-group differences. Results: The HRA of the cervical spine was significantly increased during left rotation and extension in the sling exercise-mandible open group. In addition, there were significant differences in both rotations and extension in the two groups. The ROM of the cervical spine increased significantly during both rotations in the sling exercise-mandible closed group. In addition, there was a significant difference in right rotation and extension in both groups. Conclusion: Cervical stabilization exercise using a sling, with the mandible closed increased proprioception and the ROM of the cervical spine.

하악과두골절시 Arthrocentesis와 Lavage를 이용한 치험에 관한 연구 (TREATMENT OUTCOME OF MANDIBULAR CONDYLAR FRACTURE WITH ARTHROCENTESIS AND LAVAGE)

  • 윤옥병
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.286-289
    • /
    • 2002
  • In the treatment of mandibular condylar fractures, arthrocentesis, lavage and selective intermaxillary fixation were performed after closed reduction. In this lavage group, the physiotherapy performed for 3-6 months after injury. in control group, continuous intermaxillary fixation was done for 1-3 weeks, and physiotherapy followed in the same method of the lavage group. In the comparative study of the both groups, the following results are shown. 1. Compared to control group, the lavage group had a slightly superior result at range of motion, joint pain and occlusal deviation, from I day after arthrocentesis to 6 months after injury. 2. The significant differences between both groups were seen at range of motion and joint pain in 1 month after injury. 3. At 6 months after injury, the differences between both groups were not significant at range of motion, joint pain and occlusal deviation. From this study, in the mandibular condylar fracture, the arthrosentesis, lavage and selective intermaxillary fixation after closed reduction can improve symptoms such as joint pain and occlusal deviation, also increase range of motion. in this therapeutic way, intracapsular hemarthrosis which can cause TMJ ankylosis or dysfunction can be removed effectively. in addition, patient's discomfort such as swallowing disturbance, speech disturbance and emotional stress can be reduced signuficantly.

초등학교(初等學校) 시설(施設)의 통폐합(統廢合) 기준(基準) 및 유형(類型)에 관한 연구(硏究) (A Study on Unified-Closed Standards and Types of Elementary School)

  • 김승제;원승현
    • 교육시설
    • /
    • 제8권2호
    • /
    • pp.27-40
    • /
    • 2001
  • The opinion on merits and defects caused the unified-closed of a school facilities have collected by a people and government since the unified-closed system was enforced. There is a problem that the data occurring in the middle of the unified-closed is not analized. Therefore, in this study the target is elementary schools in kyung-gi province which did the unified-closed. First, this study is for analysing which condition influenced to make them. Second, it is for understanding the problems occurred in the process of the unified-closed and presenting the direction of improvement. Third, it is for setting up the planned guide by classification of school facility for the unified-closed which considers the previous problems sufficiently. The range of the study treats of general trend and analysis about the unified-closed of elementary school. The core subject is to analyse the standard and classification of the unified-closed of the object school by the policy of the unified-closed and to compare the carried process of the case school.

  • PDF

변환요소에 따른 LOOPED WIRE의 탄성 변화에 관한 연구 (A STUDY ON THE CHANGES OF THE ELASTIC PROPERTIES TN LOOPED WIRES BY VARIABLE FACTORS)

  • 나용인;김상철
    • 대한치과교정학회지
    • /
    • 제25권3호
    • /
    • pp.263-271
    • /
    • 1995
  • Canine retraction spring과 같은 looped wire에서, 각 변환요소에 따라 변하는 탄성 정도를 알아보기 위하여, wire의 재료, 굵기, loop에 소요된 길이, loop의 모양, gabling의 여부 등 5가지의 변환요소를 설정하여, 각 wire activation시의 탄성을 range, force, stiffness등의 면에서 알아보고자 하였다. wire의 재료적인 면에서 Hi-T (Unitek Co.)와 blue Elgiloy (Rocky Mountain Orthodontics)를 선택하였으며, 굵기로는 .016"$\;\times\;$.022" 와 .018"$\;\times\;$.025"를 선택하였다. loop 자체에 소요된 wire 길이를 15mm와 20mm의 두가지로, loop의 모양을 vertical open loop과 vertical closed loop의 두가지로, gabling의 양을 $0\circ$$30\circ$의 두가지로 하여 각각 제작하였다. 따라서 wire의 재료와 굵기, loop의 길이와 모양, gabling의 5가지 변환요소에 따라 32개군으로 구분되었으며, 각 군의 시료수는 8개씩으로, 총 256개의 시료를 대상으로 하였다. Instron(4202, Instron Co, USA)을 사용하여 각 시료의 하중변형 곡선을 얻었으며 elastic limit에서의 하중과 변형을 계측하고, 그때의 stiffness(force/range)를 산출하여, ANOVA 등의 통계처리로 32개군 간의 상관성을 조사하였다. 그 결과 wire의 재료, 굵기, loop의 길이, 모양, gabling모두가 looped wire의 하중 변형도에 유의한 영향을 미치는 것을 관찰할 수 있었으며, 탄성범위에서의 force는 Hi-T, .016"$\;\times\;$.022", loop 길이 20mm, open loop, non-gable군에서 가장 적었으며, blue Elgiloy, .018"$\;\times\;$.025", loop 길이 15mm, closed loop, non-gable군에서 가장 컸다. 탄성범위에서의 range는 Hi-T, .018"$\;\times\;$.025", loop길이 15mm, open loop, non-gable군이 가장 적었으며, Hi-T, .016"$\;\times\;$.022", loop길이 20mm, closed loop, gable군에서 가장 컸다. 또한 Looped wire의 탄성에 가장 큰 영향을 미치는 변환요소는 loop의 모양과 길이였으며, gabling의 영향이 가장 적었다.

  • PDF

폐회로 디젤엔진의 연소특성에 관한 고찰 (An Investigation on Combustion Characteristics of The Closed Cycle Diesel Engine)

  • 박신배
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.60-69
    • /
    • 2000
  • In order to obtain underwater or underground power sources, the closed cycle diesel engine is operated in the non air-breathing circuit system where the major species of the working fluid include oxygen, argon, and recycled exhaust gas. In the present study, the closed cycle diesel engine is designed to operate at the intake pressure between 2 and 3 bar. For operating in the open-cycle and closed-cycle situations, experimental apparatus using this diesel engine is made with ACAP as data acquisition system. In open, semi-open, and closed cycle modes, the predicted p-$\theta$ and P-V are compared with load bank power. Computation have been performed for wide range of major experimental parameters such as the specific fuel and oxygen concentrations, fuel conversion efficiency and polytropic exponent, IMEP and maximum cylinder pressure.

  • PDF

Cases Report on Conservative Treatment for the Chronic Closed Lock of Temporomandibular Joint

  • Lee, Gi-Cheol;Park, Su-Hyun
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.85-91
    • /
    • 2011
  • Some treatment methods have been proposed for patients with chronic closed lock of temporomandibular joint. We report a conservative treatment for patients who had chronic closed lock of temporomandibular joint and who did not want surgical treatment. Two patients who had been treated in the Template clinic, Soonchunhyang University Bucheon Hospital, are the subjects of this report. The subjects had chronic closed lock symptom for over 3 months after an onset of locking; conventional therapies had no effect. The subjects were treated by making them wear a Template appliance while sleeping and exercise for 10 hours a day. After periodic follow-up, significant improvement was observed for Template treatment in terms of the maximal mouth opening range. When conventional therapy is expected to be ineffective, The Template appliance can be used as conservative treatment for temporomandibular disorders patients with chronic closed lock of temporomandibular joint.