• 제목/요약/키워드: chemical states

검색결과 851건 처리시간 0.032초

BCl3/Ar 유도결합 플라즈마 안에 CH4 가스 첨가에 따른 건식 식각된 TaN 박막 표면의 연구 (A Study on the Surface of the Dry Etched TaN Thin Film by Adding The CH4 Gas in BCl3/Ar Inductively Coupled Plasma)

  • 우종창;최창억;양우석;주영희;강필승;전윤수;김창일
    • 한국전기전자재료학회논문지
    • /
    • 제26권5호
    • /
    • pp.335-340
    • /
    • 2013
  • In this study, the plasma etching of the TaN thin film with $CH_4/BCl_3/Ar$ gas chemistries was investigated. The etch rate of the TaN thin film and the etch selectivity of TaN to $SiO_2$ was studied as a function of the process parameters, including the amount of $CH_4$. X-ray photoelectron spectroscopy (XPS) and Field-emission scanning electron microscopy (FE-SEM) was used to investigate the chemical states of the surface of the TaN thin film.

부식억제제로 모노에탄올아민을 사용한 금속의 전기화학적 특성 (Electrochemistry Characterization of Metal Using Monoethanolamine as Corrosion Inhibitor)

  • 박근호
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.88-94
    • /
    • 2012
  • 순환전압전류법을 사용하여 전류-전압 곡선을 측정하였다. 전기화학적 특성과 금속의 표면상태간의 관계는 전자현미경(SEM)을 사용하여 조사하였다. 그리고 순환전압전류법에 의한 전기화학적 측정은 3 전극 시스템을 사용하였다. 측정 범위는 초기 포텐셜에서 -1350 mV까지 환원시키고, 연속적으로 1650 mV까지 산화시키고, 다시 초기지점으로 환원시켜 측정하였다. 스캔속도는 50, 100, 150, 200 및 250 mV/s를 선정하였다. 그 결과, 부식억제로 모노에탄올아민(MEA)을 사용하여 금속의 C-V 특성은 순환전압전류법으로부터 산화 전류에 기인한 비가역 공정으로 나타났다. 부식억제제로 MEA을 사용하였을 경우에는 전해질의 농도가 증가할수록 확산계수가 감소하는 경향을 나타내었다. 그리고 구리의 SEM 이미지를 보면, 전해질 농도를 증가시키면 표면부식은 증가하였다. 부식억제제로 $1.0{\times}10^{-3}M$ MEA를 첨가시키면, 전해질 농도 0.1 N의 경우 확산계수가 상대적으로 커서 부식억제 효과가 적었다.

Structural Evolution of Layered $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ upon Electrochemical Cycling in a Li Rechargeable Battery

  • 홍지현;서동화;김성욱;권혁조;박영욱;강기석
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.37.2-37.2
    • /
    • 2010
  • Recently $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ has been consistently examined and investigated by scientists because of its high lithium storage capacity, which exceeds beyond the conventional theoretical capacity based on conventional chemical concepts. Consequently, $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ is considered as one of the most promising cathode candidates for next generation in Li rechargeable batteries. Yet the mechanism and the origin of the overcapacity have not been clarified. Previously, many authors have demonstrated simultaneous oxygen evolution during the first delithiation. However, it may only explain the high capacity of the first charge process, and not of the subsequent cycles. In this work, we report a clarified interpretation of the structural evolution of $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$, which is the key element in understanding its anomalously high capacity. We identify how the structural evolution of $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ occurs upon the electrochemical cycling through careful study of electrochemical profiles, ex-situ X-ray diffraction (XRD), HR-TEM, Raman spectroscopy, and first principles calculation. Moreover, we successfully separated the structural change at subsequent cycles (mainly cation rearrangement) from the first charge process (mainly oxygen evolution with Li extraction) by intentionally synthesizing sample with large particle size. Consequently, the intermediate states of structural evolution could be well resolved. All observations made through various tools lead to the result that spinel-like cation arrangement and lithium environment are created and embedded in layered framework during repeated electrochemical cycling.

  • PDF

SIMS를 이용한 SiO2/PSG/SiO2/Al-1%Si 및 SiO2/TEOS/SiO2/Al-1%Si 적층 박막내의 Na 게터링 분석 (Analysis of the Na Gettering in SiO2/PSG/SiO2/Al-1%Si and SiO2/TEOS/SiO2/Al-1%Si Multilevel Thin Films using SIMS)

