• Title/Summary/Keyword: chromatography test

Search Result 733, Processing Time 0.033 seconds

Preparation of Radiopharmaceuticals (IV) Quality Control and Chemical Analysis of Radiopharmaceuticals (방사성의약품 합성 방식에 관한 연구 제4보 방사성의약품의 품질관리 및 안정도 시험)

  • Kim, You-Sun;Kim, Tae-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.51-60
    • /
    • 1970
  • In 1969 this laboratory had prepared 131 mc. of radiopharmaceuticals in total (Hippuran and other four kinds) and distributed to the major medical establishments. The quality and stability of these products were reviewed by means of radio paper partition chromatography and thin layer chromatography and results were compared to those of foreign products. Generally, the quality and stability of the product of this laboratory were better than those of the foreign product, even though the properties of the radiopharmaceutical were varied by the procedure of the preparation adopted. Various precautions for handling radiopharmaceuticals for clinical use were also described with a view of quality control and stability test there of.

  • PDF

Investigation of Antioxidative Substances in Black Sesame Seed (검은깨의 항산화 활성물질)

  • Ahn, Chan-Young;Hyun, Kyu-Hwan;Park, Keun-Hyung
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.31-36
    • /
    • 1992
  • The antioxidative substances in black sesame and white sesame seed were investigated. The thiocyanate test indicated the presence of antioxidative substances in the extracts of black sesame seed as well as white sesame seed. The activity of white sesame seed was more strong than that of black sesame seed. The active components were discussed after purified using silica gel adsorption chromatography, Sephadex LH-20 chromatography, $C_{18}$ column chromatography, successively.

  • PDF

The Efficient Analysis Test Method of Protein (단백질의 능률적인 분석실험법 (실험지도를 중심으로))

  • 신형준
    • The Korean Journal of Food And Nutrition
    • /
    • v.3 no.2
    • /
    • pp.207-210
    • /
    • 1990
  • Paper chromatography and (NH4)2SO4 precipitation method were used for refinement and separation of proteins Color reaction was tested by Biuret test, Million test, Xanthoprotein test, and Ninhydrin test. Precipitation reaction and coagulation of proteins were tested by heating method (Ethanol, HNO3).

  • PDF

A Preparative Purification Process for Recombinant Hepatitis B Core Antigen Using Online Capture by Expanded Bed Adsorption Followed by Size-Exclusion Chromatography

  • Ho, Chin Woi;Tan, Wen Siang;Chong, Fui Chin;Ling, Tau Chuan;Tey, Beng Ti
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Hepatitis B core antigen(HBcAg) is an important serological marker used in the diagnosis of hepatitis B virus(HBV) infections. In the current study, a fast and efficient preparative purification protocol for truncated HBcAg from Escherichia coli disruptate was developed. The recombinant HBcAg was first captured by anion exchange expanded bed adsorption chromatography integrated with a cell disruption process. This online capture process has shortened the process time and eliminated the "hold-up" period that may be detrimental to the quality of target protein. The eluted product from the expanded bed adsorption chromatography was subsequently purified using size-exclusion chromatography. The results showed that this novel purification protocol achieved a recovery yield of 45.1% with a product purity of 88.2%, which corresponds to a purification factor of 4.5. The recovered HBcAg is still biologically active as shown by ELISA test.

Optimization of disposable paper-based test strips for hypochlorous acid detection

  • Rita E. Ampiaw;Muhammad Yaqub;Changyeon Woo;Wontae Lee
    • Membrane and Water Treatment
    • /
    • v.14 no.4
    • /
    • pp.181-189
    • /
    • 2023
  • The Covid-19 pandemic has increased demand for chlorine-based sanitizing solutions, most of which contain hypochlorous acid (HOCl) as an active agent. Free chlorine (HOCl) in these sanitizers is crucial for their efficacy. Disposable test strips are affordable and convenient tools for determining various qualitative and quantitative parameters. In this study, disposable opto-chemical test strips were developed by physically immobilizing 3,3',5,5'-tetramethylbenzidine (TMB) and o-dianisidine (o-D) reagents on chromatography and filter paper-based test strips for the visualization and detection of free chlorine in the form of HOCl. The reagents undergo a rapid color change upon reaction with chlorine through a redox reaction. The paper-based test strips showed rapid color change within a minute and a low sample volume requirement (1 ml). This portable, disposable paper-based test strip is a simple and cost-effective way to rapidly detect the presence of HOCl sanitizers for home and field applications. Both TMB and o-D successfully detected chlorine. Chromatography paper proved to be the more efficient option among the two papers used as substrates for the reagents (TMB and o-D). It exhibited high retention capacity and high performance in terms of color transformation when reacting with HOCl, even after two months of storage.

