• Title/Summary/Keyword: chambers

Search Result 895, Processing Time 0.036 seconds

Effect of long-term high-fat diet and fasting on energy metabolic substrates utilization in resting rats

  • Jeon, Yerim;Kim, Jisu;Hwang, Hyejung;Suh, Heajung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.15 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The effects of a high-fat diet and fasting on resting energy expenditure and energy substrate utilization were examined using the method of measuring whole body energy metabolism and oxygen uptake. Eight 4-week old male Sprague-Dawley rats were used for the high-fat diet experiment. Energy metabolism was measured using acrylic metabolic chambers over 24 hours. After 1-week of preliminary feeding, 4 rats were fed a chow diet, whereas the remaining 4 rats were fed a high-fat diet (HF) ad libitum, which contained 40% (w/w, calorie base 60%) more fat than that in the chow diet. The flow rate to measure energy metabolism inside the chamber was controlled at a mean of 3.5 L/min, and five chambers were subjected to measurement. One of the five chambers was used to correct errors by measuring the atmosphere. As a result of 5 weeks of control diet and high-fat diet feeding, body weight of the high-fat diet group tended to increase more than that in the control diet fed group, but the difference was not significant. Oxygen uptake and carbon dioxide production changed as time went on over the 24 hr. The respiratory exchange ratio also changed during the 24 hr, and the difference between the groups was significant. The control group showed significantly more carbohydrate oxidation than that of the high-fat diet fed group. A fasting experiment was conducted using six 7-week old Sprague-Dawley male rats. Energy metabolism measurements were performed using the same method as that used in the high-fat diet experiment; resting metabolism was measured prior to fasting, and a fasting condition began from 9:00 am the next day for 3 days to calculate energy metabolism. Both body weight and 24-hour oxygen uptake decreased significantly as a result of 3-day fasting. Total oxygen uptake in the first day decreased, and declined significantly on day 3 of fasting. Total 24-hour carbon dioxide production decreased significantly over the 3 days. The mean 24-hour respiratory exchange ratio decreased significantly. Additionally, energy expenditure during the dark period (20:00-08:00), which is the active period for rats, decreased significantly with fasting, whereas energy expenditure during the light period (08:00-20:00) did not increase by fasting.

An Optimal Standardized in vitro Bioassay to Evaluate Susceptibility of Green Peach Aphid, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), to Aphicides (복숭아혹진딧물, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), 살진딧물 최적 in vitro 살충력 검정 방법 확립)

  • Ka Hee Cho;Hyo Jung Kim;Young Cheol Kim
    • Korean journal of applied entomology
    • /
    • v.62 no.3
    • /
    • pp.139-147
    • /
    • 2023
  • Leaf-spray in vitro bioassays appraise new aphicidal formulations for managing deleterious plant-feeding aphids. The formulation may utilize alternative and integrated strategies. However, leaf spraying even under controlled conditions may affect aphid reproduction and mortality. This study examines leaf spray applications for optimum and reproducible aphicidal results using tobacco leaves overlaid on cotton fabric or water agar surfaces. Infestation of the undersides of tobacco leaves with nymphs of green peach aphids was used in the assays. Spray distance and volume were optimized using water-sensitive paper to ascertain the best surface coverage. Overlays of the leaves on water agar caused less mortality and greater reproduction than the use of cotton fabric. The relative humidity of the insect-rearing chambers changed with the watering regime for the insect - rearing chambers with cotton fabric; 60% relative humidity was optimal. Relative humidity was not affected by the concentration of agar in the water agar chambers. Applications of the chemical aphicidal standard, Sulfoxaflor, under the optimized conditions exhibited similar times for lethality although the rate was faster with leaves on the cotton fabric than on water agar. These studies establish reproducible and sensitive techniques for assessing the lethality and effects on reproduction of potential aphicidal products.

Design and Fabrication of Wide-band Ferrite Absorber Used in Anechoic Chamber

  • Kim, Sung-Soo;Park, Ik-Kown
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1997
  • Ferrite tile absorber is of great concern for the application to anechoic chambers due to the growing demand of EMI or EMC measurements. This paper investigates the magnetic, dielectric and microwave absorbing properties of a Ni-An ferrite for the purpose. A design chart was constructed with the solutions of impedance-matching equation in the radio frequencies (30 MHz - 1 GHz). The material parameters for zero-reflection are predicted from the chart. The magnetic and dielectric properties of sintered Ni-Zn ferrite is found to be well suited for this requirements. A superior microwave absorbing properties (frequency band and absorber thickness) of the samples are demonstrated.

  • PDF

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

UHV Welding for The PLS Vacuum Chambers (포항가속기 저장링 진공 Chamber 용접)

  • 최만호;정상수;김효윤;김명진;이해철;한영진;최우천
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.275-281
    • /
    • 1993
  • 본 논문은 포항가속기에서 건설 중인 진공 chamger의 용접에 관한 것이다. 저장링에 전자빔을 5시간 이상 저장하기 위하여 10-10torr 이하로 진공도를 유지하도록 설계되어 있기 때문에 초고진공에 적합한 TIG 용접(tungsten inert gas welding)을 하였다. 진공 chamber는 Al 5083-H321이며 flange의 재질은 Al 2219-T852이다. Sector chamber I, II의 총 용접 길이는 각각 27m, 37m이며 진공에 유해한 균열과 virtual leak가 생기지 않도록 하는 용접조건 등을 선정하였다.

  • PDF

PC-based Controller for Industrial Solid Freeform Fabrication System (산업용 SFFS (Solid Freeform Fabrication System)을 위한 PC 기반 제어기)

  • 박남수;황면중;이두용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.73-77
    • /
    • 2004
  • This paper presents a PC-based controller of industrial SFFS(Solid Freeform Fabrication System). The SFFS has multiple sub-controllers for the building room, the powder room, the temperature, and the density of oxygen in the chambers. Hence the main PC-based controller should effectively and timely send commands to the sub-controllers, and monitor the overall SLS process. The required actuators and sensors are selected to optimize the overall performance of the SFFS.

  • PDF

Acoustic Characteristics of Mufflers with an Extended Iinlet and Outlet (입출구가 연장된 동심형 소음기의 음향해석)

  • 이준신;김연환;김태룡;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.536-541
    • /
    • 1998
  • Cylindrical chamber silencers with an extended inlet and outlet are widely used to reduce the propagated noise in ducts in many application fields. In this study, an acoustic analysis is carried out for concentric extended pipes inserted into a simple expansion chambers An algebraic equation is derived by using the eigenfunction expansion and orthogonality principle. Using this analytical method, transmission losses are predicted for several configurations of the concentric extended systems.

  • PDF

TAPVC (성인 전폐정맥 연결이상 [TAPVR] 교정 1례 보고)

  • 유회성
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.123-128
    • /
    • 1978
  • This 18 year old girl with total anomalous venous connection, which was corrected surgically for the first time in Korea, is presented here. This patient has mild cyanosis, ejection systolic murmur with splitting of $S_2$ ,identical $O_2$ saturation of bleed samples from right and left chambers of the heart. The type was supracardiac TAPVC. On conventional cardiopulmonary by pass was used, and an right sided approach was employed. Post-op. course was smooth except for transient arrhythmia, low blood pressure and jaundice. She left hospital in a good general conditions.

  • PDF