  • 김진영
    • 한국표면공학회지
    • /
    • 제51권2호
    • /
    • pp.110-115
    • /
    • 2018
  • The Na low temperature gettering in $SiO_2/PSG/SiO_2/Al-1%Si$ and $SiO_2/TEOS/SiO_2/Al-1%Si$ multilevel thin films was investigated using dynamic SIMS(secondary ion mass spectrometry) analysis. DC magnetron sputter, APCVD and PECVD techniques were utilized for the deposition of Al-1%Si thin films, $SiO_2/PSG/SiO_2$ and $SiO_2/TEOS/SiO_2$ passivations, respectively. Heat treatment was carried out at $300^{\circ}C$ for 5 h in air. SIMS depth profiling was used to determine the distribution of Na, Al, Si and other elements throughout the $SiO_2/PSG/SiO_2/Al-1%Si$ and $SiO_2/TEOS/SiO_2/Al-1%Si$ multilevel thin films. XPS was used to analyze chemical states of Si and O elements in $SiO_2$ passivation layers. Na peaks were observed throughout the $PSG/SiO_2$ and $TEOS/SiO_2$ passivation layers on the Al-1%Si thin films and especially at the interfaces. Na low temperature gettering in $SiO_2/PSG/SiO_2/Al-1%Si$ and $SiO_2/TEOS/SiO_2/Al-1%Si$ multilevel thin films is considered to be caused by a segregation type of gettering.

Bone-like Apatite Formation on Ultrafine-Structure in Modified Electrolytic Solution

  • Jang, Jae-Myung;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.155-155
    • /
    • 2017
  • Surface modifications are commonly utilized to adjust the properties of the titanium and its alloy surface to the specific needs of the medical applications, but there are disadvantages such as poor osteoconductive properties and low adhesion of bone cell to implant surface. In order to improve these disadvantages, changes in surface properties have an important effect on osseointegration during implantation. In this paper we applied new technological method for improving a unique surface modification using the characteristic of an electrolytic Solution. Thus, in the electrolyte containing NaF in Na2SO4, TiO2 nanoporous was uniformly formed, and HAp nanoparticles were electrodeposited around the TiO2 nanopores, but in the electrolyte containing NH4F in (NH4)H2PO4, the coarse protrusions including HAp nano particles were regularly deposited onto the TiO2 barrier layer. The surface characteristics and the distributed elements and have been investigated by EDS analysis, and ultra-fine structure of surface are carried out using FE-SEM. To investigate the behavior of the anion, the analysis of chemical states was performed by XPS, and the narrow spectrums for Ti2P, Ca 2p, and P 2p seems to be almost similar depending on the characteristics of the electrolyte solution respectively. In addition, Ca 2p spectrum could be resolved into two peaks for Ca 2p3/2 and 2p1/2 at 347.4 and 351.3 eV, which are related to hydroxyapatite. And, the P peak can also be deconvoluted into two peaks for P1/2 and P3/2 levels with binding energy 134.2 and 133.4 eV, respectively. From the result of soaking test, the apatite morphologys were well-formed onto the modified surface according to the different conditions.

  • PDF

내연기관의 엔진오일상태에 대한 유전율 변화 특성 (Characteristics of Variant Dielectric Constants With Respect to Internal Combustion Engine Oil States)

  • 김동민;김영주;이승희
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권1호
    • /
    • pp.19-21
    • /
    • 2012
  • 내연 기관의 엔진오일은 열화작용에 의해서 수명이 짧아지고 대기오염을 유발하게 된다. 엔진오일의 상태를 정확히 측정하여 새오일로 교환함으로 엔진의 수명 연장 및 환경오염을 줄일 수 있다. 정전용량 프로브는 엔진오일과 같은 유체의 유전율을 측정하는데 사용 할 수 있다. 본 논문은 엔진 오일의 열화 정도에 따라서 달라지는 유전율 특성을 분석하였다. 오일의 상태에 따라서 달라지는 프로브의 정전용량을 각각 LCR Meter로 측정하여 엔진오일의 유전율을 계산하였다. 또한, 프로브의 크기에 따른 정전용량의 변화를 측정하여 유전율 측정의 정확도를 제시한다. 오염된 오일 일수록 유전율이 증가하며, 유전율로 오일의 오염정도를 판단하는 것이 가능하다.

Current Management Status of Mercury Emissions from Coal Combustion Facilities: International Regulations, Sampling Methods, and Control Technologies

  • Lee, Sung-Jun;Pudasainee, Deepak;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권E1호
    • /
    • pp.1-11
    • /
    • 2008
  • Mercury (Hg), which is mainly emitted from coal-fired power plants, remains one of the most toxic compounds to both humans and ecosystems. Hg pollution is not a local or regional issue, but a global issue. Hg compounds emitted from anthropogenic sources such as coal-fired power plants, incinerators, and boilers, can be transported over long distances. Since the last decade, many European countries, Canada, and especially the United States, have focused on technology to control Hg emissions. Korea has also recently showed an interest in managing Hg pollution from various combustion sources. Previous studies indicate that coal-fired power plants are one of the major sources of Hg in Korea. However, lack of Hg emission data and feasible emission controls have been major obstacles in Hg study. In order to achieve effective Hg control, understanding the characteristics of current Hg sampling methods and control technologies is essential. There is no one proven technology that fits all Hg emission sources, because Hg emission and control efficiency depend on fuel type, configuration of air pollution control devices, flue gas composition, among others. Therefore, a broad knowledge of Hg sampling and control technologies is necessary to select the most suitable method for each Hg-emitting source. In this paper, various Hg sampling methods, including wet chemistry, dry sorbents trap, field, and laboratory demonstrated control technologies, and international regulations, are introduced, with a focus on coal-fired power plants.

Seasonal Distribution of Ticks in Four Habitats near the Demilitarized Zone, Gyeonggi-do (Province), Republic of Korea

  • Chong, Sung Tae;Kim, Heung Chul;Lee, In-Yong;Kollars, Thomas M. Jr.;Sancho, Alfredo R.;Sames, William J.;Chae, Joon-Seok;Klein, Terry A.
    • Parasites, Hosts and Diseases
    • /
    • 제51권3호
    • /
    • pp.319-325
    • /
    • 2013
  • This study describes the seasonal distribution of larvae, nymph, and adult life stages for 3 species of ixodid ticks collected by tick drag and sweep methods from various habitats in the Republic of Korea (ROK). Grasses less than 0.5 m in height, including herbaceous and crawling vegetation, and deciduous, conifer, and mixed forests with abundant leaf/needle litter were surveyed at United States (US) and ROK operated military training sites and privately owned lands near the demilitarized zone from April-October, 2004 and 2005. Haemaphysalis longicornis Neumann adults and nymphs were more frequently collected from April-August, while those of Haemaphysalis flava Neumann and Ixodes nipponensis Kitaoka and Saito were collected more frequently from April-July and again during October. H. longicornis was the most frequently collected tick in grass habitats (98.9%), while H. flava was more frequently collected in deciduous (60.2%) and conifer (57.4%) forest habitats. While more H. flava (54.1%) were collected in mixed forest habitats than H. longicornis (35.2%), the differences were not significant. I. nipponensis was more frequently collected from conifer (mean 8.8) compared to deciduous (3.2) and mixed (2.4) forests.

Reproducible Resistance Switching and Physical Characteristics of TiOx films with Oxidation Temperature and Time

  • Kim, Jong-Gi;Na, Hee-Do;Sohn, Hyun-Chul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.171-171
    • /
    • 2010
  • In this work, we investigated the effect of the oxidation temperature on the unipolar and bipolar resistance switching behaviors of the oxidized TiO-x films. TiOx films on Pt electrodes were fabricated by the oxidation of Ti films at $550^{\circ}C$ for 1 to 3 hours. The unipolar and bipolar resistance switching properties were investigated with the oxidation temperature and time. Also, the crystal structure and the physical properties such as chemical bonding states of TiOx layers were characterized in addition to the resistance switching characteristics. The resistance switching behaviors of TiOx films oxidized at above $450^{\circ}C$ and below $650^{\circ}C$ was shown. So, we investigated that the resistance switching behaviors of TiOx films oxidized at $550^{\circ}C$ with the oxidation time from 1 to 3 hour. The memory windows of unipolar switching in the oxidized TiOx films were reduced with increasing the oxidation time, but those of the bipolar switching were slightly enlarged. The enlargement of rutile TiO2 peak with increasing the oxidation time and temperature was studied by X-ray diffraction. An increase of non-lattice oxygen and Ti3+ in the TiOx films with the oxidation times was investigated by X-ray photoemission spectroscopy. It was expected that the uipolar and bipolar resistive switching of the oxidized TiOx film was strongly related with the migration of non-lattice oxygen anions and schottky barrier height, respectively.

  • PDF

한국의 저서성 대형무척추동물 생태점수 개선 (Revision of Ecological Score of Benthic Macroinvertebrates Community in Korea)

  • 공동수;박영준;전용락
    • 한국물환경학회지
    • /
    • 제34권3호
    • /
    • pp.251-269
    • /
    • 2018
  • In 1997, the environmental score (Q) corresponding the tolerance value of Korean benthic macroinvertebrate species and the related biotic score, the ecological score of benthic macroinvertebrates (ESB) were proposed; ESB was similar to Beck's biotic index or Chandler's biotic score. This study was carried out to revise the Q values of individual species and the assessment scheme of ESB based on the taxonomic performance and ecological information accumulated since then. The original ESB was renamed as TESB (total ESB), and AESB (average ESB) was newly proposed. AESB is calculated by dividing the TESB (for a given station) by the number of species present in the sample. In this study, TESB showed a positively skewed distribution, while AESB showed a negatively skewed distribution. The correlation between TESB and the concentration of $BOD_5$ was a little stronger than that of the original ESB. TESB showed a very strong correlation (correlation coefficient r = 0.98) with Margalef's species richness, of which correlation coefficient was higher than that of AESB (r = 0.85). AESB showed a strong correlation (r = -0.79) with the concentration of $BOD_5$, while TESB showed a weaker correlation (r = -0.67). Applying TESB and AESB together in an assessment of the environment may be comprehensive because the physical and chemical states of the environment can be evaluated together. AESB is less dependent on the sample size, while TESB tends to increase as the sample size increases. In the evaluation of the environment using TESB, it is necessary to standardize the methods on monitoring.