• Title/Summary/Keyword: chamber sensitivity

Search Result 153, Processing Time 0.024 seconds

Humidity Sensor Using Microwave Sensor Based on Microstrip Defected Ground Structure Coated with Polyvinyl Alcohol (폴리비닐알코올로 코팅된 마이크로스트립 결함 접지 구조 기반 마이크로파 센서를 이용한 습도 센서)

  • Yeo, Junho;Kwon, Younghwan
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.627-632
    • /
    • 2020
  • In this paper, we have studied a development of a humidity sensor using a microwave sensor based on a microstrip defected ground structure coated with polyvinyl alcohol. A high-sensitivity microwave sensor, which is sensitive to the changes in the permittivity of the material under test, is designed by adding an interdigital capacitor-shaped defected ground structure to the ground plane of a microstrip line. Polyvinyl alcohol, a polymer material whose permittivity varies depending on humidity, is coated with a thin thickness on the defected ground structure of the proposed microwave sensor, and the changes in the resonance frequency and magnitude of the transmission coefficient for the microwave sensor according to humidity are measured. When relative humidity increases from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature/humidity chamber, the resonant frequency of the transmission coefficient decreases from 1.475 GHz to 1.449 GHz, and the magnitude is increased from -32.90 dB to -25.67 dB.

Humidity Sensor Using Microstrip Patch Antenna (마이크로스트립 패치 안테나를 이용한 습도 센서)

  • Junho Yeo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.71-76
    • /
    • 2023
  • In this paper, a humidity sensor using a microstrip patch antenna(MPA) and polyvinyl alcohol(PVA) is studied. PVA is a polymer material whose permittivity changes with humidity, and a rectangular slot is added to the radiating edge of the MPA, which is sensitive to changes in electric field, in order to increase the sensitivity to changes in relative permittivity. After thinly coating the area around the radiating edge with the rectangular slot of the MPA fabricated on a 0.76 mm-thick RF-35 substrate with PVA, the changes in the resonant frequency and magnitude of the MPA's input reflection coefficient are measured when relative humidity is adjusted from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature and humidity chamber. Experiment results show that when the relative humidity increases from 40% to 80%, the resonance frequency of the antenna' input reflection coefficient decreases from 2.447 GHz to 2.418 GHz, whereas the magnitude increases from -7.112 dB to -3.428 dB.

Study on the Thermal Conductivity of Frozen Soil Considering Various Experimental Conditions (다양한 실험조건을 고려한 동결 사질토의 열전도도 산정에 대한 연구)

  • Kim, Hee-Won;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.9
    • /
    • pp.5-11
    • /
    • 2023
  • In analyzing geotechnical structures, the analysis fields are becoming increasingly diversified. In particular, the need for predicting the thermal behavior of ground materials has become important in fields related to soil freezing. To ensure a reliable assessment of the freezing behavior of the ground, considering the variation in the effective thermal conductivity of soil specimens under various conditions is crucial. In this study, probe experiments were conducted by varying the porosity, initial degree of saturation, and read time settings of the meter. Next, the factors influencing the effective thermal conductivity of the frozen sandy soil were evaluated. The experimental results conducted under different porosity conditions showed a tendency for the effective thermal conductivity of frozen soil to increase as the specimen's porosity decreased. However, as the degree of saturation of the specimen increased, the effective thermal conductivity also increased. The sensitivity of the meter's read time setting to the measurement of effective thermal conductivity was observed. When the read time was set to 1 min, the measured values were in a range similar to that obtained in previous studies conducted in Korea with the same soil specimen.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

ANTIMICROBIAL EFFECT OF ANTIBIOTICS AND ROOT CANAL CEMENTS ON THE PREDOMINANT PATHOGENIC ANAEROBIC MICROFLORA IN ROOT CANALS (근관내 주요 혐기성 병인균에 대한 수종 항생제와 근관충전용 세멘트의 항균효과에 관한 연구)

  • Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.515-525
    • /
    • 1993
  • The purpose of this study was to evaluate the susceptibility of anaerobic microorganisms to certain antibiotics and root canal cements. Prevotella intermedia(Bacteroides intermedius) ATCC 25611(serotype A), Fusobacterium nucleatum ATCC 25586, Actinomyces viscosus ATCC 15987 which are the predominant pathogenic anaerobes in dental root canals were cultured in BHI for 48 hours(Fig.1). After each $200{\mu}l$ of those broths with microorganisms was streaked on each surface of blood agar plate, 2 to 5 antibiotic discs which are impregnated with Tetrncycline, Erythromycin, Ampicillin, Clindamycin, or Vancomycin were applied on each surface of blood agar plate and cultured for 5 days anaerobically in the anaerobic chamber (Fig.2). 15 antibiotic discs for each kind of antibiotics and each species of microorganisms were tested. Also each kind of root canal cement tubes which include Zinc oxide eugenol cement, Zinc phosphate cement, Calcium hydroxide powder+DD.W., Calcium hydroxide paste(Pulpdent Tempcanal), or Vitapex(Table 1) were applied on the inoculated BAPs after $200{\mu}l$ of each experimental species of microorganisms was streaked on the surface of blood agar plates, and they were cultured for 5 days anaerobically in the anaerobic chamber(Fig.3). The sensitivity(antimicrobial effect) was determined by the diameter of the inhibition zone. The results are as follows: 1. The results of antibiotic susceptibility test(Table 2) 1) All of the tested antibiotics had antimicrobial activity with various degrees. 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Erythromycin($37.87mm{\pm}2.20$) was largest, those to Tetracycline($26.20mm{\pm}2.96$), Vancomycin($21.53mm{\pm}1.96$), Clindamycin($18.73mm{\pm}0.96$) was smaller than former orderly, and That to Ampicillin ($7.87mm{\pm}0.83$) was smallest. 3) In Actinomyces viscosus, the diameter of inhibition zone to Erythromycin($28.73mm{\pm}1.22$) was largest, those to Ampicillin($21.73mm{\pm}1.03$), Clindamycin($21.33mm{\pm}1.59$) was similarly next order, that to Vancomycin($19.00mm{\pm}1.96$) was smaller than Clindamycin, and that to Tetracycline($11.93mm{\pm}0.70$) was smallest. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Ampicillin($31.07mm{\pm}1.91$) was largest, that to Erythromycin($28.87mm{\pm}0.92$), Clindamycin($20.47mm{\pm}1.51$), Vancomycin ($16.73mm{\pm}0.96$), Tetracycline ($12.13mm{\pm}1.06$) are smaller than former orderly. 2. The results of root canal cements and pastes(Table 3) 1) The external diameter of tube is 4mm, so 4mm of the inhibition zone diameter means non-susceptable. Prevotella intermedia (old Bacteroides intermedius) was non-susceptable to Calcium hydroxide powder+D.D.W., Calcium hydroxide paste(pulpdent Tempcanal), and Actinomyces viscosus was non-susceptable to Zinc phosphate cement, Calcium hydroxide powder + D.D.W., Calcium hydroxide paste(pulpdent Tempcanal). 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Zinc oxide eugenol cement($13.67mm{\pm}3.30$) was largest, that to Vitapex($9.20mm{\pm}2.96$), Zinc phosphate cement($6.13mm{\pm}2.07$) was smaller than former. 3) In Actinomyces viscosus, the diameter of inhibition zone to Zinc oxide eugenol cement($17.40mm{\pm}5.20$) was largest and that to Vitapex($8.80mm{\pm}1.70$) was next order. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Vitapex($42.33mm{\pm}17.2$) was largest and those to Calcium hydroxide paste(Pulpdent Tempcanal)($14.47mm{\pm}3.72$) and Zinc oxide eugenol cement($8.93mm{\pm}2.71$), Zinc phosphate cement($8.20mm{\pm}2.27$), Calcium hydroxide powder+D.D.W.($5.53mm{\pm}2.10$)was next orderly. And then In Zinc oxide eugenol cement and Zinc phosphate cement group, two of fifteen samples showed no inhibition zone, in Calcium hydroxide powder + D.D.W. group, 8 of 15 samples showed no inhibition zone.

  • PDF

The Continuous Measurement of CO2 Efflux from the Forest Soil Surface by Multi-Channel Automated Chamber Systems (다중채널 자동챔버시스템에 의한 삼림토양의 이산화탄소 유출량의 연속측정)

  • Joo, Seung Jin;Yim, Myeong Hui;Ju, Jae-Won;Won, Ho-yeon;Jin, Seon Deok
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.1
    • /
    • pp.32-43
    • /
    • 2021
  • Multichannel automated chamber systems (MCACs) were developed for the continuous monitoring of soil CO2 efflux in forest ecosystems. The MCACs mainly consisted of four modules: eight soil chambers with lids that automatically open and close, an infrared CO2 analyzer equipped with eight multichannel gas samplers, an electronic controller with time-relay circuits, and a programmable logic datalogger. To examine the stability and reliability of the developed MCACs in the field during all seasons with a high temporal resolution, as well as the effects of temperature and soil water content on soil CO2 efflux rates, we continuously measured the soil CO2 efflux rates and micrometeorological factors at the Nam-san experimental site in a Quercus mongolica forest floor using the MCACs from January to December 2010. The diurnal and seasonal variations in soil CO2 efflux rates markedly followed the patterns of changes in temperature factors. During the entire experimental period, the soil CO2 efflux rates were strongly correlated with the temperature at a soil depth of 5 cm (r2 = 0.92) but were weakly correlated with the soil water content (r2 = 0.27). The annual sensitivity of soil CO2 efflux to temperature (Q10) in this forest ranged from 2.23 to 3.0, which was in agreement with other studies on temperate deciduous forests. The annual mean soil CO2 efflux measured by the MCACs was approximately 11.1 g CO2 m-2 day-1. These results indicate that the MCACs can be used for the continuous long-term measurements of soil CO2 efflux in the field and for simultaneously determining the impacts of micrometeorological factors.

The Study on Carbon Budget Assessment in Pear Orchard (배 재배지의 탄소수지 산정에 관한 연구)

  • Suh, Sanguk;Choi, Eunjung;Jeong, Hyuncheol;Lee, Jongsik;Kim, Gunyeob;Lee, Jaeseok;Sho, Kyuho
    • Korean Journal of Environmental Biology
    • /
    • v.33 no.3
    • /
    • pp.345-351
    • /
    • 2015
  • This study was conducted to find out the methodology of carbon budget assessment among soil, atmosphere and plant. Soil respiration, net ecosystem productivity of herbs and net ecosystem productivity of woody plants have been measured in 30 years old pear orchard at Naju. Closed Dynamic Chamber (CDC) method was used to measure soil respiration and net ecosystem productivity of herbs. Net ecosystem productivity of woody plant (pear) was determined by eddy covariance method using the EddyPro (5.2.1) program. As for soil respiration, $429.1mgCO_2m^{-2}h^{-1}$ was released to atmosphere and sensitivity of soil temperature ($Q_{10}$) was 2.3. In case of herbs, respiration was superior to photosynthesis during measurement period. From 20 to 24 Jun 2015, the sum of absorbed and released $CO_2$ by herb's photosynthesis and respiration was $156.1mgCO_2m^{-2}h^{-1}$. Woody plants showed the $680.1mgCO_2m^{-2}h^{-1}$ of absorption by photosynthesis. In a farm scale, the sum of soil respiration, and net ecosystem productivity of herbs and woody plants was $0.04tonCO_2ha^{-1}$ during the measurement period, and it showed that pear orchard act as a $CO_2$ sink. This study using various approaches is expected to present a methodology for evaluating the carbon budget of perennial woody crop plantations.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Effect of Carbon Dioxide Concentration, Temperature, and Relative Drought on Growth Responses and Yield in Spring Potato (Solanum tuberosum L.) (이산화탄소와 온도 그리고 한발 영향에 따른 감자의 생육과 수량반응)

  • Lee, Yun-Ho;Cho, Hyeoun-Suk;Kim, Jun-Hwan;Sang, Wan-Gyu;Shin, Pyong;Baek, Jae-Kyeong;Seo, Myung-Chul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.2
    • /
    • pp.149-158
    • /
    • 2018
  • Agriculture is strongly influenced by climate change such as increased temperature and carbon dioxide ($CO_2$). This study describes the effects of climate change elevated $CO_2$, temperature, and relative drought on growth responses and yield in potato (Solanum tuberosum L.). The assessment was conducted for spring seasons in Soil-Plant-Atmosphere Research (SPAR) chamber at National Institute of Crop Science (NICS). Potatoes exhibit a positive response to $CO_2$ enrichment but water stress primarily reduces potato canopy and tuber yield. Elevated $CO_2$ and temperature increased both dry weight and tuber yield. Elevated $CO_2$ and temperature influenced SPAR 2 plants to a larger, and tuber increased yield up to 28% of than in SPAR 1(30-year average temperature at 450 ppm of $CO_2$). Our study findings indicate that tuber yield increase in potato under high $CO_2$ concentration was due to an increase in the size of individual tubers rather than in the number of the tubers per plant. On other hand, SPAR 3(30-year average temperature $+2.8^{\circ}C$ at 700 ppm of $CO_2$ under water stress) was lower than SPAR 2(30-year average temperature $+2.8^{\circ}C$ at 700 ppm of $CO_2$) nearly 56% of tuber yield due to drought. The results confirm potato drought sensitivity in terms of yield response. The experiment also showed that, in the conditions of climate change, climate change scenarios that improve cropping systems with potato.

하부전극 물질에 따른 CdTe박막 증착과 그에 따른 전기적 특성 평가

  • Kim, Dae-Guk;Sin, Jeong-Uk;Lee, Yeong-Gyu;Kim, Seong-Heon;Lee, Geon-Hwan;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.327-328
    • /
    • 2012
  • 의료분야의 진단 방사선 장비는 초기의 필름방식 및 카세트에서 진보되어 현재는 디지털방식의 DR (Digital Radiography)이 널리 사용되며 이에 관한 연구개발이 활발히 진행 되고 있다. DR은 일반적으로 직접방식과 간접방식으로 나눌 수 있다. 직접방식의 원리는 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 전압을 인가하여 전기장을 유도한 가운데, X선을 조사하면 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이것은 양단에 유도된 전기장의 영향으로 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 하부기판을 통하여 이미지로 변조된다. 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 조사된 X선을 형광체에서 가시광선으로 전환하고, 이를 Photodiode와 같은 광변환소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말한다. 본 연구에서는 직접방식에서 이용되는 광도전체 중 흡수효율이 높고 Mobility가 뛰어난 CdTe를 선정하여 PVD (Physical vapor deposition)방식으로 300 m의 두께를 목표로 하여 증착을 진행하였다. Chamber의 진공도가 $2.5{\times}10^{-2}$ Torr로 도달 시점부터, Substrate와 Boat에 열을 가하였다. Substrate온도는 $350^{\circ}C$, Boat온도는 $300^{\circ}C$도로 설정하여 11시간 동안 진행하였다. Substrate온도는 $303^{\circ}C$, Boat온도는 $297^{\circ}C$도부터 증착이 시작되어 선형적인 증가세 추이를 나타내어 Substrate 및 Boat온도가 설정 값에 도달 하였을 때, $25{\sim}34.4{\AA}/s$ 증착율을 나타내었다. 하부전극의 물질에 따른 CdTe증착 효율성 평가를 진행한 후, 그에 따른 전기적 특성을 알아보았다. 하부전극의 물질로는 ITO (Indium Tin Oxide), Parylene이 코팅 된 ITO, Au, Ag를 사용하였다. 하부전극의 물질 상단에 Thermal Evaporation System을 사용하여 CdTe를 증착한 후, Cdte 상단에 Au를 증착 시켜 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 증착 결과 ITO와 Ag상단에 증착시킨 CdTe박막은 박리가 되었고, Au와 Parylene이 코팅 된 ITO에는 CdTe박막이 안정적이게 형성이 되었다. 이 두 샘플에 대하여 동일한 조건으로 민감도와 암전류를 측정 시, Parylene이 코팅된 ITO를 하부전극으로 사용한 CdTe박막은 0.1021 pA/$cm^2$의 암전류와 1.027 pC/$cm^2$의 민감도를 나타낸 반면, Au를 하부전극으로 사용한 CdTe박막은 0.0381 pA/$cm^2$의 암전류와 1.214 pC/$cm^2$의 민감도를 나타내어 Parylene이 코팅된 ITO보다 우수한 전기적 특성을 나타내었다. 따라서 Au는 CdTe박막 증착 시, 하부전극 기판으로서 뛰어난 특성을 나타내는 것을 알 수 있었다.

  • PDF