A Survey of Total Aflatoxins in Food Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Liquid Chromatography Tandem Mass Spectrometry(LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 식품 중 총아플라톡신 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Cho, Sung-Hye;Park, Joon-Shik;Kwon, Eun-Young;Lee, Eun-Jin;Kim, So-Hee;Kim, Dai-Byung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.488-493
    • /
    • 2007
  • A survey for total aflatoxins (aflatoxins $B_1$, $B_2$, $G_1$, and $G_2$) was conducted on 245 cereals and processed cereal products, and 148 nuts and processed nut products in Korea, for a total of 393 commercialized ed samples. The total aflatoxins were quantified by the immunoaffinity column clean-up method with high performance liquid chromatography (HPLC) - fluorescence detection (FLD), and were confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Total aflatoxins(AFs) were detected in 37 samples (9.4% incidence), including 2 millet samples, 1 mixed cereal (sunsik), 1 powdered malt sample, 2 processed cereal products, 6 peanut samples, 22 peanut butter samples, and 1 sample each of almonds, adlay tea, and a processed nut product. The contamination levels were $0.04-2.65{\mu}g/kg$ for aflatoxin $B_1$, and $0.04-5.51{\mu}g/kg$ for total aflatoxins. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected aflatoxins, and all 37 samples showing aflatoxins by HPLC-FLD were confirmed by LC-MS/MS.

A Survey of Zearalenone in Beans Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Ultra Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 두류 중 제랄레논 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hui;Lee, Hyo-Jeong;Kim, Ji-Yeon;Son, Sang-Hyeok;Sin, Chun-Sik;Kim, So-Hui;Kim, Dae-Byeong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.354-359
    • /
    • 2008
  • A survey for zearalenone contamination was conducted on 27 soy bean samples, 27 red bean samples, 16 black bean samples, 19 seoritae samples, 14 seomoktae samples, for a total of 127 commercial Korean samples. Zearalenone was quantified by the immunoaffinity column clean-up method with high performance liquid chromatography-fluorescence detection (HPLC-FLD), and was confirmed by liquid chromatography tandem mass spectrometry(LC-MS/MS). The limits of detection and quantification were $2.0{\mu}g/kg$ and $6.0{\mu}g/kg$, respectively. The recovery in the beans ranged from 82.2 to 98.4%. According to HPLC-FLD, zearalenone was detected in 13 samples (10.2% incidence), including 1 soybean and 12 red bean samples. The zearalenone contamination levels were in the range of 8.01${\sim}38.98{\mu}g/kg$. Finally, LC-MS/MS analysis was conducted in the contaminated samples to verify the results of HPLC-FLD. The LC-MS/MS results confirmed the presence of zearalenone in all 13 samples. The contamination level was lower than that of EU, which is below $100{\mu}g/kg$ for raw grains.

Characteristic Impact Odorants of Changpo (Acorus calamus var. angustatus Bess) Root Essential Oil

  • Choi, Hyang-Sook
    • Food Science and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.450-455
    • /
    • 2005
  • This study was conducted to determine firstly the composition of the essential oil from fresh changpo (Acorus calamus var. angustatus Bess) roots quantitatively and qualitatively by use of two internal standards, and secondly volatile compounds which are primarily responsible for the aroma of changpo roots. Simultaneous steam distillation and extraction method was used for essential oil extraction, and aroma extract dilution analysis (AEDA) and sniffing test by gas chromatography/olfactometry (GC/O) were used to detect the characteristic impact odorants. According to the instrumental analysis of changpo root essential oil, cis, trans-famesol (47.56 mg/kg of fresh wt), octanoic acid (23.73 mg/kg of fresh wt), trans-2-dodecenal (20.28 mg/kg of fresh wt) and trans, trans-farnesol (13.81 mg/kg of fresh wt) were the most abundant compounds. Geranyl acetate, trans-nerolidol and trans, trans-farnesyl acetate were evaluated as the characteristic impact odorants of changpo roots from results of AEDA and sniffing test. Especially, geranyl acetate was considered as the most similar odor component to changpo roots by organoleptic evaluation with GC/O.

Analysis of Zearalenone Contamination in Cereal-Based Products Using High Performance Liquid Chromatography-Fluorescence Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (곡류가공품 중 제랄레논 오염도 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Choi, In-Sun;Shin, Choon-Shik;Kim, Jin-Hee;Jang, Young-Mi;Kim, Dong-Sul;Ahn, Dong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.224-229
    • /
    • 2011
  • Zearalenone (ZEA) is an estrogenic mycotoxin mainly produced by Fusarium graminerum, a species which colonizes a wide variety of cereals, including wheat, barley and processed products. A survey of ZEA contamination was conducted on 141 dried confectioneries, 59 breads and rice cakes, 135 noodles and 101 other products, for a total of 432 commercial samples. Samples were analyzed by high performance liquid chromatography with fluorescence detection (HPLC-FLD) after immunoaffinity clean-up and was confirmed by liquid chromatography tandem mass spectrometry (LCMS/MS). The limits of detection and quantification were 2.0 and $6.0{\mu}g/kg$, respectively. The recovery ranged from 80.2% to 98.4% in the cereal based product. ZEA was detected in 38 samples (8.8% incidence), including 3 snack, 2 biscuit and 33 other cereal products. The ZEA contamination levels were in the range of $5.38-53.76{\mu}g/kg$. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected ZEA, and all 38 samples showing ZEA by HPLC-FLD were confirmed by LC-MS/MS.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF